Фрагмент инструкции


3. Turning counterclockwise will lower air pressure at outlet. 4. Fully counterclockwise will shut off flow of air completely. Close Open Attach Hose Figure 8 REGULATED OUTLET GAUGE 1. This gauge shows at-a-glance, air pressure at outlet. Air pressure is measured in pounds per square inch (PSI). 2. Be sure this gauge reads ZERO before changing air tools or disconnecting hose from outlet. 2. Pull ring on safety valve and allow to snap back to normal position. Figure 10 ! WARNING Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released. 3. Turn power OFF and clean dust and dirt from motor, tank, air lines and pump cooling fins. TANK DRAINAGE 1. Daily with compressor shut off: Drain moisture from tanks by opening drain cocks underneath end of tanks. 2. There are two drain cocks, one for each tank. Open both by turning counter-clockwise. 3. Tilt unit to drain liquid. Dispose of condensation properly according to all laws and regulations. TANK PRESSURE GAUGE Gauge shows pressure in air receiver indicating compressor is building pressure properly. Release all pressure and disconnect power before making any repair. Maintenance 1. Check compressor for any visible problems, especially check oil level to be sure it is at full line. ! WARNING THERMAL OVERLOAD PROTECTORDrain Tank Operation Daily Monthly MAINTENANCE SCHEDULE Figure 12 Phillips Head Screws Deflector Figure 11 Tilt to drain Drain Cock Drain Cock Filter Figure 9 Open OIL CHANGE 1. Allow compressor to run and warm up oil. 2. Position a pan under pump end of unit. 3. Unplug unit. Remove drain plug, allow oil to collect in pan. Tilt unit to completely drain. 4. Replace drain plug, fill pump to full line on dipstick. Use Chevron synthetic 5W-30, Mobil 1 5W-30 or 0W-30 synthetic motor oil. Using other types of oil will cause starting problems. AIR FILTER MAINTENANCE 1. Locate and remove the two Phillips head screws on the top of the air deflector over the cylinder head of the pump. 2. Lift off cover to expose the air filter. 3. Remove filter. Clean with air blast or soap and water. Replace filter if clogged or damaged. 4. Replace air deflector and screws. Do not operate without air deflector as the pump will overheat and become damaged. Check Oil Level Check Safety Valve Change Oil Clean Air Filter (More often in dusty conditions) This compressor is ! WARNING equipped with a automatic reset thermal overload protector which will shut off motor if it becomes overheated. Motor can automatically restart at any time. Keep away from moving parts at all times. 5 Operating Instructions Oil Lubricated Portable Maintenance (Cont.) To reset, turn unit off, wait until unit cools, and push button on the side of the motor cover. If thermal overload protector shuts motor OFF frequently look for the following causes. 1. Low voltage. 2. Wrong gauge wire or length of extension cord. 3. Low oil level (pump may be 2. Drain tank of moisture. permanently damaged). 3. Disconnect hose and hang open ends 4. Defective capacitor or motor. down to allow any moisture to drain. 5. Lack of proper ventilation. The motor must be ! CAUTION allowed to cool down before reset is possible. STORAGE 1. When not in use, store hose and compressor in a cool dry place. Notes 6 Operating Instructions FP2000, FP2012 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Loss of power or overheating 2. No electrical power 3. Blown fuse 4. Breaker open 5. Thermal overload open 6. Pressure switch bad 1. Check for proper use of extension cord (see CORDS, page 3) 2. Plugged in? Check fuse/breaker 3. Replace blown fuse 4. Reset. Determine why problem happened 5. Motor will restart when cool 6. Replace Motor hums but cannot run or runs slowly 1. Low voltage 2. Wrong gauge wire or length of extension cord 3. Shorted or open motor winding 4. Defective check valve or unloader 5. Unit is cold, oil too thick 6. Low oil level 7. Defective capacitor 1. Check with voltmeter 2. Check gauge chart under Operation for proper gauge wire and cord length 3. Replace motor 4. Replace or repair 5. Use 5W-30 synthetic (Mobil 1) and/or warm up the unit 6. Add oil to full line on dipstick 7. Replace or repair Fuses blow/circuit 1. Incorrect size fuse, circuit overloaded 1. Check for proper fuse, use time-delay fuse. Disconnect breaker trips repeatedly other electrical appliances from circuit or operate compressor on dedicated branch circuit 2. Wrong gauge wire or length of 2. Check gauge chart, under Operation extension cord 3. Defective check valve or unloader 3. Replace or repair 4. Low oil level 4. Add oil to full line on dipstick Thermal overload 1. Low voltage 1. Check with voltmeter protector cuts out 2. Clogged air filter 2. Clean filter (see Maintenance section) repeatedly 3. Lack of proper ventilation/room 3. Move compressor to well ventilated area temperature too high 4. Wrong gauge wire or length of 4. Check gaug...

Эта инструкция также подходит к моделям:
Насосное оборудование - FP2000 (3.85 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории