Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации Regency, модель 946-523/P

Производитель: Regency
Размер: 909.23 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram, see manual. FPI Direct Vent (Flex) System Termination Kits include all the parts needed to install the P33 using a fl exible vent. ImportantWhen installing Cabinet Mantels: the wall thimble must be secured first and venting must be attached to unit before sliding into final position. Snorkel Terminations Snorkel Terminations: FPI Kit # Length Contains: #946-513 2 Feet 1) 6-5/8” flexible liner (Kit length) 2) 4” flexible liner (Kit length) 3) spring spacers (3) 4) thimble (2) 5) AstroCap termination cap (1) 6) screws (12) 7) tube of Mill Pac (1) 8) plated screws (8) 9) S.S. screws #8 x 1-1/2” drill point, (4) #946-515 4 Feet #946-516 10 Feet For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are available. Follow the same installation procedures as used for standard Horizontal Termination. NEVER install the snorkel upside down. Riser Vent Termination Notes: 1) Liner sections should be continuous without any joints or seams. Min. 12"* 2) Only Flex pipe purchased from Regency may be used for Flex (305mm) installations. 3) Horizontal sections must be supported every 3 feet. Min. 6-1/4"* (159mm) Dura-Vent Snorkel 6-7/8" (173mm) dia. Flue pipe 4" (102mm) dia. flue pipe Wall Thimble (2 pc) Termination Cap (Part# 946-523/P) AstroCapTM spring spacer Alternate Horizontal Termination Caps Below Grade Snorkel Installation (Dura-Vent Only) If the Snorkel Termination must be installed below grade, i.e. basement application, proper drainage must be provided to prevent water from entering the Snorkel Termination. Refer to Rigid Pipe Installation instructions for details. Do not attempt to enclose the Snorkel within the wall, or any other type of enclosure. Min. 12"*(305mm) Adequatedrainage Window Well Dura-Vent Snorkel If required by the external termination location the listed alternate termination caps may be used. Gravel 32 August 2008 Product Specifi cations Book Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Rigid Pipe Venting Horizontal or Vertical Terminations 2 4 6 8 1012 121214 Venting Arrangements - Vertical Terminations Rigid Pipe System (Propane & Natural Gas) The P33 is approved for a maximum 40 ft. straight vertical, with Rigid Pipe vent systems for Propane and Natural Gas. The lightly shaded area, , in the diagram shows allowable venting configurations with a maximum two 45° elbows. The darker shaded area, , in the diagram shows allowable venting configurations using one 45° and one 90° elbow. • Vent must be supported at offsets. • Horizontal sections must be supported every 3 feet. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustible materials. • Minimum of 1’ pipe section between elbows. Note: Must use optional rigid pipe adapter when using Rigid Pipe (Part # 510-994). * Unit must be raised by 1” when using Contemporary Faceplate Vertical Height (Feet) If required by the external termination location the listed alternate termination caps may be used. (Refer to Page 11) Alternate Horizontal Termination Caps August 2008 Product Specifications Book Maximum: 40 ft. (12.2m) Minimum 9’6” (2.9m) Minimum 8’6” (2.6m) Max. 10’ (3m)(centerline to centerline)Minimum 12” (305mm) Maximum: 27 ft. (8.2m) 0 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 33 Gas Fireplaces Gas Fireplaces Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Vertical Venting with Two (2) 90° Elbows Vertical Venting with Three (3) 90° - Initial vertical section. Elbows - Initial vertical section. Two 45° elbows = One 90° elbow Two 45° elbows = One 90° elbow Option V H V+ V1 Maximum total pipe: length, of all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet. Minimum of 1 foot between 90° elbows is required. A) 1’ Min. 4’ Max. 2’ Min. B) 2’ Min. 5’ Max. 3’ Min. C) 3’ Min. 6’ Max. 4’ Min. D) 4’ Min. 7’ Max. 5’ Min. E) 5’ Min. 8’ Max. 6’ Min. Option V H + H1 V+ V1 Maximum total pipe: length, of all sections, must not exceed 30 feet. Total horizontal sections must not exceed 8 feet. Minimum of 1 foot between 90° elbows is required. A) 2’ Min. 3’ Max. 4’ Min. B) 3’ Min. 4’ Max. 6’ Min. C) 4’ Min. 5’ Max. 7’ Min. D) 5’ Min. 6’ Max. 8’ Min. E) 6’ Min. 7’ Max. 9’ Min. F) 7’ Min. 8’ Max. 10’ Min. Vertical Venting with Two (2) 90° Elbows - Initial horizontal section. Two 45° elbows = One 90° elbow Vertical Venting with Three (3) 90° Elbows - Initial horizontal section. Two 45° elbows = One 90° elbow Option H + H1 V Maximum total pipe: length, of all sections, must not exceed 30 feet. Total horizontal sections must not exceed 6 feet. Minimum of 1 foot between 90° elbows is required. A) 2’ Max. 2’ Min. B) 3’ Max. 3’ Min. C) 4’ Max. 4’ Min. D) 5’ Max. 5’ Min. E) 6’ Max. 6’ Min. Option H V H + H1 V+ V1 Maximum total pipe: length, of all sections, must not ...

Эта инструкция также подходит к моделям:
Камины - 510-994 (909.23 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории