Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Roland, модель SRV-330

Производитель: Roland
Размер: 582.84 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


18.1993 Version :1.00 1.RECOGNIZED RECEIVE DATA CHANNEL VOICE MESSAGE Note On Status Second_ Third SYSTEM EXCLUSIVE MESSAGE 9nH IckH n = MIDI Channel kk = Note Number w = Velocity vvH OH-FH (ch.l - ch.16) 00H-7FH (0- 127) 01H-7FH (1 -127) Real time control of parameter is possible by assigning a note number or velocity to that parameter Control Change Status Second BnH ccH n « MIDI Channel cc = Control Number Third wH OH-FH (ch.l - ch.l6) ООН - 1 FH,20H-3FH (0 - 31,32 - 63) 40H •• 5FH (64-95) ООН-7FH (0-127) w » Control Value Real time control of parameter is possible by assigning a control changeto that parameter Program Change Status Second CnH ppH n = MIDI Channel pp = Program Number OH-FH (ch,1 -ch 16) 00H - 7FH (prog. 1 - prog 128) The program number of internal memory, that corresponds to the received program number, can be called. Channel pressure Status Second DnH wH n = MIDI Channel w = Pressure Value OH-FH (ch .1 - ch.16) 00H-7FH (0-127) Real time control of a parameter is possible by assigning the channel pressure to that parameter Pitch Bend Change Status_Second EnH 1ÏÏT n = MIDI Channel Il = Data LSB mm = Data MSB Third mmH OH-FH (ch.l - ch.16) ООН-7FH (0-127) 00H-7FH (0-127) Rea! time control of a parameter is possible by assigning the pitch bender to that parameter. SYSTEM EXCLUSIVE MESSAGE Status FOH F7H System Exclusive EOX (End of Exclusive) For more details, please refer to "3 EXCLUSIVE COMMUNICATIONS* and "Roland Exclusive Messages" 2.TRANSMITTED DATA 2.1.BYPASS MESSAGE Whole messages bypassed, transmitted to MIDI OUT by setting System Parameter 'MIDI THRU' to 'ON'. 2.2.GENERATED MESSAGE CHANNEL VOICE MESSAGE Control Change Status Second Third BnH ccH n = MIDI Channel cc = Control Number w = Control Value wH OH-FH (ch.l - ch.16) ООН -1FH (0 - 31), 40H - 5FH (64 - 95) ООН - 7FH (0 - 127) Transmit value of Pedal connecting EXP Pedal JACK with Control Number by setting System Parameter 'TX Exp Pedal', Status FOH F7H System Exclusive EOX (End of Exclusive) For more details, please refer to "3 EXCLUSIVE COMMUNICATIONS" and "Roland Exclusive Messages", ¿.EXCLUSIVE COMMUNICATION Via Exclusive Messages, SRV-330 can send or receive parameter setting data in conjunction with external MIDI devices, Exclusive communications of SRV-330 are always conducted under the following One way communication format (shown as the Roland Exclusive Format type IV) For more details, please refer to "Roland Exclusive Messages" in this Manual, For the Model ID, SRV-330 accepts 59H, For the Device ID, numerals one unit lower than Receive MIDi number are used Request Datai RQ1 (11H) FOH Exclusive status 41H Manufacturer ID (Roland) Dev Device ID (Dev:00H •• OfH) 59H Model ID (SRV-330) 11H Command ID (RQ1) aaH Address MSB bbH Address ccH Address LSB ssH Size MSB ttH Size uuH Size LSB sum Checksum F7H EOX (End of System Exclusive) •SRV-330 dose not transmit this message Data Sett DT1 (12H) Byte Description FOH Exclusive status 41H Manufacturer ID (Roland) Dev Device ID (Dev:00H - OFH) 59H Model ID (SRV-330) 12H Command ID (DTD aaH Address MSB bbH Address ccH Address LSB ddH Data eeH Data sum Checksum F7H EOX (End of System Exclusive) 4.ADDRESS MAPPING OF PARAMETERS The address and size are displayed under 7-bit hexadecimal notation. Address _ MSB LSB Binary Oaaa aaaa 7-bit Hexadecimal AA Address MSB ОЬЬЫэЬЬЬ Occc cccc BB CC LSB Binary Osss ssss 7-bit Hexadecimal SS Ottt tut Ouuu uuuu UU Parameter base address The actual address of each parameter is the start address of the block plus the offset address There are two type of the SRV-330 exclusive message One is an individual parameter communication, the other is a bulk dump communication In bulk dump communication, SRV-330 needs EOB(End Of Bulk Mark) end of communication In individual parameter communication, One system exclusive message "FQ F7" can only have one parameter You cannot use any address having "#" for the top address in a system exclusive message Printed in Japan -l- SRV-330 MIDI Implementation Address Block Map Address Block Sub Block Note I Program No, 100 I Parameters I Early Reflection I and Ambiance Table I End Of Bulk Mark 10 00 ООН 10 08 ООН SYSTEM PARAMETERS PROGRAMS PARAMETERS Prograro No, 1 Parameters Individual Individual Program No.100 Parameters 20 00 00H 20 01 ООН 20 02 ООН 20 03 ООН TEMPORARY BUFFER DISPLAY DATA PANEL INFORMATION Individual Individual Individual Indi viduaI Table-1. SYSTEM PARAMETERS 00 01 02H# 0000_pppp8 Program Change Map No„1 00 01 03H# 0000_ppppB Program Change Map No, 1 LS8 00 00 00H ^-у. 1 SYSTEM 1 1 PARAMETERS I ^-к Bulk 00 04 7CH 00 04 7DH 00 04 7EH 00 04 7FH# 0000_ppppB 0000_pppp8 0000_pppp8 0000_pppp8 Program Change Program Change Program Change Program Change 00 08 ООН 1 PROGRAMS 1 1 PARAMETERS I 1 Program No, 1 I Parameters H- 1 Bulk...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории