Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Roland, модель SPA-120

Производитель: Roland
Размер: 1.57 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


After about 3 or 4 seconds, the protection circuit deactivates and the amplifier can be used. • Make sure that the power switch is off before making or breaking connections to this unit or before moving it. • Allow plenty of air space in front of and behind the amplifier for cooling. • When using more than two SPA amplifiers, we recommend using a fan for cooling. • Do not open this unit. • When replacing the fuse, replace only with the value indicated over the fuse holder. • If it is desireable to remove the rubber feet on the bottom of this unit, remove the feet and replace the screws. • Unplug this unit when it is not to be used for a long period of time. Unplug by grasping the plug rather than pulling on the cord. • In case of trouble, unplug this unit immediately and contact your nearest Roland dealer. • To clean this unit, unplug it and wipe it with a cloth dampened with a neutral cleaner. Do not use solvents such as paint thinner. before Making Connections Make sure speaker power rating and mpedance match your amplifier, lit is possible to destroy the speakers f the maximum input level of the speakers is lower than the maximum output of the amplifier. ^Required speaker impedances: Stereo operation: 40 or more Vlono operation: 80 or more SPA-240 Connections For Stereo Operation Make sure the power switch is off before connecting the speakers. Also, make sure all system volume controls are set at minimum. SPA-120 Connections For Stereo Operation OPERATION SPA-240 SPA-120 m # % i- (OHO INPUT-—•- CÜ * -m-© <§) 0 --—OUTW 0— 4-16 ohm SPE - ©00 ftKERS i) (k ) © (0) -INp « STEREC ■ UT-- ATT p .....m{m (f| © --OUT © — 4-16 ohm Dyj-— ,, Q) SPEAKERS 1. Make the connections to the SPA amplifier and set the MODE switch @@ at STEREO or MONO, as needed. 2. Check the speaker connections to make sure they are correct. When operating in stereo, double check that the polarity (" + ", " — ") of the speaker connections is correct. 3. Turn the SPA POWER switch on. 4. Set the level of the input sound source to the desired listening level. 5. When using a high level sound source, use the attenuators on the rear panel@(b)to lower the input level. 3 MAMES AND FUNCTIONS OF PARTS îPA-240 FRONT PANEL SPA-120 FRONT PANEL POWER INDICATOR . POWER INDICATOR- POWER SWITCH - SPA-240 REAR PANEL MODE Switch Determines the operating mode of the amplifier, *ln MONO, use Channel A for the input. Note that the speaker connections for MONO mode are not the same as for STEREO mode. D INPUT ATTENUATOR Control I SPA-240 only) Controls the input level. •At "0”, a +4dBm (1.23v RMS) input signal will produce the maximum rated power output. b) INPUT ATTENUATOR Switch (SPA-120 only) For attenuating the input level by 20dB. •At "0", a +4dBm (1.23v RMS) input signal will produce the maximum rated power output. •Affects both channels simultaneously. 3)©iNPUT CONNECTORS •The balanced input uses an XLR connector; the unbalanced input a standard 1/4" phone jack. • If both inputs (balanced and unbalanced) are used simultaneously, the unbalanced input will have priority. ©@SEND Jack This jack is for cascading amplifiers when more than one is being used. ©©SPEAKER BINDING POSTS ©SPEAKER Jack (SPA-120 only) •The. SPEAKER jacks ©are in parallel with the SPEAKER BINDING POSTS ©; use caution when using simultaneously. ©(g) GROUND Screw For making common ground connections with other equipment, @(h) FUSE 4 BTL Connection For Mono Operation MODE MONO (BTL) ¡n 9 st’ MODE MONO(BTL) ¿là 1-16 ohm SPEAKERS o Use balanced or unbalanced inputs. If both are used, the unbalanced will have priority. SPA-120 SPA-240 Use speaker of 80 to 16Q. The maximum rated power output cannot be obtained with a speaker of less than 8fi because a low impedance speaker would activato the protection circuit. Mono 2ch Out MODE input STEREO- With the CH A SEND connected to the CH B INPUT, the amplifier connections are the same as for STEREO mode. Two channel mono operation cannot be obtained with the MODE switch in the MONO position. Paralel connection in MONO (To increase power output for PA system use) - " éf- $jf- r- Under certain conditions, the use of a cooling fan is recommended Li & & MODE MONO (BTL) 'SPEAKER 8 Q (R. M. S .360W) % !é^f9j L I =-1 ^ SPEAKER 8ÎKR.M. L R In order to show the connections, the left channel here is shown using the SPA-240 and the right channel the SPA-120. OUTPUT MIXER MODE MONO (BTL) ^ SPEAKER 8Q(R.M.S.360W) ,vf*v . • J fI : • L.................. J. i ^ h - " •V Q 1 (p) ’•) |ûj m 1 “ g ' 1 „ ) 360W) ' SPEAKER 8Q(R.M.S.1BOW) ' SPEAKER 8 Q ( R - M. S . 160W) . SPEAKER 8 Q (R. M. S.160W) Since the amplifier input impedances are in parallel, use mixer inputs with low impedances. 5 BLOCK DIAGRAM SPA-240 CH A INPUT (1^ 1 CH B INPUT BAL, I vx 2 ATT ;o—to) Rc 2 ? rfr Rc -V\AA- PRO- TECT I i I l^CH...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории