Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Carrier, модель AAW-08CM1FHU

Производитель: Carrier
Размер: 3.79 mb
Название файла:
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


3. For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a licensed electrician. Electric Shock Hazard ! If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps of all devices on that fuse or circuit breaker can not exceed the amps of the fuse of circuit breaker. If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker. To avoid the possibility of personal injury, disconnect the power to the unit before installing or servicing. 4. The wall outlet(3-pin) must match the plug (3-pin) on the power cord supplied with the unit. 5. The rating plate on the unit contains electrical DO NOT use plug adapters or extension cords. and other technical data. The rating plate is located See (Table 1) for receptacle and fuse information. on the right side of the unit. 125 5K 6K 8K 15 15 RATED VOLTS COOLING CAPACITY AMPS FUSE SIZE WALL OUTLET RECEPTACLE AND FUSE TYPES Time Delay Fuse (or circuit breaker) Plug type Table 1 Note: 5K including AAW-05CR1FHU AAW-05CM1FHU 6K including AAW-06CR1FHU AAW-06CM1FHU 8K including AAW-08CR1FHU AAW-08DR1FHU AAW-08CM1FHU AAW-08DM1FHU 6 WAC 5 6 8 USER MAN final 3/2/05 12:23 PM Page 9 TIPS BEFORE INSTALLATION Your Room Air Conditioner unit is designed to be highly efficient and save energy. Follow these recommendations for greater efficiency. 1. Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting. 2. The air filter is very efficient in removing airborne particles. Keep the air filter clean. Typically, filter should be cleaned once a month. More frequent cleaning may be necessary depending on outdoor and indoor air quality. 3. Use drapes, curtains, or shades to keep direct sunlight from heating your room, but DO NOT obstruct the air conditioner. Allow air to circulate around the unit without obstructions. 4. Start your air conditioner before outdoor air becomes hot and uncomfortable. This avoids an initial period of discomfort while the unit is cooling off the room. 5. When outdoor temperature is cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting. Your Room Air Conditioner was designed for easy installation in a single or double-hung window. NOTE: This unit is NOT designed for vertical (slider type) windows. CAUTION! ! To avoid installation/operating difficulties, read the instructions thoroughly. NOTE: Save the shipping carton and packing materials for future storage or transport of the unit. Please check the contents of the hardware kit agai...

Эта инструкция также подходит к моделям:
Кондиционеры - AAW-05CM1FHU (3.79 mb)
Кондиционеры - AAW-O6CM1FHU (3.79 mb)
Кондиционеры - AAW-05CM1FHU (3.79 mb)
Кондиционеры - AAW-06CR1FHU (3.79 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории