Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Desa, модель (V)CB36P(E)

Производитель: Desa
Размер: 2.37 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2. Press the ON/OFF button to turn the burner on and off. Ignitor Pilot Burner Sensor Rod Figure 35 - Pilot optional Hand-Held REMOTE OPERATION Note: All remote control accessories must be purchased separately (see Accessories, page 34). Follow instructions included with the remote control. NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instructions, page 20. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 36). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery. On/Off Series Model HRC100 Hold the control button on the hand-held remote until burner turns on. Hold the control button again until burner turns off (see Figure 37). To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. To Unlock press both buttons together on hand-held remote control until the light stops flashing. The hand-held remote is now unlocked. OPTIONAL GWMS2 ON/OFF WALL MOUNTED SWITCH WARNING: Do not connect the appliance gas controls to a 120 VAC power source. Damage or injury may occur. Light the fireplace as instructed in Lighting Instructions on page 20 . If using an HRC remote with a wall switch, set the remote selector switch to the ON position (see Figure 36). The wall switch may now be used to turn the burner flame ON and OFF. To turn the fireplace off, turn the wall switch and/or remote selector switch to the OFF position and turn the gas control knob back to PILOT. The pilot will remain lit. IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position. Operating Fireplace Continued Indicator Light Control Button Figure 37 - On/Off Hand-Held Remote Control Unit HRC100 Blower Control Knob (Optional Accessory) Variable Control Knob OFF PILOT LO IH ONOFFREMOTEONOFFON Gas Control Knob in ON Position Selector Switch in Remote Position Figure 36 - Setting the Selector Switch, Gas Control Knob and Variable Control Knob for Remote Operation Inspecting Burners Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary. The position and pattern of the pilot flames in relation to the sensing devices should be as shown in Figures 38 and 39 respectively. The pilot flame may need adjustment in order for the thermocouple, thermopile and/or ignition system to sense the pilot flame. If your pilot assembly does not meet these requirements: • turn fireplace off (see To Turn Off Gas to Appliance, page 19 or 20) • see sections under Troubleshooting, page 25 Burner Flame Patterns Burner flames will be steady, not lifting or floating. Flame patterns will differ from unit to unit and will vary depending on installation type and weather conditions. If vent configuration is installed incorrectly, flames will lift or “ghost”. This can be dangerous. Inspect flames after installation to ensure proper installation and performance. Figure 40 shows a typical flame pattern. If burner flame pattern differs from that described: • turn fireplace off (see To Turn Off Gas to Appliance, page 19 or 20) • see Troubleshooting, page 25 Air Adjustment Setting The main burner air shutter opening is factory set to the following: Natural Gas - 1/8", Propane/LP Gas - 3/4" The air shutter may require adjustment depending on altitude, venting condition, burner operation and general flame appearance. If flames are lifting or sooting the shutter may require opening. If flames are too blue or improperly lighting the shutter may require closing. See Figure 41 for proper air adjustment. IMPORTANT: Do not reduce air shutter opening any lower than designed minimum stop setting of 1/8". Thermopile 3/8" to 1/2" Pilot Burner 1/4" Figure 40 - Typical Flame Pattern Thermocouple Piezo Ignitor Figure 38 - Pilot Assembly (Millivolt Ignition System) Sensor Rod Pilot Burner Piezo Ignitor Burner Tube Air Shutter Figure 39 - Pilot Assembly Electronic Ignition System) Adjustment Screw 1/8" Minimum Air Opening Figure 41 - Adjusting Air Setting Cleaning and Maintenance WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passages of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualif...

Эта инструкция также подходит к моделям:
Камины - (V)CB36N(E) (2.37 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории