Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Dimplex, модель EWM-SS-BLK

Производитель: Dimplex
Размер: 516.5 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WARNING The wall mounted electric fireplace requires the wall mounting bracket screws to be installed into a minimum of one wall stud. (FIGURE 3 & 4) 1. Select the desired location near an electrical outlet. 2. Ensure the front of the unit when installed is at least 3 feet (0.9m) from combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains. 3. Mount the unit on the wall only with the bottom above an electrical outlet or a minimum of 12” (mounting bracket 34 3/4”) above the floor. Access to the electrical outlet must be maintained. Ensure the installation meets the national and state/provincial electrical codes. NOTE: It is recommended that the bottom of the unit not be mounted higher than 30” from the ground (mounting bracket no higher than 52 3/4”). 4. To mount the unit so that the wall outlet is hidden, mount the bracket 19” above the top of the outlet (FIGURE A). 2 5. The wall-mounting bracket must be mounted to at least one wall stud (FIGURE 3) or into two wall studs (FIGURE 4) 6. When installing into two studs the wall anchor must be installed into the center location as indicated in FIGURE 3. 7. When installing into one stud, use one of the three center locations as indicated in FIGURE 4. The wall anchors must be installed into the outer most locations as indicated in FIGURE 4. 8. Hold the wall-mounting bracket on the wall and mark the location of ONE of the mounting holes. 9. Install the bubble level onto the top of the wall-mounting bracket. (FIGURE 3 & 4). 10. Adjust the wall-mounting bracket so the bubble on the level is centered between the two black lines. 11. Mark 4 other mounting screw locations on the wall bracket ensuring that the wall bracket stays level. 12. Drill 1/4” holes into the wall on the marked locations where the wall anchors are to be installed. (FIGURE 1) 13. Insert the wall anchors into the 1/4” holes in the wall. 14. Insert the wall anchor screws through the wall bracket and thread into the wall anchors. Tighten the screw. (FIGURE 2) 15. Install the remaining screws into the wall studs as required. Note: At least one of the mounting screws must be installed into a wall stud. 3 .” Hole FIGURE 2 Wall Anchor Wall Bracket Screw .” Hole in wall insert plastic FIGURE 1 anchor 4 FIGURE 3 FIGURE 4 UNIT INSTALLATION CORD SECURING (VIEW FROM BACK) 5 OPERATION The controls are located on the lower right side of the wall mounted electric fireplace. (FIGURE 7) A. MAIN ON/OFF SWITCH The switch has two ON positions marked with and “Manual”. The “Manual“ position is for manual operation. In this position the built-in remote control is by passed. The position is for operating the unit with the provided remote control. When in position the unit is operated with the ON and OFF buttons of the remote control. When the switch is in the center position the unit is off. B. HEATER ON SWITCH The HEAT ON/OFF SWITCH supplies power to the heater fan and the heater element. When the switch is in the ON position the heater operates if the thermostate calls for heat. C. HEATER THERMOSTAT CONTROL To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. NOTE: When the heater is switched ON, the heater fan will operate. The heater element may or may not be on, depending on the thermostat control setting (SEE “HEATER THERMOSTAT CONTROL”). A B C FIGURE 7 (LOWER RIGHT SIDE) RESETTING THE TEMPERATURE CUTOFF SWITCH Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the MAIN ON/OFF SWITCH to OFF and waiting 5 minutes before switching the unit back on. CAUTION If you need to continuously reset the heater, unplug the unit and call Dimplex customer service at 1-888-DIMPLEX (1-888-346-7539). REMOTE OPERATION The Fireplace is supplied with an integrated on/off remote control Note: Ensure that the fireplace 3 position switch is set to the remote Control setting. (Up position) To operate, push the ON button to turn fireplace on, push the OFF button to turn the fireplace off. BATTERY REPLACEMENT To repalce the battery, slide battery cover open on the hand held transmitter. Correctly install one 12 volt (A23) battery in the battery holder. Close the battery cover. 7 ON BUTTON OFF BUTTON BATTERY BATTERY COVER MAINTENANCE WARNING Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. LIGHT BULB REPLACEMENT Allow at least 5 minutes for light bulbs to cool before touching bulbs to avoid accidental burning of skin. Light bulbs need to be replaced when you notice a dark secti...

Эта инструкция также подходит к моделям:
Камины - EWM-COPPER (516.5 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории