|
Фрагмент инструкции
WARNING: THESE APPLIANCES AREDESIGNED TO OPERATE ON NATURALOR PROPANE GAS ONLY. THE USE OFOTHER FUELS OR COMBINATION OFFUELS WILL DEGRADE THE PERFOR- MANCE OF THIS SYSTEM AND MAY BEDANGEROUS. UNVENTED GAS ROOM HEATER SPECIFICATIONS AND TECHNICAL DETAILS Valve Regulator Pressure Gas Inlet Model No. Gas Type Maximum BTU/HR Operation Ignition Setting Pressure VF4000-CHN-2 Natural 25,000 Manual Piezo 5" w.c. Max 10 ..." w.c. VF4000-CMN-2 Min. 6" w.c. VF4000-CHP-2 Propane/ 25,000 Manual Piezo 10" w.c. Max 13" w.c. VF4000-CMP-2 LPG Min. 11" w.c. WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS PROVIDED IN THIS DOCUMENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OPERATING UNVENTED ROOM HEATER, VOIDING ITS WARRANTY. ANY CHANGE TO THIS HEATER AND/OR ITS OPERATING CONTROLS IS DANGEROUS. IMPROPER INSTALLATION OR USE OF THIS HEATER CAN CAUSE SERIOUS INJURY OR DEATH FORM FIRE, BURNS, EXPLOSION OR CARBON MONOXIDE POISONING. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the heater and have it serviced by a qualified professional, as it may not be operating correctly. • Due to high temperatures, the heater should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in the same room with the heater. • Do not place clothing or other flammable material on or near the heater for the purpose of drying. • Installation and repair should be done by a qualified service person. The heater should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is important that control compartments, burners and circulating air passageways of the heater be kept clean. • Allow the heater to cool before servicing. Always shut off any electricity or gas to the heater while performing service work. • Do not install the VF4000 series heaters in a bedroom or bathroom. • The installation must conform with local codes or, in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1. • The heater and its individual shut-off valve must be disconnected from the gas supply piping system while performing any tests of the gas supply piping system at pressures in excess of 1/2 psig. • The heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. • Any safety screen or guard removed for servicing the heater must be replaced prior to operating the heater. • Keep heater area clear and free from combustibl...
Эта инструкция также подходит к моделям:Камины - VF4000-CHN-2 (1 mb)
Камины - VF4000-CHP-2 (1 mb)
Камины - VF4000-CHN-2 (1 mb)
Камины - VF4000-CHP-2 (1 mb)