Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Quincy Compressor, модель Air Compressor

Производитель: Quincy Compressor
Размер: 258.7 kb
Название файла: 4e6cfcd6-fae8-4316-957e-78f3045d33c7.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Direct Vent Addendum - Oil For use in conjunction with B-10, or SG atmospheric venting manuals QHT DV– OIL DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS VAPORS • Do not try to light any appliance • Do not touch any electric switch; do not use any phone in you r building • Immediately call your gas supplier from a neighbors phone. • If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer, service agency or the gas supplier. Please Read Instructions Carefully Save for Future Reference If the information in this manual is not followed exactly, a fire explosion may result causing property damage, personal injury or loss of life. DANGER WARNING QUINCY HYDRONIC TECHNOLOGY, INC. 3560 LAFAYETTE RD PORTSMOUTH, NH 03801 PHONE: 603-334-6400 FAX: 603-334-6401 REV. F TABLE OF CONTENTS QHT INC. OIL DIRECT VENT PACKAGES Important Info & Warnings General Information & Installation Explosions Vent System Installation External Clearances Clearances to Combustibles DVH-5 System Installation of Make-up Air Burner Setup Installations B-10 Burner Setup SG Burner Setup Wiring System Start Up Installation Inspection Service and Maintenance Installer and Customer Notes Section Page 1-3 1 4-5 2 6 6 7 2.1 8 2.2 9 3 10 3.1 11 3.2 12 4 13-17 5 18-19 6 19 7 20 IMPORTANT INFORMATION ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL PLUMBING, HEATING AND ELECTRICAL CODES AND ORDINANCES, AS WELL AS THE REGULATIONS OF THE SERVING ELECTRICAL, WATER AND GAS UTILITIES. All systems should be designed by competent contractors, and only persons knowledgeable in the layout and installation of heating systems should attempt the installation of any boiler. It is the responsibility of the installing contractor to see that all controls are correctly installed and operating properly when the installation is completed. Do not burn volatile garbage, gasoline, naphtha or other flammable liquids other than No. 2 fuel oil. All flammable liquids (especially gasoline), chemicals, rags, paper, wood scraps, debris, etc., should be kept away from the boiler at all times. Keep the boiler area clean and free of all fire hazards. Please read the literature and warranties supplied by the manufacturers of the various accessory equipment. This equipment is warranted by the respective manufacturers, not by Quincy Hydronic Technologies, Inc. Each piece of equipment must be installed and used according to the recommendations of the manufacturer. Codes and Regulations: Installation of the boiler, burner, oil tank and related equipment must conform to national, state and local regulating agencies and codes applicable to the installation of the equipment. In the absence of local requirements, the following codes apply: A. ANSI/NFPA - #31 Installation of Oil Burning Equipment B. ANSI/NFPA - #70 National Electric Code C. ANSI/NFPA - #211 Chimneys and Vents D. ANSI/NFPA - #Z223.1 National Fuel Gas Code E. ANSI/NFPA - Domestic Gas Conversion Burner F. CAN/CGA B149 The above codes are available from: National Fire Protection Association (NFPA) Battery March Park Quincy, Massachusetts 02269 OR American Gas Association (AGA) Pleasant Valley Road Cleveland, OH 44134 OR HTTP://1 WARNING • • • • • • • • ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL PLUMBING, HEATING AND ELECTRICAL CODES AND ORDINANCES, AS WELL AS THE REGULATIONS OF THE SERVING ELECTRICAL, WATER AND GAS UTILITIES. Improper installation, adjustment, or maintenance of this boiler can cause property damage, personal injury or death. Due to this fact only experienced technicians and installers may install or adjust BIASI boilers. All systems should be designed by competent contractors, and only persons knowledgeable in the layout and installation of heating systems should attempt the installation of any boiler. The homeowner should never tamper with any part of the boiler. Thoroughly read and understand all instructions including the B-10 or SG atmospheric venting instructions before beginning this installation. After installation place this manual in a safe place in plain view of the boiler. If the manual is no longer legible contact QHT I NC. for a new manual. After the boiler is installed and in working order, it should be serviced once a year before each heating season. Service on the boiler may only be done by an experienced installer or oil heating technician. These boilers may only be direct vented using approved venting systems supplied through QHT INC. For the boiler warranty, please consult the B-10 or SG atmospheric venting manual. Do not burn volatile garbage, gasoline, naphtha or other flammable liquids other than No. 2 fuel oil. All flammable liquids (especially gasoline), chemicals, rags, paper, wood scraps, debris, etc., should be kept away from the boi...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории