Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Dimplex, модель SI 21CS

Производитель: Dimplex
Размер: 1.19 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


5CS bis .. 17CS 30 12.4.3 Terminal Diagram .. 5CS to .. 17CS 31 12.4.4 Legend .. 5CS to .. 17CS 32 12.4.5 Control .. 21CS 33 12.4.6 Load .. 21CS 34 12.4.7 Terminal Diagram .. 21CS 35 12.4.8 Legend .. 21CS 36 12.5 Hydraulic Block Diagram 37 12.6 EC Declaration of Conformity 38 12.7 Warranty Certificate 39 11 APPENDIX: 12.1 DIMENSIONED DRAWINGS 12.1.1 Dimensioned Drawing .. 5CS - 14CS Heating water supplyHeat pump outletHeating water returnHeat pump inlet Heat source supplyHeat pump outletHeat source returnHeat pump inlet Connections on heating side1" internal / 1" external threadConnections on heat source side1 1/4" internal / 1 1/4" external thread 12 APPENDIX: 12.1 DIMENSIONED DRAWINGS 12.1.2 Dimensioned Drawings .. 17CS - 21 CS Heating water returnHeat pump inletHeating water supplyHeat pump outlet Heat source supplyHeat pump outletHeat source returnHeat pump inlet Connections on heating side1 1/4" internal / 1" external threadConnections on heat source side1 1/2" internal / 1 1/2" external thread 13 APPENDIX: 12.2 EQUIPMENT DATA Equipment Data EQUIPMENT DATA for brine-to-water heat pumps for heating purposes1 TYPE AND COMMERCIAL DESCRIPTION ..5CS ..7CS ..9CS ..11CS ..14CS ..17CS ..21CS 2 MODEL 2.1 Enclosure type acc. to EN 60 529 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 2.2 Installation site indoors indoors indoors indoors indoors indoors indoors 3 PERFORMANCE DATA3.1 Operating temperature limits:Heating water supply °C Brine (heat source) °C Antifreeze agentMinimum brine concentration (-13°C freezing temperature) max. 55-5 to +25monoethylene glycol0,25 max. 55-5 to +25monoethylene glycol0,25 max. 55-5 to +25monoethylene glycol0,25 max. 55-5 to +25monoethylene glycol0,25 max. 55-5 to +25monoethylene glycol0,25 max. 55-5 to +250,25 max. 55-5 to +250,25 3.2 Heating water temperature spread at B0 / W35 K 10,1 9,9 10,5 10,1 9,6 9,3 11,3 3.3 Heating capacity / coeff.of perform. at B-5 / W55 1) kW / --at B0 / W50 1) kW / --at B0 / W35 1) kW / --3,8 / 1,964,8 / 2,755,3 / 4,3 5,6 / 2,26,7 / 2,96,9 / 4,3 7,7 / 2,39,0 / 3,19,2 / 4,4 9,4 / 2,411,3 / 3,011,8 / 4,4 12,5 / 2,614,2 / 3,414,5 / 4,5 14,4 / 2,616,7 / 3,217,1 / 4,6 17,9 / 2,520,4 / 3,121,1 / 4,3 3.4 Sound power level dB(A) 54 55 56 56 56 58 59 3.5 m./h / PaHeating water flow rate at internal pressure difference 0,45 / 2000 0,6 / 2500 0,75 / 4500 1,0 / 3500 1,3 / 3500 1,5 / 4000 1,6 / 6000 3.6 Brine flow rate at internal pressure difference (heat source) m./h / Pa 1,2 / 6500 1,7 / 10000 2,3 / 16000 3,0 / 13000 3,5 / 13000 3,8 / 9000 6,0 / 12000 3.7 Refrigerant; total charge weight Type / kg R407C / 1,7 R407C / 1,5 R407C / 1,8 R407C / 2,0 R407C / 2,3 R407C / 2,8 R407C / 4,5 4 DIMENSIONS; CONNECTIONS AND WEIGHT4.1 Equipment dimensions without connections 4) H x W x L mm 800 . 600 . 500 800 . 600 . 500 800 . 600 . 500 800 . 600 . 500 800 . 600 . 500 1380 . 600 . 500 1380 . 600 . 500 4.2 Equipment connections for heating system inches thread 1" i/ext. thread 1" i/ext. thread 1" i/ext. thread 1" i/ext. thread 1" i/ext. 4.3 Equipment connections for heat source inches thread 1." i/ext. thread 1." i/ext. thread 1." i/ext. thread 1." i/ext. thread 1." i/ext. thread 1." i/ext. 4.4 Weight of transport unit(s) incl. packaging kg 131 133 134 145 157 165 215 5 ELECTRICAL CONNECTION5.1 Nominal voltage; fusing V / A 400 / 16 400 / 16 400 / 16 400 / 16 400 / 16 400 / 16 400 / 20 5.2 Nominal power consumption 1) B0 W35 kW 1,23 1,6 2,07 2,66 3,22 3,72 4,91 5.3 Starting current with soft starter A 22 (w/out soft st.) 30 (w/out soft st.) 15 26 26 27 29 5.4 Nominal current B0 W35 / cos. A / --2,22 2,89 3,77 4,84 5,81 6,35 8,86 6 COMPLIES WITH EUROPEAN SAFETY REGULATIONS 3) 3) 3) 3) 3) 3) 3) 7 OTHER DESIGN CHARACTERISTICS7.1 Water inside equipment protected against freezing 2) ja yes yes yes yes yes yes 7.2 Performance settings 1 1 1 1 1 1 1 7.3 Controller internal / external internal internal internal internal internal internal internal 1) 2)4) 3) See EC Declaration of ConformitySubject to technical modifications Issued 24.03.2004 These data characterize the size and performance capability of the system. For economic and energetic reasons, additional factors such as balancepoint and control need to be taken into consideration. Abbreviations have the following meaning, e.g. B10 / W55: heat source temperature 10 °C andheating water supply temperature 55 °C. The heating circulating pump and the controller of the heat pump must be ready for operation at all times.Please keep in mind that morer space is required for pipe connection, operation and maintenance. 14 APPENDIX: 12.3 PERFORMANCE CURVES/PRESSURE LOSSES 12.3.1 Performance Curves .. 5CS 0 2 4 6 8 10 12 14 16 0 1 2 3 4 5 6 7 8 0 1 2 3 4 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 Heating capacity in [kW] Water outlet temperature in [ Conditions: Heating water flow rate 0,45 m3/h Brine flow rate 1,2 m3/h COP in the heating mode (incl. proportional pump energy) Power consumption (incl. proportional pump power input) Brine...

Эта инструкция также подходит к моделям:
Насосное оборудование - SI 11CS (1.19 mb)
Насосное оборудование - SI 14CS (1.19 mb)
Насосное оборудование - SI 17CS (1.19 mb)
Насосное оборудование - SI 5CS (1.19 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории