Войти:
Оценок - 4, средний балл: 3.5 ( )

Инструкция по эксплуатации Desa, модель (V)3612ST

Производитель: Desa
Размер: 5.62 mb
Название файла: 51f72f10-169e-33d4-4d3f-0505f6e02739.pdf
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


115603-01A OUTSIDE AIR KIT INSTALLATION GAS LINE INSTALLATION 7 OUTSIDE AIR KIT INSTALLATION The installation of the outside air kit must be installed during the rough framing of the fireplace due to the nature of its location. Outside combustion air can be accessed through an exterior wall or a vented crawl space (see Figure 13). CAUTION: Air inlet ducts must not terminate in attic space. The maximum height for the air inlet above the platform of fireplace is a minimum of 3 feet below the chimney cap. For further details on the installation of the outside air kit, please refer to the instructions included with the air kit. Secure Two Collars With Figure 13 - Air Kit Installation Air Inlet Location Must Allow For Bushes Or Snow Air Inlet TerminationDuct Tape or Screws GAS LINE INSTALLATION WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. FOR UNVENTED ROOM HEATERS, ANSI\IAS\AGA Z21.11.2, ARE TO BE INSTALLED IN THIS FIREPLACE. 1. To install, remove the knockout indentation on the refractor (or firebrick) wall located approximately 2 inches above the refractory hearth floor. The knockout indentation must be firmly tapped with any solid object until it is released. Remove fragmented portion of refractory (see Figure 14). 2. Remove gas line cover plate on rear of fireplace and pull out insulation from gas line conduit sleeve, save insulation for reuse. 3. Run gas line into the fireplace through the rear at 111/4" from the floor and through gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 15). Note:Secure incoming gas line to wood framing to provide rigidity for threaded end. 4. Repack insulation around gas line and into sleeves openings. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement. Install the decorative gas appliance or cap off gas line if desired. Outside of Fireplace Gas Line Conduit Remove Insulation Temporarily (Do Not Remove Knockout Replace Screws After Side Firebrick Finished Side Refractory Knockout Plug, Remove by Discard) Removing Gas Line Tapping Lightly Cover Plate With A 1/2" Dowel Figure 14 - Removing Knockout for Gas Line Installation For more information, visit more information, visit NOTICE: BEFORE YOU PROCEED, MAKE SURE YOUR GAS SUPPLY IS OFF! A gas line may be installed for the purpose of installing a vented or vent-free decorative gas appliance available through your local distributor. Use only gas piping approved by local codes. When installing a gas line, a shutoff valve designed for installation outside the appliance is recommended. The gas pipe is intended for connection to a decorative gas appliances that operate from natural or propane/LP fuel only: (1), incorporating an automatic shutoff device and, (2), complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplace, ANSI Z21.60-1990. ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD Figure 15 - Running Gas Line Outside of Fireplace Side Firebrick Finished Side Incoming 1/2" Black Iron Pipe Gas Line Conduit Repack Insulation Seal Opening With Refractory Cement Provide Enough Threaded End For Fitting Connection 115603-01A 88 GASLINEINSTALLATION CHIMNEY PIPE INSTALLATION PIPE INSTALLATION FIRESTOP SPACERS GAS LINE INSTALLATION Continued WARNING:AfterensuringthatthegasvalveisON, testallgaspipingandconnectionsforleaksafterinstallingorservicing.Correctallleaksatonce. Note:AnappropriateDESAhood(seeReplacement and AccessoryParts, page16)mustbeinstalledwhenusinganunventedgaslogset. WARNING:Neveruseanopenflametocheckforaleak.Applyanoncorrosiveleakdetectionfluidtoalljoints.Bubblesformingshowaleak.Correctallleaksatonce. CAUTION:Whenusingadecorativeappliance, thedampermustberemovedorpermanentlylockedin the open position. VENTING INSTALLATION CHIMNEY PIPE INSTALLATION The DESA chimney system is a snap-lock, double wall pipe. It consists of a stainless steel inner flue pipe(s), a galvanized outer pipe, and a wire spacer. Each section of pipe comes in lengths of 12, 18, 36, and 48 inches, but the actual lineal gain for each is measured after each section is fully connected. Lineal gain is the actual measurable length of a part after two or more parts are connected. MODEL NO. DESCRIPTION GAIN V3612ST See-Through" Fireplace 52 3/4" 48-12DM/48-12TM Flue Pipe 46 5/8" 36-12DM/48-12TM Flue Pipe 34 5/8" 24-12DM/48-12TM Flue Pipe 22 5/8" 18-12DM/48-12TM Flue Pipe 16 5/8" 12-12DM/48-12TM Flue Pipe 10 5/8" STL-12D Chase Style Termination 1" to 12" RTL-12D Round Top Termination 7" PIPE INSTALLATION Place pipe assembly (inner and outer with wire spacer) over starter collar. Inner pipe(s) fit inside inner pipe(s). Outer pipe fits outside outer pipe. Begin by aligning hemmed end of inner flue pipe into the inner starting fluepipeoffireplace.Pushdownunti...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории