Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Desa, модель (V)TC36N

Производитель: Desa
Размер: 2.04 mb
Название файла: a46c22c1-cb99-b0c4-fd5a-23cfcf223c37.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Speed Control Switch Bracket Duplex Outlet (Located Control underneath firebox Knob floor against lower right outside wall) Control Shaft Locknut Blower Plug-In Figure 26 - Attaching Speed Control to Firebox Va riable Fan S witc h W h it e W h ite B la ck GreenOn 11 0 / 1 1 5 V.A . C. B low e rM otor B l a ck BlackBlack Off Wiring Diagram Decal 12" in Front of Blower 4. Be certain that all wire terminals are securely attached to terminals on blower motor and thermal switch and that the screw for the thermodisc bracket and green ground wire is tight. Power Cord Magnetic Thermal Strips Switch Bracket Black Wire Phillips Screw Blue Wire Ring Terminal on Green Wire White Wire Thermal Switch Air Flow Direction Air Flow Direction Thermodisc Route BKT Blower Through This Area Magnets Blower Side View Firebox Bottom Location Figure 28 - Blower Model BKT Figure 27 - Location of Wiring Diagram Decal (Model May Vary From Illustration) 116192-01C 18 FIREPLACE INSTALLATION Installing Optional Blower Accessories (Cont.) Installing Gas Piping to Fireplace Location FIREPLACE INSTALLATION Continued 5. Mount the speed control box against the mounting plate providedin the lower fireplace cavity by placing the plastic control shaftforward through the round hole (see Figure 26, page 17). 6. While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against mounting plate. Place control knob provided on shaft (see Figure 26, page 17). 7. Check to make sure that the power cord is completely clear of theblower wheel and that there are no other foreign objects in blowerwheel. Also double check allwire leads and makesurewire routingis not pinched or in a precarious position. Correct accordingly. 8. Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16. 9. Plug in blower power cord to duplex outlet. 10. The blower will only run when the speed control knob is in theON position and the thermal switch senses temperature after thefireplace begins to heat up. The blower speed can be adjusted byrotating the controlknob. To turn off,turn knobfully counterclockwise until it clicks off. If the blower is ON and has been runningwith the fireplace operating, the blower will continue to run for ashort time after the fireplace has been turned off. As the thermalswitch cools down, the blower shuts down automatically. 11. Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27, page 17). Blower Wiring Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Variable Fan Switch Fan Switch Blue (N.O.) Green White On 110/115 V.A.C. Blower Motor Black Off 1 2 Black INSTALLING GAS PIPING TO FIREPLACE LOCATION WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the fireplace and propane/LP supply. Installation Items Needed Before installing fireplace, make sure you have the items listedbelow. • external regulator (supplied by installer) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge connection * • sediment trap • tee joint • pipe wrench • approved flexible gas line with gas connector (if allowed by local codes) *A CSA design-certified equipment shutoff valve with 1/8" NPT tapis an acceptable alternative to test gauge connection. Purchase theCSA design-certified equipment shutoff valve from your retailer. For propane/LP connection only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 30. Pointing the vent down protects it from freezing rain or sleet. External Propane/LP Regulator Supply Tank Vent Pointing Down Figure 30 - External Regulator with Vent Pointing Down Figure 29 - Blower Wiring Diagram for Thermostat-Controlled (Propane/LP Only) Models 116192-01C FIREPLACE INSTALLATION Installing Gas Piping to Fireplace Location (Cont.) Connecting Fireplace to Gas Supply Checking Gas Connections 19 FIREPLACE INSTALLATION Continued CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas.Checkyourlocalcodes.Usepipeof1/2"diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur. Installation must include an equipme...

Эта инструкция также подходит к моделям:
Камины - (V)TC36P (2.04 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории