|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
However, the fan speed is set to high. 1 Open the front cover. - Lift up both sides of the cover slightly. 2 Press the On/Off button. - For cooling and heating models, the operation mode changes, depending on the room temperature. - For cooling-only models, the temperature is set to 22°C (71.6°F). Restarting the air conditioner automatically When the air conditioner is turned on again after a power failure, this function restores the previous settings. This function is a factory default setting. 1 Open the front cover. - Lift up both sides of the cover slightly. 2 Press the On/Off button and hold it for 6 seconds. - The unit will beep twice and the lamp will blink 6 times. - To re-enable the function, press the On/ Off button and hold it for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times. 16 ADVANCED FUNCTIONS ENGLISH * The feature can be changed according to type of model. * The feature can be changed according to type of model. ON/OFF button Room temp. Set temp. Operation mode Below 21°C(69.8°F) 24°C(75.2°F) Heating operation Above 21°C(69.8°F) And Below 24°C(75.2°F) 23°C(73.4°F) Dehumidifying operation Above 24°C(75.2°F) 22°C(71.6°F) Cooling operation * The feature can be changed according to type of model. * The feature can be changed according to type of model. ON/OFF button ! NOTE If you press and hold the On/Off button for 3 – 5 seconds instead of 6 seconds, the unit will switch to the test operation. In the test operation, the unit blows out strong air for cooling for 18 minutes and then returns to the factory default settings. MAINTENANCE 17 MAINTENANCE Clean the product regularly to maintain optimal performance and to prevent possible breakdown. * This may not be provided, depending on the model. Item Cleaning interval Cleaning method Air filter 2 weeks See “Cleaning air filter.” Virus & Allergy Safe Filter +Triple Filter 3 months See “Cleaning anti-allergy filter and triple Filter.” Plasma (+HAF) filter* 3 months See “Cleaning the plasma (+HAF) filter.” Indoor unit surface Regularly Use a soft, dry cloth. Do not use bleach or abrasives. Outdoor unit Regularly Use steam to clean the heat exchanger coils and the panel vents (consult with technician). Plasma (+HAF) filter Virus & Allergy Safe Filter + Triple Filter Air filter CAUTION • Turn off the power and unplug the power cord before you perform any maintenance; otherwise it may cause electric shock. • Never use water that is hotter than 40°C(104°F) when you clean the filters. It may cause deformation or discoloration. • Never use volatile substances when you clean the filters. They may damage the surface of the product. ! ! NOTE • The location and shape of the filters may differ, depending on the model. • Make sure to clean the heat exchanger coils of the outdoor unit regularly, as dirt collected in the coils may decrease the operational efficiency or increase energy costs. * The feature can be changed according to type of model. ENGLISH 18 MAINTENANCE ENGLISH Cleaning the air filter Clean the air filter once every 2 weeks or more if necessary. 1 Turn off the power and unplug the power cord. 2 Open the front cover. - Lift up both sides of the cover slightly. * The feature can be changed according to type of model. 3 Hold the knob of the air filter, lift it up slightly and remove it from the unit. * The feature can be changed according to type of model. 4 Clean the filter with a vacuum cleaner or with warm water. - If dirt is difficult to remove, wash the filter in lukewarm water with detergent. 5 Dry the filter in the shade. Cleaning the anti-allergy filter and triple filter (Optional) 1 Turn off the power and unplug the power cord. 2 Open the front cover and remove the air filter (see “Cleaning air filter”). 3 Pull out the anti-allergy filter and the triple filter. 4 Dry the filter in direct sunlight for 2 hours. Cleaning the plasma (+HAF) filter (Optional) 1 Turn off the power and unplug the power cord. 2 Open the front cover and remove the air filter (see “Cleaning air filter”). 3 Remove the plasma (+HAF) filter in 10 seconds. 4 Use a vacuum cleaner to remove any dirt. - If dirt is difficult to remove, wash the filter with lukewarm water. 5 Dry the filter in the shade. * We suggest changing the HAF filter every 2years. Plasma filter HAF filter ! NOTE The location and shape of the filters may differ, depending on the model. ! NOTE • The location of the filters may differ, depending on the model. • The plasma filter may not be included in some models. • If you need more filters, please contact the LG service center. (Refer to the Warranty card.) * The feature can be changed according to type of model. * The feature can be changed according to type of model. ENGLISH MAINTENANCE 19 TROUBLESHOOTING Self-diagnosis function This product has a built-in self-diagnosis function. If an error occurs, the lamp of the indoor unit will blink in 2 second intervals. If this occurs, contact your local dealer or service center. Before ...
Эта инструкция также подходит к моделям:Кондиционеры - S24LHQ (1.48 mb)