Войти:
Оценок - 3, средний балл: 3.3 ( )

Инструкция по эксплуатации Desa, модель (V)T32EP

Производитель: Desa
Размер: 4.43 mb
Название файла: 6a4cae12-16f0-58f4-c9c0-3706e060e00b.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Keep this manual for reference. It is your guide to safe and proper operation of this fireplace. WARNING: Any change to this fireplace or its controls can be dangerous. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use pro- pane/LP fuel tank of less than 100 lbs. capacity. 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any phone in your building • immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions • if you cannot reach you gas supplier, call the fire department. 4. Never install the fireplace • in a recreational vehicle • in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front • in high traffic areas 5. This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching. 6. Carefully supervise young children when they are in the room with fireplace. For more information, visit more information, visit 108860 Forr morre iinfforrmattiion,, viisiitt 33 7. Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace. 8. Turn fireplace off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair this fireplace. Have fireplace inspected annually by a qualified service person. 9. You must keep control compartments, burners, and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace. 10. Have venting system inspected annually by a qualified service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 27. 11. Keep the area around your fireplace clear of combustible materials, gasoline, and other flammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around fireplace. 12. Do not use this fireplace to cook food or burn paper or other objects. 13. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this fireplace. Use only the gas type indicated on fireplace nameplate. 14. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. 15. Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service person to arrange for replacement of the unit. 16. Do not operate fireplace if any log is broken. 17. Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this fireplace. 18. Do not operate fireplace with glass door removed, cracked, or broken. SAFETY INFORMATION Continued PRODUCT IDENTIFICATION Figure 1 - Tudor Direct-Vent Fireplace wit Electronic Ignition LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Installation Code (Canada). *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 SAFETY INFORMATION LOCAL CODES PRODUCT IDENTIFICATION Glass Door Assembly Blower Switch (Optional Installation) Control Valve Log Set Grate Assembly Lava Rock Glowing Embers Upper Louver Panel Lower Louver Panel Flue Collar Nailing Flange ON/OFF/REMOTE Switch (Optional Installation) 4 PRODUCT FEATURES PRE-INSTALLATION PREPARATION Location and Space Requirements PRODUCT FEATURES These are a few facts that can help you understand and enjoy your direct-vent fireplace: • The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications. • This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed. • This fireplace does not require electricity to operate. • Only the blower requires...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории