Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Patton electronic, модель SMARTNODE 4110

Производитель: Patton electronic
Размер: 2.93 mb
Название файла: SN4520-4110.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Connect the SmartNode to the network............................................................................................................42 3. Load configuration............................................................................................................................................42 Bootloader.............................................................................................................................................................43 Start Bootloader ..............................................................................................................................................43 Start-up with factory configuration .................................................................................................................44 Load a new application image (SmartWare) via TFTP ....................................................................................44 Load a new application image (SmartWare) via the serial link .........................................................................46 Additional information..........................................................................................................................................46 Introduction This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration. Patton SmartNodes can be used for a wide variety of IP-based network applications. To support and ease the configuration of the SmartNodes configuration, templates for the most important applications are available on the Patton server at The main steps for setting up a new SmartNode (as of release 2.00 or 2.10) are shown in figure 24. Figure 24. Steps for setting up a new SmartNode 1. Configure IP address CAUTION The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. Power connection and default configuration First the SmartNode must be connected to the mains power supply with the power cable. Wait until the 'Run' LED stops blinking and lights constantly. Now the SmartNode is ready. The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 8. Table 8. Factory default IP address and network mask configuration IP Address Network Mask Interface Ethernet 0 (ETH0) DHCP DHCP Interface Ethernet 1 (ETH1) 192.168.1.1 255.255.255.0 Both Ethernet interfaces are activated upon power-up. If these addresses match with those of your network, go to section “2. Connect the SmartNode to the network” on page 42. Otherwise, refer to the following sections to change the addresses and network masks. Connect with the serial interface The Console port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see figure 25) between the SmartNode’s Console port and a PC or workstation’s RS-232 serial interface. Activate the terminal emulation program on the PC or workstation that supports the serial interface (e.g. HyperTerm). ConsoleVoIP Gateway RouterToIP Integrated Access DeviceSmartNode 4524Link100MActivity0/00/10/20/3Enet 0Voice PortsPowerRunVoIP LinkLink100MActivityEnet 1 Figure 25. Connecting to the terminal Terminal emulation program settings: •9600 bp •no parity •8 bit •1 stop bit •No flow control Login Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to display. Type the factory default login: administrator and leave the password empty. Press the Enter key after the password prompt. After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode. Changing the IP address Select the context IP mode to configure an IP interface. Now you can set your IP address and network mask for the interface eth0. Within this example a class C network (172.16.1.0/24) is assumed. The IP address in this example is set to 172.16.1.99 (you should set this to an unused IP address on your network). Copy this modified configuration to your new start-up configuration. Upon the next start-up the system will initialize itself using the modified configuration. The SmartNode can now be connected with your network. 2. Connect the SmartNode to the network CAUTION The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. Depending whether you connect the SmartNode to a host directly or via a hub or switch either straight- through wired or cross-over cables must be used (see figure 26). NoteThe SmartNode 4520 Series is equipped with Auto-MDX Ethernet ports. Use straight-through or cross-over cables for host or hub/switch connections. The SmartNo...

Эта инструкция также подходит к моделям:
Кромочные фрезеры - SMARTNODE 4520 (2.93 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории