Two 45o elbows equal one 90o elbow. RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft. See Table 1. 1) At sea level minimum height is 12' straight. 2) Add the following vertical height to compen sate for: 45 deg. elbow = 1 ft. 90 deg. elbow = 2 ft. "T" = 3 ft. Each foot of horizontal run = 2 ft. 3) Add 4% overall for each 1000' above sea level. Example: a) 1-1/2 ft. of horizontal run = 3 ft. one "T" = 3 ft. Total Addition (at sea level) = 6 ft. Example: b) One 90 deg. elbow = 2 ft. 2 ft. of horizontal run = 4 ft. one "T" = 3 ft. Total Addition (at sea level) = 9 ft. Recommended Flue Height Elevation Example a) Example b) 0' 18' 21' 1000' 18.72' 21.84' 2000' 19.44' 22.68' 5000' 21.60' 25.20' 8000' 23.76' 27.72' MOBILE HOME INSTALLATION Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items #1 through #8, a supply of fresh air has to be supplied to your unit. Cut a minimum 4 inch diameter hole through your floor protector and the floor directly under your pedestal base to the outside. Use 4" duct pipe with a mesh grill to pipe fresh air into the pedestal area. Block off the hole in the back of the pedestal with the square plate and the two 1/2" screws provided. Place your unit in position and secure it to the floor using two lag bolts 3/8" x 3-1/2" through the two holes inside the pedestal base. It is important to maintain the structural integrity of the Mobile Home floor, walls and roof when installing your unit. For Mobile Home units installed in the U.S. the unit must be grounded using a #8 ground wire with approved termination and star washer. WARNING: Minimum height requirements must be met. Safe removal of the chimney system must be adhered to when transporting the mobile home. WARNING: Operate only with door fully closed - open feed door to feed fi re only. Regency Freestanding Woodstove INSTALLATION LISTED COMPONENTS FOR MOBILE HOME INSTALLATION The Regency Small and Large Freestanding pedestal units are approved for installation in a Mobile Home if one of the following pipe systems is used. U.S. Installation* METALBESTOS SSII Qty. Part # Description 1 6DS-VK Connector Kit 1 6TMH Shield/Support 1 6TAF-6 Flashing 1 6T-36 Chimney Length 1 6T-18 Chimney Length 1 6T-CT Rain Cap PRO-JET 3103 Qty.Part # Description 1 PV06-TK Connector 1 CSB Shield/Support 1 RRS Radiation Shield 1 LFR03 Flashing 1 SL3 Chimney Length 1 SL1 Chimney Length 1 RCSA Rain Cap SECURITY ASHT Qty.Part # Description 1 DL42A-6 Connector Kit 1 6SS Shield/Support 1 6FAMH Flashing 1 6L3 Chimney Length 1 6L1 Chimney Length 1 CPE Rain Cap SECURITY S2100 Qty.Part # Description 1 DL42A-6 Connector Kit 1 6XSF Support 1 6XFA Flashing 1 6XL3 Chimney Length 1 6XL18 Chimney Length 1 6XCPE Rain Cap METAL-FAB TEMP/GUARD 2100 Qty.Part # Description 1 6DWBK Connector 1 6TGRS Roof Support 1 6TGG36 Chimney Length 1 6TGG12 Chimney Length 1 6TGF Flashing 1 6TGC Rain Cap AMERI-TEC HS Qty.Part # Description 1 6DCC Connector 1 6HSRS-12 Roof Support (6PLRS-12-BK) 1 6F Flashing 1 6HS-36 Chimney Length 1 6HS-18 Chimney Length 1 6HS-RCS Rain Cap (6PL-MPC) SIMPSON DURA-PLUS Qty.Part # Description 1 6DVL8693 Connector Kit 1 6DP-MH9096 Mobile Home Kit ICC EXCEL 2100 Qty.Part # Description 1 6CL48 48" Chimney length (also in 12",18", 24" lengths. 1 6RC Rain Cap 1 6RCS Spark Screen (for rain cap) 1 6RDS/SQS Round/Square support box 1 6VF Flashing 1 6UBA "Ultrablack" Close Clearance Connector Canadian Installations* SECURITY S2100 (see above for details) ICC EXCEL 2100 (see above for details) *The use of alternate pitch flashings, support box extensions, additional chimney lengths, and additional chimney bracing, may be used on each of the previously listed systems. These parts though must be from the same system as listed, and must be a similar and/or complimentary part. CAUTION: At no time use unlabelled parts, or substitute parts made for another chimney system. Install as per chimney manufacturer's installation instructions. Regency Freestanding Woodstove INSTALLATION BRICK FLUE BAFFLE & SECONDARY AIR TUBE INSTALLATION The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The brick baffl es must be installed prior to your first fire. Smoke spillage and draft problems may occur if the baffles are improperly positioned. Check the position of the brick baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox. The Large Stoves F3100L and S3100L are shipped with one of the secondary air tubes loose inside the firebox. It needs to be installed after the brick baffle are installed. Follow the directions below. Large Stove F3100L The unit arrives with the third air tube (from the front) and the 2 baffle bricks on the floor of the firebox. The baffle bricks are positioned first and then the air tubes are installed. 1) Slide the left baffle brick over the two rear air tubes and then p...
Эта инструкция также подходит к моделям:Камины - F1100S (1.27 mb)