Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации DeWalt, модель N0003431

Производитель: DeWalt
Размер: 4.79 mb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


Leaks caused by loose fittings or worn or damaged hoses can result in injection injuries. DO NOT TREAT FLUID INJECTION AS A SIMPLE CUT! See a physician immediately! WARNING: Risk of fire, asphyxiation and burning. NEVER fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. • Never fill fuel tank completely. Fill tank to 1/2" (12.7 mm) below bottom of filler neck to provide space for fuel expansion.Wipe any fuel spillage from engine and equipment before starting engine. • Never run engine indoors or in enclosed, poorly ventilated areas. Engine exhaust contains carbon monoxide, an odorless and deadly gas. • DO NOT let hoses come in contact with very hot engine muffler during or immediately after use of your pressure washer. Damage to hoses from contact with hot engine surfaces will NOT be covered by warranty. CAUTION: NEVER pull water supply hose to move pressure washer. This could damage hose and/or pump inlet. • DO NOT use hot water, use cold water only. • Never turn water supply off while pressure washer engine is running or damage to pump will result. • DO NOT stop spraying water for more than two minutes at a time. Pump operates in bypass mode when spray gun trigger is not pressed. When the temperature inside the pump rises too high the thermal relief valve (T) will open and release a gush of water in an effort to lower the temperature inside the pump. The thermal relief valve will then close. If pump is left in bypass mode for more than two minutes internal components of the pump can be damaged. T start-uP ProCeDure 1. In a well-ventilated outdoor area, add fresh, high-quality, unleaded gasoline with a pump octane rating of 86 or higher. Do not overfill. Wipe up spilled fuel before starting the engine. Refer to engine instruction manual for correct procedure. 2. Check engine oil level. Refer to the engine instruction manual for correct procedure. 3. Connect the water hose to the water source. Turn the water source on to remove all air from the hose. When a steady stream of water is present, turn the water source off. 12 13 English 4. Verify the filter screen (U) is in water inlet of pump. U The cone side faces out. 5. Connect the cold water source (V) to pump inlet. NOTE : Water source must provide a minimum of 5 gallons per minute at 20 pSI (138 kPa). Warning: To reduce the possibility of contamination always protect against backflow when connected to a potable water system. 6. Connect high-pressure hose (P) to pump V outlet. P 7. If applying a chemical or cleaning solution, refer to Chemicals and Cleaning Solvents. 8. Turn the water source on. Caution : Risk of property damage. Failure to do so could cause damage to the pump. 9. Remove all air from the pump and high pressure hose by depressing trigger until a steady stream of water is present. 10. Turn the engine ON/OFF switch (H) to the ON position. 11. Place the fuel valve lever (M) in the ON postion. 12. If the engine is cold, move the choke (K) to the CLOSED position as shown. M H K 13. Warning: Risk of unsafe operation. Pull starter grip slowly until resistance is felt. Then pull starter grip (I) rapidly to avoid kickback and prevent hand or arm injury. Note: Do not allow the starter grip to snap back. Return it gently by hand. Warning: Risk of unsafe operation. If engine does not start after two pulls, squeeze trigger of gun to relieve pump pressure. Pull starter cord slowly until resistance is felt. Then pull cord rapidly to avoid kickback and prevent hand or arm injury. Note: If the oil level in the engine is low, the engine will not start. If the engine does not start, check the oil level and add oil as needed. 14. As the engine warms up, move the choke to the open position. 15. Depress trigger on gun to start water flow. Warning: Risk of unsafe operation. Stand on a stable surface and grip gun/wand firmly with both hands. Expect the gun to kickback when triggered. 16. Release trigger to stop water flow. DANGER: Risk of injury from spray. Engage the X trigger lock (X) when gun is not in use to prevent accidental spraying. 17. Adjust spray for the task being performed by changing quick connect nozzle. Refer to Spray Wand Nozzles. Shutting Down 1. If chemicals were applied, place the chemical hose into a container of clean water and draw clean water through chemical injection system to rinse system thoroughly. Caution : Risk of property damage Failure to do so could cause damage to the pump. 2. Place the engine ON/OFF switch (H) to the OFF Position. English English 3. Place the fuel valve lever (M) in the OFF postion. CAUTION: Risk of property damage. Never turn water supply off while pressure washer engine is running or damage to pump will result. 4. Turn water source off. 5. Pull trigger on spray gun to relieve any water pressure in hose or spray gun. 6. Refer to storage for proper storage procedures. MAInTEnAncE WARNING: Risk of burning. When performing maintenance, you may be exposed to hot surfaces, water press...

Эта инструкция также подходит к моделям:
Моечное оборудование - DPD3000IC (4.79 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории