If the unit is tipped over, make sure it stands upright for at least 3 hours prior to turning it on. 8. Always place the unit on a level surface. 9. In order to cool, the hot air from the exhaust port in the rear of the portable air conditioner must be exhausted outside the room. 10. Make sure the portable air conditioner is connected to a grounded power outlet. 11. This portable air conditioner is designed to operate in an ambient temperature of 64°-100° F. 12. This portable air conditioner has been designed for residential use. 13. Always turn the portable air conditioner off before unplugging it. 14. Do not use this portable air conditioner for functions other than those described in this owner’s manual. 15. Do not tilt the portable air conditioner. 16. Do not cover or obstruct the intake or outlet grills. 17. Do not use the portable air conditioner in a wet room- such as a bathroom or laundry room- to avoid the possibility of shock. 18. Do not bend or crush the exhaust hose while in use. 19. Do not sit on, or place articles on, the portable air conditioner. 20. Do not touch the portable air conditioner with wet or damp hands. 21. Do not let chemical substances come into contact with the portable air conditioner. 22. Do not use the plug to start or stop the unit. 23. Always use the control panel to start or stop the portable air conditioner. 24. Always allow for air flow around the portable air conditioner of at least 20”. 25. Always turn off the portable air conditioner when not in use. 26. Always turn the portable air conditioner off and unplug it after use, before cleaning, before carrying out maintenance, and before moving it. 27. It the electrical socket is different from the plug, have a professionally qualified electrician replace the socket with a suitable one. Do not use adapter plugs, multiple sockets, or extension cords. 28. The filter must be used at all times. When removing the filter for cleaning, turn off the unit and unplug it. Parts and Accessories 1) Parts Ai r I nl et f or condenser si de Cont r ol Si gnal Recept or Cast er Oper at i on Panel Ai r I nl et Ai r Fi l t er Ai r Out l et Hot Ai r Di schar gi ng Por t Upper Dr ai n Por t Down Dr ai n Por t Use t o connect ai r hose. 2) Accessories Wat er Dr ai n Hose Wi ndow Ki t Mai n pi ece I ndoor Termi nal End Exhaust Duct Wi ndow Ki t Adapt er Installation When you use this portable air conditioner as an air conditioner or a dehumidifier, the hot air should be exhausted out of the room. When the unit is operating in fan-only mode, no exhaust is required. You do not need to hookup the window kit and hot air exhaust hose when you use the unit as a fan. If you use this portable air conditioner in cooling mode without venting the exhaust outside the room you are cooling, the net temperature in the room will rise, but the unit will still cool the area directly in from of its louvers. This portable air conditioner ships with the accessories for two primary types of installation: window installation (standard double-hung windows) and wall installation. 1) Exhaust Hose Installation The exhaust hose must be installed onto the unit before any further installation can occur. a) Pull out about 6” of one end of the exhaust hose. b) Screw the exhaust connector onto the exhaust hose in a clockwise motion. c) Snap the exhaust connector into place in the back of the unit. See below for a few notes about exhaust hose installation: Warning! The l engt h of t he exhaust hose suppl i ed wi t h t hi s uni t i s speci al l y desi gned f or i t . Do not ext end i t l est t he uni t mal f unct i on. Note: Mounting the exhaust hose The suppl i ed exhaust hose can be ext ended f r om 16 i nches t o 63 i nches l ong f or mount i ng. For best oper at i on, use t he shor t est , st r ai ght est possi bl e conf i gur at i on. Avoi d ki nks i n t he hose, whi ch may dr ast i cal l y r educe t he cool i ng power of t hi s uni t . 2) Window Installation a) Make sure the exhaust hose is properly installed onto the portable air conditioner as described above. b) Pull out about 6” of the free end of the exhaust hose and install the window kit adapter onto the exhaust hose by screwing it on in a clockwise manner. c) Open your window about 5”. d) Adjust the length of the window kit to the same width (or length) of the window. If necessary, the window kit can be cut to size. e) Place the window kit in your window, with the exhaust hole as near as possible to the portable air conditioner. f) Close the window on the window kit. For long-term installation or to make the window kit more stable, you may want to screw the window kit into your window frame. g) Adjust the length of the exhaust hose and mount the window kit adapter to the window kit. Notes: These installation instructions can also be followed for sliding door installation (a longer window kit will be required). Installation as detailed above will not allow the window to be properly closed or locked while the window k...
Эта инструкция также подходит к моделям:Кондиционеры - PAC9000 (1.19 mb)
Кондиционеры - PAC9000 (1.19 mb)
Кондиционеры - PAC9000 (1.19 mb)
Кондиционеры - PAC9000 (1.19 mb)