Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Samsung, модель AQ12UGFN

Производитель: Samsung
Размер: 5.17 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If they are not supplied, you should obtain them before installing the air conditioner. Optional accessories Tools required for installation Insulated Assembly Pipe, O6.35mm (1) Insulated Assembly Pipe, O9.52mm (1) ..09.. Insulated Assembly Pipe, O12.70mm (1) ..12/18.. Insulated Assembly Pipe, O15.88mm (1) ..24.. PE T3 Foam Tube Insulation (1) Vinyl Tapes (2) Drain Plug (1) Rubber Legs (4) Pipe Clamps A (3) Pipe Clamps B (3) Cement Nails (6) M4 x 25 Tapped Screws (6) Drain Hose, length 2m (1) Putty 100g (1) • If these accessories are supplied, they will be in the accessory box. General Tools • Vacuum Pump(Backward flowing prevention) • Manifold Gauge • Stud Finder • Torque Wrench • Pipe Cutter • Reamer • Pipe Bender • Spirit Level • Screw Driver • Spanner • Drill • L Wrench • Measuring Tape Tools for test operations • Thermometer • Resistance Meter • Electroscope You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit. When facing the wall, the pipe and cable can be connected from the: • Right (A) • Left (B) • Underside_right (C) • Rear_right or left (D) A B D C D . Direction of pipe 1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65mm so that it slants slightly downwards. B A D C Pipe hole (O65mm) (Unit : mm) Model A B C D ..09/12.. 27 120 68 27 ..18/24.. 34 140 68 34 Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 27 2011-3-19 10:08:09 28 Wall <20mm Plastic Anchor Fixing the installation plate 2. Fix the indoor unit. If you fix the indoor unit on a wall (1) Fix the installation plate to the wall giving attention to the weight of the indoor unit. If you fix the indoor unit on a window frame (1) Determine the positions of the wooden uprights to be attached to the window frame. (2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit. (3) Attach the installation plate to the wooden upright using tapping screws. If you fix the indoor unit on a gypsum board (1) Use stud finder to find out locations of the studs. (2) Fix the plate hanger on two studs. •Ifyoumounttheplatetoaconcretewallusingplasticanchors,makesurethatgaps between the wall and the plate, created by projected anchor, is less than 20mm. •Searchforotherspotsiftherearelessthantwostuds,orthedistancebetweenthestudsaredifferentfromtheplate hanger. •Fixtheinstallationplatewithoutincliningtooneside. 1. Extend the assembly cable if necessary. •Donotconnecttwoormoredifferentcablestoextendthelength. It may cause fire. •Makesurethatawallcanwithstandtheweightoftheproduct.Ifyouinstalltheproductinaplacewhereitisnotstrong enough to withstand the product weight, the unit could fall and cause injury. Connecting the assembly cable .When you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15(..09/12..)/20(..18/24..) meters. •Connectthepowercabletotheauxiliarycircuitbreaker.Ifeverypolefailstoconnecttothe power supply, it must be incorporated in a wire with a contact opening of .3mm. Model Power cable Interconnection cable Type GL ..09/12..3G, 1.0mm. H07RN-F 5G, 1.0mm. H07RN-F 20A ..18..3G, 1.5mm. H07RN-F 2G, 0.75mm. H05RN-F 3G, 1.5mm. H07RN-F 25A ..24..3G, 2.5mm. H07RN-F 3G, 2.5mm. H07RN-F 2G, 0.75mm. H05RN-F Cable specification Connecting the cable Wall <20mm Plastic Anchor Fixing the installation plate 2. Fix the indoor unit. If you fix the indoor unit on a wall (1) Fix the installation plate to the wall giving attention to the weight of the indoor unit. If you fix the indoor unit on a window frame (1) Determine the positions of the wooden uprights to be attached to the window frame. (2) Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit. (3) Attach the installation plate to the wooden upright using tapping screws. If you fix the indoor unit on a gypsum board (1) Use stud finder to find out locations of the studs. (2) Fix the plate hanger on two studs. •Ifyoumounttheplatetoaconcretewallusingplasticanchors,makesurethatgaps between the wall and the plate, created by projected anchor, is less than 20mm. •Searchforotherspotsiftherearelessthantwostuds,orthedistancebetweenthestudsaredifferentfromtheplate hanger. •Fixtheinstallationplatewithoutincliningtooneside. 1. Extend the assembly cable if necessary. •Donotconnecttwoormoredifferentcablestoextendthelength. It may cause fire. •Makesurethatawallcanwithstandthew...

Эта инструкция также подходит к моделям:
Кондиционеры - AQ09TSBN (5.17 mb)
Кондиционеры - AQ09TSBX (5.17 mb)
Кондиционеры - AQ09UGFN (5.17 mb)
Кондиционеры - AQ09UGFX (5.17 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории