Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Delta, модель D25886

Производитель: Delta
Размер: 3.2 mb
Название файла: 2af454a8-518e-485c-b5d4-dd7c41a824b6.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


The valve can then be removed, cleaned, then reinstalled. 8. Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped) 9. Store the air compressor in a clean and dry location. D25886 16- ENG TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION Excessive tank Pressure switch does not Move On/Auto/Off lever to pressure - safety shut off motor when the “OFF” position, if the valve pops off. compressor reaches “cutout” pressure. Pressure switch “cut-out” too high. outfit does not shut off contact a Trained Service Technician. Contact a Trained Service Technician. Air leaks at Tube fittings are not tight Tighten fittings where air can fittings. enough. be heard escaping. Check fittings with soapy water solution. Do Not Overtighten. Air leaks at pressure switch release valve. (if equipped) Defective pressure switch release valve. Contact a Trained Service Technician. Air leaks in air tank or at air tank welds. Air leaks between head and valve plate. Defective air tank. Leaking seal. Air tank must be replaced. Do not repair the leak. Do not drill into, weld or otherwise modify air tank or it will weaken. The tank can rupture or explode. Contact a Trained Service Technician. Air leak from Possible defect in safety Operate safety valve manually safety valve. valve. by pulling on ring. If valve still leaks, it should be replaced. Knocking Noise. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. 17- ENG D25886 PROBLEM CAUSE CORRECTION Pressure reading on the regulated pressure gauge drops when an accessory is used. It is normal for “some” pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the “Description of Operation” paragraph in the “Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). Compressor is Prolonged excessive use of Decrease amount of air not supplying air. usage. enough air to operate Compressor is not large Check the accessory air accessories. enough for air requirement. Hole in hose. Check valve restricted. Air leaks. requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Check and replace if required. Remove and clean, or replace. Tighten fittings. Regulator knob has continuous air leak. Damaged regulator Replace Regulator will not shut off air outlet. Damaged regulator Replace D25886 18- ENG PROBLEM CAUSE CORRECTION Motor will not Fuse blown, circuit breaker Check fuse box for blown run. tripped. fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. You should use a time delay fuse. Check for low voltage problem. Check the extension cord. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. Check the extension cord. length or gauge. Extension cord is wrong Check wiring connection connections. Loose electrical inside terminal box. Have checked by a Trained Service Technician. Faulty motor. 19- ENG D25886 D25886 20- ENG AIR COMPRESSOR DIAGRAM 21 5 13 16 4 3 9 10 1 11 15 6 14 12 8 7 7 17 20 18 19 2 PARTS LIST Key No Part Number Description 97503734 Safety Valve SS-2707 Drain Valve CAC-4299 Wheel 6" (2 used) CAC-60 Shoulder Bolt (2 used) SSF-8080-ZN Nut Hex 3/8-16 (2 used) AC-0345 Handle SSF-612 Screw #10-16 x 1(2 used) AC-0364 Molded Foot Bumper Z-AC-0353-1 Pressure Switch SUDL-413-2 Cord Assembly AC-0027-2 Manifold SSP-480 Nipple 1/4-18 NPT x 2.50 D21426 Regulator Z-AC-0009-1 Gauge - Right Hand Z-AC-0010-1 Gauge - Left Hand Z-D25895 Tank SSP-473 Nut Sleeve D24879 Check Valve SSP-490-1 Bushing * CAC-1254 Isolator (4 used) * SSF-621 Screw 1/4-14 x .625 (2 used) 21- ENG D25886 D25886 22- ENG AIR COMPRESSOR PUMP DIAGRAM 1 15 20 16 14 9 12 7 10 4 11 13 8 6 5 3 21 2 18 PARTS LIST Key No Part Number Description 1 D25734 Shroud, Left 2 AC-0470 Shroud, Right 3 CAC-1196 Cylinder Head 4 * CAC-1212 Tube Seal 5 * CAC-1199 Gasket Head 6 Z-D24985 Valve Plate Assembly 7 DAC-269 Outlet Tube 8 * SSG-8169 O-ring 9 + ————— Rod Assembly 10 CAC-1206-1 Clamp 11 AC-0206 Isolator Tube 12 x SSF-3147 Screw 3/8-16 x .375 13 + ————— Cylinder Sleeve 14 ————— Endbell Assembly 15 x SUDL-9-1 Screw 8-32x .375/.344 16 AC-0815 Timing Belt 18 x SSF-3156 Screw, 10-9x.50 Plastite (5 used) 20 * D24731 Pump Isolator (5 used) 21 x SSF-995 Screw #10-24 x .875 (4 used) Not Shown D20111 Motor Cord Kits Available * K-0387 Isolator ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории