.After 2 minutes of operation, shut the suction valve with the same wrench. .Turn the system off and switch mains supply off. .Disconnect tubing. After disconnection, protect valves and tubing ends from dust. .Compressor damage may occur if run at a negative suction pressure. Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 37 2011-3-19 10:08:21 38 Fixing the indoor unit in place Insulation Pipes 'X' mm Rubber leg 'Y' mm Perform the following work on the area where gas leak test was done priorly. After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation plate. 1. To avoid condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes. 2. Wind the pipe, assembly cable and drain hose with vinyl tape. 3. Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit. 4. Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place. Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor. If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground). 1. Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly. 2. Fix the outdoor unit in level to an appropriate support using anchor bolts. 3. If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly. 5. Wrap the rest of the pipe with vinyl tape. 6. Attach the pipe to the wall using clamps (optional). Installation plate Connecting wires Connecting Vinyl tape pipes Drain hose • Make sure pipe does not move when you install the indoor unit on an installation plate. Fixing the outdoor unit in place Model X Y ..09/12.. 457 254 ..18.. 543 319 ..24.. 660 340 • Ensure the wall will be able to suspend the weight of rack and outdoor unit; • Install the rack close to the column as much as possible; • Install proper grommet in order to reduce noise and residual vibration transferred by outdoor unit towards wall. Outdoor unit installed on the wall by rack Soft rubber designed to cut off vibration from rack to wall. (not supplied with product) Designed to cut off residual vibration from outdoor unit to rack. (not supplied with product) • Secure the rubber leg to prevent the generation of noise and vibration. Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 38 2011-3-19 10:08:22 ENGLISH 39 Final Check and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: •Strengthoftheinstallationsite•Tightnessofpipeconnectiontodetectgasleak•Electricwiringconnection•Heat-resistantinsulationofthepipe•Drainage•Groundingconductorconnection•Correctoperation(followthestepsbelow) 1. Press the Power button and check the following: .The indicator on the indoor unit lights up. .The airflow blade opens and the fan gears up for operation. 1. Turn on the air conditioner and select Cool mode to run the compressor for 3 minutes. 2 . Release the valve caps on High and Low pressure side. 3 . Use L wrench to close the valve on the high pressure side. 4 . Approximately 2 minutes after, close the valve on the low pressure side. 5 . Stop operation of the air conditioner. 6 . Disconnect the pipes. 3. Press the Air swing button and check the following: .The airflow blades work properly. 4. Press the Power button to stop the operation. 2. Press the Mode button to select Cool or Heat mode. .In Cool mode, use Temp + or -button and set the temperature at 16°C. .In Heat mode, use Temp + or -button and set the temperature at 30°C. Cooling mode (indoor unit check) .Inletairtemp.-Outletairtemp:From10°Kto12°K(indicativedeltaT) Heating mode (indoor unit check) .Outletairtemp.-Inletairtemp:From11°Kto14°K(indicativedeltaT) In heating mode, the indoor fan motor can remain off to avoid cold air blown into conditioned space. Pump down procedure (when removing the product) •Approximately3~5minuteslater,outdoorunitwillstarttooperateandtheCoolorWarmairwillblowout. •After12minutesofstationaryconditionchecktheindoorunitairtreatment: •Whenyoucompletetheinstallationsuccessfully,handoverthismanualtotheuserforstorageinahandyandsafeplace. Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 39 2011-3-19 10:08:23 ENGLISH 39 Final Check and Trial Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: •Strengthoftheinstallationsite•Tightnessofpipeconnectiontodetectgasleak•Electricwiringconnection•Heat-resistantinsulationofthepipe•Drainage•Groundingconductorconnection•Correctoperation(followthestepsbelow) 1. P...

Эта инструкция также подходит к моделям:
Кондиционеры - AQ09TSBN (5.17 mb)
Кондиционеры - AQ09TSBX (5.17 mb)
Кондиционеры - AQ09UGFN (5.17 mb)
Кондиционеры - AQ09UGFX (5.17 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории