Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Dimplex, модель CDS8515

Производитель: Dimplex
Размер: 623.75 kb
Название файла: dimplex-tds8515tc.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NO USER-SERVICEABLE PARTS INSIDE Model and Serial Number Information If you have any questions about our products please have the product model and serial numbers available upon calling Dimplex customer service. To locate the model and serial number see below (Figure 1). Figure 1 Part Number Model Number Serial Number Stove Installation ! NOTE: A 15 Amp, 120 Volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker. WARNING: Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire, electric shock or injury to persons. Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock and injury to persons. Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician. 1. Make sure the unit’s Main ON/OFF switch is switched OFF (refer to operating instruction section). 2. Plug the unit into a 15 Amp/120 Volt outlet. If the cord does not reach, you may use an extension cord rated for a minimum of 1875 Watts. Operation To access the controls, go to the back of the stove (Figure 2). A. Main Power ON/OFF Switch The Main Power ON/OFF Switch supplies power to all unit functions (flame, Purifire™, and heater). Figure 2 A B C D E Back View Front View B. Manual Selection Switch To choose between flame effect setting, flame effect with Purifire™ setting, and flame effect with Purifire™ and heat setting. Pressing the switch up (“ I ” position) has the same effect as the ON button on the remote control and pressing the switch down (“ II ” position) has the same effect as the OFF button of the remote control. Pressing the switch up once activates Level 1, twice activates Level 2, three times activates Level 3. Pressing the switch down turns the electric stove OFF. Level 1: The flame effect is turned on and the first red indicator is activated. Level 2: The flame effect remains on, the Purifire™ is activated, and the first and second red indicator lights are activated. Level 3: The flame effect and Purifire™ remain on, the heater is activated, and all three red indicator lights are activated. C. Interior Light ON/OFF Switch The Interior Light On/Off Switch supplies power to the interior light. D. Heater Thermostat Control To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reached the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. E. LED Indicators Indicates the current function of the stove (Figure 3). ! NOTE: The heater may emit a slight, harmless odor when first used. This odor is a normal condition caused by initial heating Figure 3 Level 1 Indicator Level 2 Indicator Level 3 Indicator of internal heater parts and will not occur again. Resetting the Temperature Cutoff Switch This unit is equipped with a thermostat which controls the temperature of the room. It does this by turning the heater on and off. The heater is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Main ON/OFF Switch to OFF and waiting five (5) minutes before switching the unit back on. CAUTION: If you need to continuously reset the heater, unplug the unit and call your local dealer. Remote Control Usage The stove is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m). It does not have to be pointed at the stove and can pass through most obstacles (including walls). It is supplied with one of 243 independent frequencies to prevent interference with other units. The frequency designation is indicated on the back of the transmitter (Figure 4). The remote control operates the stove levels sequentially. The level is increased every time the ON button on the transmitter is pressed. The stove can be turned off at any point by pressing the OFF button on the remote control transmitter. Level 1: The flame effect is turned on and the first red indicator is activated. Level 2: The flame effect remains on, the Purifire™ is activated, and the first and second red indicator lights are activated. Level 3: The flame eff...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории