|
Фрагмент инструкции
Plugging and unplugging cables while servers are powered on may cause irreversible damage of the servers and/or the LCD Rack Console. Belkin is not responsible for damage caused in this way. You are now ready to begin installation of your LCD Rack Console. The following sections (pages 11–13) provide complete instructions for the hardware setup of a single LCD Rack Console (F1DC108C-US, F1DC116C-US). 1 2 3 4 5 6 7 8 section 11 Installation Connecting Servers to the LCD Rack Console (PS/2 Connection): Step 1 Make sure your server is powered off. Step 2 Using the Belkin Dual-Port Micro-Cable Kit for PS/2 (F1D9400-XX), connect the VGA connector to the monitor port on your server. (Refer to diagram below.) Step 3 Connect the PS/2 mouse and keyboard connectors to the mouse and keyboard ports on the server. (Refer to diagram below.) 6 Installation Step 4 Connect the Belkin Dual-Port Micro-Cable Kit for PS/2 to the desired host ports on the PRO3 KVM Switch. (Refer to diagram below.) 6 Step 5 Power up your server. Step 6 Repeat Steps 1 through 5 for each additional PS/2 server you wish to connect. Connecting Servers to the LCD Rack Console (USB Connection): Step 1 Make sure your server is powered off. Step 2 Using the Belkin Dual-Port Micro-Cable Kit for USB (F1D9401-XX), connect the VGA connector to the monitor port on your server. (Refer to diagram on next page.) Step 3 Connect the USB connector to an available USB port on the server. (Refer to diagram on next page.) 1 2 3 4 5 6 7 8 section 13 Installation 6A Step 4 Connect the Belkin Dual-Port Micro-Cable Kit for USB to the desired host ports on the PRO3 KVM Switch. (Refer to diagram below.) Your server should recognize the KVM-Switch connection and automatically install the HID USB driver, if necessary. Step 5 Repeat Steps 1 through 4 for each additional USB server you wish to connect. Note: We recommend that you attach the Belkin Dual-Port Micro-Cable USB Kit directly to a free USB port on your server. Note: When a USB Cable Kit is connected to a Sun server, the Server Interface Module emulates the Sun keys using a set of key combinations called “combo keys”. Refer to the table on page 28 for a list of Sun functions supported by the LCD Rack Console. 14 Installation Connecting the LCD Rack Console with Multiple PRO3 KVM Switches (Daisy-Chaining) You can daisy-chain up to 15 additional PRO3 KVM Switches (F1DA104Z, F1DA108Z, F1DA116Z, F1DA104Q, F1DA108Q, and F1DA116Q), allowing a server administrator to manage up to a maximum of 256 servers from one console. Each daisy-chained PRO3 KVM Switch is referred to as a “BANK” and is assigned an address. The LCD Rack Console is BANK 00 and is referred to as the “primary” KVM switch. BANKs 01 through 15 are referred to as “secondary” KVM switches. Note: The LCD Rack Console (F1DC108C-US, F1DC116C-US) must be designated as the primary KVM switch. Refer to the diagram below. cable 1 cable 2 cable 3 Primary unit (BANK 00) Secondary unit (BANK 01) Secondary unit (BANK 02) Secondary unit (BANK 03) Note: A Daisy-Chain Cable (F1D108-CBL) is required to daisy-chain each PRO3 KVM Switch and is available through your Belkin reseller, or online at Installation How to Assign a BANK Address All PRO3 KVM Switches feature a “BANK DIP” switch. The “BANK DIP” switch is used to assign the proper BANK address to each PRO3 KVM Switch. • For a multi-unit configuration, the primary KVM switch (LCD Rack Console) is always set to “BANK address 00”. Each secondary unit must be set to a unique BANK address (from 01 through 15). Refer to the chart below for “BANK DIP” switch settings. BANK-DIP-Switch Configuration Chart 3 1 2 4 5 6 7 8 section DIP SWITCH# BANK ADDRESS 1 2 3 4 5 6 ON ON ON ON ON ON BANK 0 (default) PRIMARY (default) ON ON OFF ON ON ON BANK 1 SECONDARY ON ON ON OFF ON ON BANK 2 SECONDARY ON ON OFF OFF ON ON BANK 3 SECONDARY ON ON ON ON OFF ON BANK 4 SECONDARY ON ON OFF ON OFF ON BANK 5 SECONDARY ON ON ON OFF OFF ON BANK 6 SECONDARY ON ON OFF OFF OFF ON BANK 7 SECONDARY ON ON ON ON ON OFF BANK 8 SECONDARY ON ON OFF ON ON OFF BANK 9 SECONDARY ON ON ON OFF ON OFF BANK 10 SECONDARY ON ON OFF OFF ON OFF BANK 11 SECONDARY ON ON ON ON OFF OFF BANK 12 SECONDARY ON ON OFF ON OFF OFF BANK 13 SECONDARY ON ON ON OFF OFF OFF BANK 14 SECONDARY ON ON OFF OFF OFF OFF BANK 15 SECONDARY ON = Up Position, OFF = Down Position Example: Three 8-Port PRO3 KVM Switches (F1DA108Z) are daisy-chained together with an LCD Rack Console to manage up to 32 servers. The DIP switch on the primary KVM (LCD Rack Console) switch is set to “BANK 00” (factory default) and the secondary units are each set to a unique BANK (between 01 and 03). 15 16 Installation Example of Daisy-Chain Configuration Getting Started: Step 1: Make sure that all servers, LCD Rack Console, and PRO3 KVM Switches are powered off and that each PRO3 KVM Switch has been assigned a unique BANK address. Step 2: Place all primary and secondary KVM switches in the desired location. cabl...
Эта инструкция также подходит к моделям:Компьютерные аксессуары - F1DC116C-US (1.57 mb)
Компьютерные аксессуары - F1DC1XXC-US (1.57 mb)