Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Little Giant Ladder, модель VCMA-10

Производитель: Little Giant Ladder
Размер: 162.28 kb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


TO REDUCE THE RISK OF ELECTRICAL SHOCK, BE CERTAIN THAT IT IS CONNECTED TO A PROPERLY GROUNDED GROUNDING TYPE RECEPTACLE. IN ANY INSTALLATIONS WHERE PROPERTY DAMAGE AND/OR PERSONAL INJURY MIGHT RESULT FROM AN INOPERATIVE OR LEAKING PUMP DUE TO POWER OUTAGES, DISCHARGE LINE BLOCKAGE, OR ANY OTHER REASON, A BACKUP SYSTEM(S) AND/OR ALARM SHOULD BE USED. SUPPORT PUMP AND PIPING WHEN ASSEMBLING AND WHEN INSTALLED. FAILURE TO DO SO MAY CAUSE PIPING TO BREAK, PUMP TO FAIL, MOTOR BEARING FAILURES ETC. INSTALLATION 1. Carefully unpack the pump. Remove the cardboard packing from the motor cover air slots. Carefully slide the packing away from the pump. This packing is used to prevent switch move- ment during shipment (Figure 1). INTRODUCTION 2. Mounting the pump: the tank has two slots pro- vided to mount the unit. The slots are located on the ends of the tank (Figure 5). The unit should be mounted either on the side of the air condi- tioner unit or nearby wall. Pump must be level and the inlet must be below the coil drain. Conduit fittings are not compati- ble with the plastic pump housing. 3. The pump should not be installed in a manner that will subject it to splashing or spraying. 4. This pump is not intended for use inside air plenums. ELECTRICAL CONNECTIONS 1. Shut off electrical power at fuse box before making any connec- tions. All wiring must comply with local codes. 2. Line voltage: Connect power cord to line voltage specified on motor and nameplate. Power cord must be connected to a constant source of power (not a fan or other device that runs intermittently). If power cord does not have a plug, wiring is as follows: green (or green/yellow)—ground. Black (or brown)— line. White (or blue)—neutral. 3. Safety switch: The safety overflow switch should be connected to a class II low voltage circuit. To control a thermostatic circuit the COM and NO connections from the safety switch are to be wired in series with the low voltage thermostat circuit to shut down the heating/AC circuit. The COM and NC switch contacts may be used to actuate a low voltage alarm circuit (connected in series) if the heating/cooling system can not be disrupted. The safety switch comes from the factory with leads connected to the COM and NO switch terminals. Typical hook-up of “NC” circuits would be (Figures 2 & 3). 4. If fused plug is used on 230V units, a 1.0 amp fuse is recom- mended. Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. PIPING 1. Run flexible tubing or pipe from evaporator drain into one of the three pump inlets. Be sure inlet piping is sloped downward to allow gravity flow (Figure 4). Extend the inlet piping into the tank from 1 to 3 inches to ensure that it will not interfere with proper float operation. Be sure that the inlet piping is cut at an angle where it enters the tank. 2. The outlet piping should be flexible tubing secured with a hose clamp (not provided) or pipe (3/8 inch I.D. maximum to prevent excessive flow back to unit). From condensate unit, e...

Эта инструкция также подходит к моделям:
Насосное оборудование - CURP-20ULS (162.28 kb)
Насосное оборудование - VCMA-15 (162.28 kb)
Насосное оборудование - VCMA-20 (162.28 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории