Инструкция по эксплуатации Campbell Hausfeld, модель FP202900

Производитель: Campbell Hausfeld
Размер: 865.63 kb
Название файла:

Язык инструкции:enesfr

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


A large amount of fast moving air will be released when the safety valve is opened with pressure in the tank. Wear ANSI approved Z87.1 safety glasses. 2. Drain moisture from tank by opening drain valve underneath tank. Tilt tank to remove all moisture. 3. Clean dust and dirt from tank, air lines and pump cover while compressor is still OFF. ASME SAFETY VALVE Do not remove or attempt to adjust the safety valve! Check the safety valve by performing the following steps: 1. Plug the compressor in and run until shut off pressure is reached. 2. Wearing safety glasses, pull the ring on the safety valve to release pressure from compressor tank. Use your other hand to defl ect fast-moving air from being directed toward your face. 3. The safety valve should automatically close at approximately 40 psi - 50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced. DRAIN TANK With compressor shut off and pressure released, drain moisture from tank by opening drain valve underneath tank. CLEANING Turn power OFF and clean dust and dirt from pump cover, tank, and air lines. IMPORTANT: Unit should be located as far from spraying area as hose will allow to prevent over-spray from clogging air filter. LUBRICATION. This is an oilless type compressor requiring no lubrication. OVERLOAD PROTECTOR This compressor is equipped with a manual reset overload protector which will shut off motor if it becomes overloaded. If overload protector shuts motor OFF frequently, look for the following causes. 1. Low voltage. 2. Clogged air fi lter. 3. Lack of proper ventilation. If the overload protector is actuated, the motor must be allowed to cool down for 30 minutes before manual resetting. END OF OPERATION/STORAGE 1. Turn ON / OFF switch to the OFF position. 2. Unplug power cord from wall outlet and wrap around handle area to prevent damage when not in use. 3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast moving air from being directed toward your face. 4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank. 5. Air hose should be disconnected from compressor and hung open ends down to allow any moisture to drain. 6. Compressor and hose should be stored in a cool, dry place. TECHNICAL SERVICE For information regarding the operation or repair of this product, please call 1-800-543-6400. MAINTENANCE SCHEDULE OPERATION DAILY WEEKLY MONTHLY DRAIN TANK . CHECK SAFETY VALVE . CLEAN UNIT . Figure 5 5 Operating Instructions and Parts List FP202800, FP202900 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Switch in OFF position 1. Make sure compressor is plugged in and switch is ON. 2. No electrical power at wall outlet 2. Check circuit breaker or fuse at electrical panel. 3. Compressor has reached automatic 3. Release air from tank until compressor restarts automatically. shutoff pressure 4. Motor overheated 4. Allow compressor to cool for approximately 30 minutes so thermal overload switch will reset. Make sure compressor is run in a clean, well-ventilated area. 5. Pressure switch bad 5. Replace pressure switch. Thermal overload protector cuts out repeatedly 1. Low voltage 2. Wrong gauge wire or length of extension cord 3. Clogged intake filter 4. Lack of proper ventilation/room temperature too high 5. Defective check valve 6. Defective unloader valve (on pressure switch) 7. Compressor valves failed 1. Check voltage at wall outlet with voltmeter. 2. Check extension cord chart for proper extension cord usage. 3. Clean or replace filter. 4. Move compressor to well-ventilated area. 5. Repair or replace. 6. Repair or replace. 7. Replace valve assembly. Do not disassemble check valve with air pressure in tank; bleed tank. Tank pressure drops when compressor shuts off 1. Loose drain valve 2. Check valve leaking 1. Tighten. 2. Remove check valve. Clean or replace. 3. Loose connections at fittings, tubing, etc. 3. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble. 4. Tank leaks 4. Check tank for leaks with soap and water solution. If leak is detected, tank must be replaced with genuine replacement part. Do not disassemble check valve with air pressure in tank; bleed tank. Compressor runs continuously and air output is lower than normal/low discharge pressure 1. Excessive air usage, compressor too small 2. Clogged intake filter 3. Loose connections at fittings, tubing, etc. 1. Decrease usage or purchase unit with higher air delivery (SCFM). 2. Clean or replace. 3. Check all connections with soap and water solution. If a leak is detected, (1) tighten or (2) remove fitting and apply pipe tape to threads and reassemble. 4. Tank leaks 4. Check tank for leaks with soap and wat...

Эта инструкция также подходит к моделям:
Насосное оборудование - FP202800 (865.63 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории