Войти:
Оценок - 2, средний балл: 3 ( )

Инструкция по эксплуатации Hearth and Home Technologies, модель GO30MTCH

Производитель: Hearth and Home Technologies
Размер: 5.18 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


wrench. • Place the burner towards the rear and center of the fireplace and connect to the gas line. Follow instructions in “F. Gas Pressure” to check for gas leaks. Figure 4 Placing Vermiculite .Pour vermiculite over the sand in the pans until they are full. See Figure 4. Note: For best results, do not pack down the rock wool. The placement of rock wool can have an effect on flame pattern and may need to be adjusted to achieve a desired appearance. Figure 1 Measure Firebox Figure 5 Placing Rock Wool • Lightly place dime-size pieces of rock wool evenly on top of the sand and vermiculite to achieve a glowing ember effect. See Figure 5. I. For Natural Gas Installation • Pour sand into the burner pans to the point where the burner pipe is covered. See Figure 3. Level the sand from right to left to ensure an even flame pattern. At this point the pan should be half full. • Remove the Platinum Bright Embers™ from the package. For optimum performance peel each piece apart in layers and lightly place on top of the vermiculite and rock wool where the flame is blue. This will achieve the desired realism. • The gas burns at the point of the least resistance. In case of an uneven flame pattern it may be necessary to adjust the materials in the pans (using an object such as a screwdriver) to achieve the desired effect. • Place desired amount of lava granules on the floor of the fireplace. DO NOT ALLOW THE GRANULES TO COME IN CONTACT WITH THE FLAMES. (Lava granules may contain moisture which, when heating, may cause it to pop out during installation and set-up.) Ensure the controls and switches are unobstructed after the granules are installed. • Place logs. See Sections L Thru S. • Place accent logs around burner on floor of fireplace. Figure 3 Sand A spillage test must be made before the installed appliance is left with the consumer. • Close all doors and windows in the home. • Light the log set (see Lighting Instructions). • After three minutes, test with a smoke match, smoke candle, stick incense or cigarette 1 in. below the top of the opening (lintel) moving across the full width. If spillage (smoke down into the room) occurs, it will most likely be near the top, outside corners. Fire Risk Explosion Risk Personal Injury Risk Failure to position the parts in accordance with the diagrams provided with the log packages or failure to use only parts approved with this appliance may result in K. Inspect the Venting System The fireplace venting system is designed and constructed to develop a positive flow adequate to remove flue gases to the outside atmosphere. See fireplace installation instructions. J. Damper Stop Installation Instructions Included in the burner assembly box is a damper stop clamp which attaches to the damper as shown (Figure 6). Install the clamp to the damper ensuring that the minimum requirements (Tables 1 and 2) are achieved. Use a 7/16 in. wrench to secure the clamp to the damper. If the damper clamp provided does not fit your application, other means of securing the proper opening must be provided by the installer. Possible cures if spilling occurs: • The damper needs to be opened further. • The fireplace opening needs to be reduced by adding a drop panel across the top under the lintel. • The air supply from outdoors needs to be increased. Open the outside air kit if the appliance is so equipped, or crack open a door or window. • If necessary, seek expert advice. Do not operate this appliance. Figure 6 Damper Stop Clamp Cleaning • Periodic examination and cleaning of the venting system of the fireplace should be done before initial use and at least annually by a qualified agency. Note: The state of Massachusetts requires that the chimney flue damper, when used with gas logs, be welded open or completely removed. In the Commonwealth of Massachusetts this appliance must be installed by a licensed plumber or gasfitter. L. GO24 Grand Oak Series Logs • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV737 SRV738 SRV736 SRV729 SRV723 SRV722 SRV724 SRV727 SRV728 SRV742 SRV743 M. GO24 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. WARNING Fire Risk Explosion Risk Personal Injury Risk Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. SRV737 SRV738 SRV736 SRV723 SRV722 SRV729 SRV728 SRV724 SRV743 SRV742 N. GO30 Grand Oak Series Logs • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV721B SRV721A SRV726 SRV720 SRV722 SRV723 SRV724 SRV728 SRV727 SRV740 SRV742 SRV743 O. GO30 Grand Oak Series Log Placement Instructions • Place logs EXACTLY as the following photos depict. SRV721A SRV721B SRV720 SRV726 SRV722 SRV723 SRV724 SRV740 SRV728 SRV74...

Эта инструкция также подходит к моделям:
Камины - GO318MTCH (5.18 mb)
Камины - GO330MTCH (5.18 mb)
Камины - GO24MTCH (5.18 mb)
Камины - GO324MTCH (5.18 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории