Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации CFM Corporation, модель SIT 0.820.634 Nova

Производитель: CFM Corporation
Размер: 327.26 kb
Название файла: 8e8d579f-9d7d-51e4-e93a-168a71dbc748.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Warning: always use an approved gas pipe. Never use a conventional 6-inch pipe alone. • Install the first 4-inch B-vent section or flexible aluminum chimney liner. • Fasten the optional 6-inch collar adapter to the stove with the two (2) screws supplied. • Install the sections of the conventional 6-inch pipe. Over the flexible liner. That you want to cover up. OPERATION INSTRUCTIONS Wall thermostat The optional wall thermostat will automatically keep your room at an even temperature. You need to choose a convenient location for the thermostat. Remember that it should be at least 10 feet from the stove and away from direct radiation of the fire. Run the correct gauge wire (see table) from the valve to the thermostat and wire as shown in the diagram.(on next page) To operate your EXCEL-FIRE using the wall thermostat, follow the lighting procedure and set the gas control to the ON position. Simply set your wall thermostat to a comfortable temperature and the stove will do the rest. During the heating season, you do not have to touch the gas control valve. If you would like the stove off for a while, just set the thermostat to its minimum setting. However if you do not need the stove for quite some time, follow the procedure outlined in the SHUTDOWN section. This will extinguish the pilot light as well. DISTANCE DIAMETRE 20 pi 18GA 30 pi 16GA 40 pi 14 GA 50pi 12GA REMOVE THE BLUE JUMPER BETWEEN TP & TPTH SCREWS ON THE GAS VALVE. Optional blower The blower control contains a variable speed switch and a thermal switch. When the stove is operating, the thermal switch will turn on at 110° F, allowing the blower to operate. When the stove cools to 90° F, the thermal switch turns off the blower in about 40 minutes. This prevents the blower from operating when the stove is not in use. The blower not only helps circulate air throughout the room, it also increases the heat output and efficiency of the EXCEL-FIRE. Blower electrical connection Install the blower to the back of the stove using the 4 mounting screws. Than connect the two wires to the motors connectors. If you wish to make a direct electrical connection to the blower without using the six-foot cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location. Remove the power cord and connect the 120V line as per the following procedure: • Unscrew the speed control unit and pull a few inches away from the junction box • Unscrew the two marr connectors attached to the cord (P) and the cord ground • Remove the cord and route the supply line through the same holes • Make the electrical connection with the same wires the cord was attached to • Screw the ground wire to the junction box (G) • Screw the speed control unit back in place PPGCONNECT THE POWER LINE TO THE SAME WIRES THE CORD WAS CONNECTED TO (P) SPEED CONTROLJUNCTION BOX NOTE: If you prefer to use the six-foot cord supplied by Drolet, just connect it to a 120V outlet. Gas connection • Move the EXCEL-FIRE to the desired position and secure in place with four screws. • Connect gas line to the stove using listed connectors • Check the gas line piping for leaks. Use a soap and water solution. WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS. Spill switch The EXCEL-FIRE is fitted with a spill switch. This switch is designed to shut down the unit if the flue system is not venting properly. This is usually due to negative pressure in the home or a bird's nest in the flue. If the unit shuts down by itself without apparent reason, the spill switch may be telling you the unit is not venting properly. Consult your service technician. LIGHTING PROCEDURES Before lighting 1. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 2. Make sure that there are no obstructions in the air intake or venting system. 3. Clear the immediate area of combustible materials, gasoline, and other flammable liquids and vapours. 4. Make sure that the gas log is in its proper place. 5. Remove plastic film on brass trims The first fire During the first few hours of operation the appliance will release an odor. This is caused by the burning off of residual oils used in the manufacturing process and by the curing of the high heat paint. The ceramic glass window may require cleaning after this initial "burn in." Please read the instructions on cleaning in the MAINTENANCE section before doing so. WARNING: If you do not follow these lighting instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. 1. Open the pedestal front panel to reach the control. 2. Make sure the gas control knob is turned to the ‘’OFF’’ position. If it is not, press knob slightly and turn clockwise .. to the "OFF’’ position. Do not force the gas control knob. If the gas control was in the on position you should wait 5 minutes...

Эта инструкция также подходит к моделям:
Камины - SIT 0.820.634 Nova (327.26 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории