Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Majestic Appliances, модель ODGSR42A

Производитель: Majestic Appliances
Размер: 1.09 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Remove the front panel just below the front of the hearth pan. This is accomplished by lifting on the panel. To replace the valve access panel line up the two pins with the holes in the surround bottom and push the panel over the front of the hearth pan. (Fig. 5) 2. Lift the brick with the Majestic logo on it. (Fig. 6) ODGSR Series Outdoor Gas Fireplace Remote Wall Switch Gas Line Installation This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure equal to or less than 1/2 psig (3.45 kPa). The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa). If gas piping from the source to the appliance location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. The gas pipeline can be brought in through the right side of the appliance. A knockout is provided to allow for the gas pipe installation and testing of any gas connection. NOTE: The gas line connection can be made with 3/8" copper tubing approved for propane or natural gas, 1/2" rigid pipe or an approved flex connector, then reduced to 3/8" to the appliance. Because some municipalities have some additional local codes, it is always best to consult your local authority. U.S.: Consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Canada: CSA - B149.1 installation code. Test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open flame. The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control. When using copper or flex connector use only approved fittings. Always provide a union so that gas line can be easily disconnected for burner or fan servicing. See gas specification for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the appliance. (Fig. 10) 1/2" Gas Supply 1/2" x 3/8" Shut-off Valve 3/8" Nipple 3/8" Union 3/8" Nipple FP598 Fig. 10 Typical gas supply installation. NOTE: Use an approved outdoor switch. 1. Thread wire through the low voltage wire access hole located on either side of unit. Do not cut wire or insulation on metal edges. Ensure that wire is protected. Run the other end to a conveniently located wall receptacle box. 2. Attach wire to switch and install switch into receptacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. Refer to Figure 11. CAUTION: Do not wire millivolt remote wall switch for gas appliance to a 120v power supply. For lighting instructions, refer to Page 12. Pilot Thermodisk On/Off Switch Valve HV105 Fig. 11 Remote switch wiring. TPTHTHTP NOTE: If glass doors are installed, the unit must be operated with the doors fully open. (Fig. 12) If the doors are not fully open, the thermodisk will automatically turn the unit off. CAUTION: After the unit cools, the burner will automatically come on. OPENCorrect Wrong MD706-7 Fig. 12 Correct door position during operation. 20007114 ODGSR Series Outdoor Gas Fireplace Flame Adjustment For units equipped with Hi/Lo valves, flame adjustment is accomplished by rotating the Hi/Lo adjustment knob located near the center of the gas control. Turn Turn clockwise counterclockwise to lower to increase flame height flame height Fig. 16 Proper pilot flame height. FP581 3/8"-1/2" NOVA SIT Pilot Fig. 15 Flame adjustment knob for SIT820 valve. Flame Characteristics It is important to periodically perform a visual check of the pilot and the burner flames. Compare them to the illustrations below (Figs. 16, 17, 18). If any of the flames appear abnormal call a service person. Red Glow LG319 Fig. 17 ODGSR36A flame appearance. LG320 Fig. 18 ODGSR42A flame appearance. 10 20007114 ODGSR Series Outdoor Gas Fireplace Optional Weather Enclosure Optional Stainless Steel Hood An optional weather enclosure is available to protect the burner when not in use. CAUTION: Do not use the weather enclosure if the unit has glass doors installed. Installation Instructions 1. Turn the unit OFF and allow to cool. 2. Grab the weather enclosure by the handle(s). 3. Slide the top of the weather enclosure up between the back of the surround top and the screen rail. (Fig. 19) 4. Push the bottom of the weather enclosure into the firebox just enough to clear the valve access cover and set down. (Fig. 20) Surround Top Weather Enclosure Screen Rail KT457 Fig. 19 Place top of weather enclosure between surround top and screen rail. Screen Hearth Brick Valve Access Cover KT458 Fig. 20 Push bottom of weather enclosure into firebox. An optional stainless steel hood is available for both the ODGSR36A and ODGSR42A. NOTE: The stainless steel hood may NOT be used when the opt...

Эта инструкция также подходит к моделям:
Камины - ODGSR36A (1.09 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории