Войти:
Оценок - 2, средний балл: 3 ( )

Инструкция по эксплуатации Bryant, модель 359BAV

Производитель: Bryant
Размер: 363.24 kb
Название файла: om359bav-01.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


NOTE: Some filters are marked with an arrow to indicate the proper direction of air flow through the filter. The air flow direction will be towards the blower motor. Make sure filter is installed correctly. Filter Replacement The filter may be installed inside the bottom of the furnace blower compartment, or the filter(s) rack may be installed under the furnace or on either or both sides of the furnace. A plastic end cap(s) is inserted in the filter rack(s) after the filter(s) is installed. The end cap keeps air from escaping around the open end of the filter rack. See Fig. 4 and Fig. 5 for side and bottom locations. Rack end cap is similar for bottom mounted filter rack. Filter rack(s) attached to the outside of the furnace is made so the filter simply slides out one end for removal. 359BAV 5 6 PROPERTY DAMAGE HAZARD Failure to follow this caution may result in increase furnace operating temperatures and shorten the life of the furnace. Filters specified for the furnace are rated at a maximum of 600 FPM air velocity and sized for the furnace’s airflow rate. Replacement filters must be of equivalent type, size, and rating except as described below. Disposable, low--velocity filters may be used to replace washable, high--velocity filters, providing they are sized for 300 FPM or less. If you are uncertain of the type of replacement filter to use, consult the furnace installer or a qualified service agency for assistance. ! CAUTION Filter Replacement -- Bottom or Side Mounted Filter Rack Outside Furnace 1. Turn OFF electric power to furnace. 2. Remove the end cap from the filter rack. 3. Slide the filter out of the filter rack. See Fig. 4. 4. Inspect the filter(s) and replace or clean washable types. If filter is aluminum mesh it should be recoated with filter coating spray. Filter Rack End Cap A07690 Fig. 4 -- Filter Rack Outside Furnace 5. Reinstall the end cap in the filter rack. 6. Turn on electric power to furnace. Filter Replacement -- Bottom Mounted Filter Inside Furnace 1. Turn off electric power to furnace. 2. Remove blower door. 3. Slide filter straight out toward you. See Fig. 5. 4. Inspect the filter(s) and replace or clean washable types. If filter is aluminum mesh it should be recoated with filter coating spray. 5. Replace blower door. 6. Turn on electric power to furnace. 9. Center Clip side--to--side (228.6 mm) A07691 Fig. 5 -- Bottom Mounted Filter Inside Furnace External Filter Rack A plastic end cap is inserted in the filter rack after the filter is installed. The end cap keeps air from escaping around the open end of the filter rack. See Fig. 4 for removal of filter. Filter racks attached to the furnace are made so the filter simply slides out one end for removal. 1. Turn OFF electric power to furnace. 2. Remove the end cap from the filter rack. 3. Slide the filter out of the filter rack. 4. Inspect the filter(s) and replace or clean washable types. If filter is aluminum mesh it should be recoated with filter coating spray. 5. Reinstall the end cap in the filter rack. 6. Turn furnace on. Internally Mounted Filter 1. Turn OFF power to furnace. 2. Remove blower door. 3. Slide filter straight out toward you. (See Fig. 5.) 4. Inspect the filter(s) and replace or clean washable types. If filter is aluminum mesh it should be recoated with filter coating spray. 5. Replace blower door. 6. Turn on electric power to furnace. Lubrication The blower motor and the combustion air blower are pre--lubricated by the manufacturer and DO NOT require oiling. Qualified Service Agency Checks When the furnace is being inspected for condition and operation have the Qualified Service Agency check the following items. 1. Check all flue gas passages including main and pilot burners, heat exchanger, and vent. 2. Check electrical wiring and connections. 3. Check supply and return air ducts for leakage, blockage and connections to furnace. 4. Check circulating air blower wheel and motor. Clean them if required. 5. Perform an operational checkout on the furnace to be sure safety controls function and that furnace operates properly. For additional information, the Qualified Service Agency can consult the installation instructions for the furnace. 359BAV Table 1 – Recommended Filter Sizes Nominal Air Flow Cubic Feet per Minute (CFM) Recommended Filter Sizes Nominal Size (in./mm) Disposable Filters Cleanable Filters 800- -- 900 20 x 25 (508 x 635) (1 Req.) 14 x 25 (356 x 635) (1 Req.) 1100- -- 1300 14 x 25 (356 x 635) (2 Req.) 14 x 25 (356 x 635) (1 Req.) 1300- -- 1500 16 x 18 (406 x 457) (2 Req.) 16 x 18 (406 x 457) (1 Req.) 1500- -- 1700 20 x 25 (508 x 635) (2 Req.) 20 x 25 (508 x 635) (1 Req.) 1900- -- 2100 20 x 30 (508 x 762) (2 Req.) 20 x 25 (508 x 635) (1 Req.) 2300- -- 2500 20 x 30 (508 x 762) (2 Req.) 24 x 30 (610 x 762) (1 Req.) 7 359BAV 359BAV359BAV Heating& CoolingSystems TO OBTAIN INFORMATION ON PARTS: Consult your installing dealer or classified section of your local telephone directory under the “Heating Equip...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории