Войти:
Оценок - 0, средний балл: 4 ( )

Инструкция по эксплуатации Desa, модель (V)TC36P

Производитель: Desa
Размер: 2.04 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


These models are tested and approved for use with DESA (directvent) pipe components and terminations. The venting system must terminate on the outside of the structure andcan not be attached to a chimney or flue system serving a separatesolidfuelorgasburningappliance.Adirect-ventappliancemusthaveits own venting system. DO NOT common vent this appliance. These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines: • When venting system terminates horizontally on an outside wall, you may install a standoff if the termination cap is to be installed directly on a combustible finish such as vinyl, wood, stucco, etc. • Never run the vent downward as this may cause excessive temperatures which could cause a fire. • Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which requires 2" clearance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required. • Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 11). • Have fireplace and selected vent components on hand to help determine the exact measurements when elbowing or offsetting. Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces. • Install horizontal venting with a 1/4" rise for every 12" of run toward the termination. WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. INSTALLATION PRECAUTIONS • Wear gloves and safety glasses for protection • Use extreme caution when using ladders or when on roof tops • Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system: • Installation of any damaged venting component • Unauthorized modification of the venting system (Do not cut or alter vent components) • Installation of any component part not manufactured orapproved by DESA • Installation other than as instructed by these instructions WARNING: This gas fireplace and vent assembly must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each direct-vent gas appliance must use a separate vent system. Do not use common vent systems. WARNING: Vent pipe air space clearances to combustibles are 1" on all sides except on the horizontal sections, which require 2" clearances from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required. NOTICE: Failure to follow these instructions will void the warranty. NOTICE: Do not seal termination cap to vent pipe. Cap must be removable for vent inspection and maintenance. 116192-01C 8 VENTING INSTALLATION INSTRUCTIONS Installation Planning VENTING INSTALLATION INSTRUCTIONS Continued INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination Horizontal Termination Installation IMPORTANT: Horizontal square terminations require only inner portion of wall firestop. Horizontal installations using round termination require exterior portion of wall firestop (see Figure 14, page 10). 1. Set the fireplace in its desired location and determine the routeyour horizontal venting will take. Do not secure the fireplaceuntil all venting has been installed. Some installations requiresliding the fireplace in and out of position to make final ventingconnections. Figures 14 through 18 on pages 10 through 12 showdifferent configurations for venting with horizontal terminationthat will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path ofyour desired venting route. If they are, you may want to adjustthe location of the fireplace. 2. Direct vent pipe sections and components are designed with special twist-lock connections. Twist-Lock Procedure: The female ends of the pipes have locking lugs (indentations). These lugs will slide straight into matching slots on the male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approximately one-quarter turn until the sections are fully locked (see Figure 8). Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose. 3. Use a 45° elbow to connect venting system to fireplace flue collar. The elbow is designed to be twist-locked onto the flue collar as described in step 2. IMPORTANT: Do not attempt to alter the configuration of the elbow by cutting, twisting, bending, etc. 4. Assemble the desired combination of pipe and elbows to the fireplace flue collar. If there are long portions of venting run, pre-assembled pipe sections may be installed as subassemblies ...

Эта инструкция также подходит к моделям:
Камины - (V)TC36N (2.04 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории