height. Note: the top case trim at the front is 1/2" higher and will overlap upper cabinetry or soffit. Use leveling legs and wheels for a maximum 1" height adjustment. Product Clearances These units are equipped with a 2-position door stop. The factory set 130. door swing can be adjusted to 90. if clearance to adjacent cabinets or walls is restricted. Order WX14X99 door stop for precise settings between 90.and 130.. 25" Minimum to Wall 130.Door Swing Corner Installation 90.Door Swing 23-7/8" Be
door swing and to allow pan removal. NOTE: A unified grille panel kit will NOT fit this installation. Listed by Underwriters Laboratories Specification Created 6/08 110151 ZIFP360NX GE Monogram® 36" Built-In Professional All-Freezer Features and Benefits • Stainless Exterior - Conveys a sense of solidity and beauty with tubular handles, louvered grille and chamfered, hand- finished edges • Enhanced Temperature Management System - With precise electronic controls and thermistors, maintains ideal
For even more capacity, install two refrigerators or two freezers. If you are installing two units, side by side, the installation space must be 71-1/2" wide. Additional cutout width may be required when side panels are used. Add side panel thickness to the finished cutout to calculate rough-in width. • The water and electrical locations for each product must be located as shown. • A separate 115V, 60Hz., 15 or 20 amp power supply is recommended for each product. 25" Min. to Wall 0" 25" Min. to
NOTE: A unified grille panel kit will NOT fit this installation. Listed by Underwriters Laboratories Specification Created 6/08 110153 ZIF360NX GE Monogram® 36" Built-In Custom All-Freezer Dimensions and Installation Information All-Refrigerator, 5/16" All-Freezer 1/4" Framed Trim Door/ Reveal Panel Drawer If you choose to install framed panels, they must be cut to the dimensions shown. The panels 1/4" will slide into the frame on the Panel door and grille. If the panel is less than 1/4" thick,
–At least 5" from either side of the opening. A 115 volt, 60 Hz. 15 or 20 amp power supply is recommended. An individual properly grounded branch circuit or circuit breaker is recommended, as noted on the rating plate. • Locate the electrical outlet within 5" x 7" shaded area shown. – 2-1/2" from the left side. Between 74" and 81" from the floor. Important: To insure a flush fit and access to the power cord, locate the electrical outlet as shown. 251Dia5925" Minimumto Wall130° Door Swing 36-3/4"