|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be transmitted as a Parameter Change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0011nnnn 3n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00000110 06 DM2000 ADDRESS 00000011 03 Setup memory 0eeeeeee ee Element No. (If ‘ee’ is 0, ‘ee’ is expanded to two bytes) 0ppppppp pp Parameter No. 0ccccccc cc Channel No. EOX 11110111 F7 End of exclusive 12.3.12 Parameter change (Backup memory) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be controlled. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00000110 06 DM2000 ADDRESS 00000100 04 Backup memory 0aaaaaaa ee Element No. 0aaaaaaa pp Parameter No. 0ccccccc cc Channel No. DATA 0ddddddd dd Data :: EOX 11110111 F7 End of exclusive 12.3.13 Parameter request (Backup memory) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the value of the specified parameter will be transmitted as a Parameter Change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0011nnnn 3n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00000110 06 DM2000 ADDRESS 00000100 04 Backup memory 0aaaaaaa ee Element No. 0aaaaaaa pp Parameter No. 0ccccccc cc Channel No. EOX 11110111 F7 End of exclusive 12.3.14 Parameter change (Function call Library: store/recall) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the specified memory/library will be stored/recalled. Transmission If [Parameter change ECHO] is ON, this message will be retransmitted without change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00000110 7F Universal ADDRESS 00010000 10 Address UU 00ffffff ff Address UL (function) 0aaaaaaa aa Address LU (number H) 0aaaaaaa aa Address LL (number L) DATA 0ddddddd dd channel High 0ddddddd dd channel Low EOX 11110111 F7 End of exclusive function number channel*1) tx/rx SCENE RECALL 0x00 0-99 256 tx*2)/r x EQ LIB RECALL 0x01 1-200 0-513 tx/rx GATE LIB RECALL 0x02 1-128 0-95 tx/rx COMP LIB RECALL 0x03 1-128 0-513 tx/rx EFF LIB RECALL 0x04 1-128 0-7 tx/rx GEQ LIB RECALL 0x05 0-128 0-5 tx/rx CHANNEL LIB RECALL 0x06 0-128 0-513 tx/rx INPATCH LIB RECALL 0x07 0-32 256 tx/rx OUTPATCH LIB RECALL 0x08 0-32 256 tx/rx Bus to Stereo LIB RECALL 0x09 0-32 256 tx/rx Surround Monitor LIB RECALL 0x0A 0-32 256 tx/rx AUTOMIX LIB RECALL 0x0B 1-16 256 tx/rx SCENE STORE 0x20 1-99 256, 16383 tx/rx EQ LIB STORE 0x21 41-200 0-513, 16383 tx/rx GATE LIB STORE 0x22 5-128 0-96, 16383 tx/rx COMP LIB STORE 0x23 37-128 0-513, 16383 tx/rx EFF LIB STORE 0x24 53-128 0-7, 16383 tx/rx GEQ LIB STORE 0x25 1-128 0-5, 16383 tx/rx CHANNEL LIB STORE 0x26 3-128 0-513, 16383 tx/rx INPATCH LIB STORE 0x27 1-32 256, 16383 tx/rx OUTPATCH LIB STORE 0x28 1-32 256, 16383 tx/rx Bus to Stereo LIB STORE 0x29 1-32 256, 16383 tx/rx Surround Monitor LIB STORE 0x2A 1-32 256, 16383 tx/rx AUTOMIX LIB STORE 0x2B 1-32 256, 16383 tx/rx *1) 0:CH1 - 95:CH96, 128:BUS1 - 135:BUS8, 256:AUX1 267: AUX12, 384:MATRIX1L - 391:MATRIX4R, 512:STEREO L - 513:STEREO R DM2000—Manual de Instrucciones Format Details 337 Format Details 337 *2) This is also transmitted when a program that has not been assigned to the [Program change table] is recalled. (Normally this would be transmitted as a program change message.) 12.3.15 Parameter change (Function call: title) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the title of the specified memory/library will be changed Transmission In response to a request, a Parameter Change message will be transmitted on the [Rx CH]. If [Parameter change ECHO] is ON, this message will be retransmitted without change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00000110 7F Universal ADDRESS 00010000 10 Function ca...