|
Фрагмент инструкции
See the appropriate sections of this manual for instructions. 8. WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur. This is an vent-free gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to installation guidelines. 9. 10. Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. 11. Young children should be carefully supervised when they are in the same room with the appliance. 12. Do not place clothing or other flammable material near the appliance. 3 4 IMPORTANT SAFETY INFORMATION Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Any safety screen or guard removed for servicing, must be replaced prior to operating the heater. This vent-free gas heater is intended to be smokeless. If logs appear to smoke, turn off the heater and call a qualified service person. Initial burn off may cause slight smoke and odor during the first four hours of operation. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. For elevations above 2,000 feet, input ratings should be reduced 4 percent for each 1,000 feet above sea level. Refer to the National Fuel Gas Code. The heater and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Do not use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water. PRODUCT FEATURES 13. 14. 15. 16. 17. 18. 19. FIGURE 1. 9740 Vent-Free Pedestal Gas Heater. Features: • Heating Efficiency - 99.9% • Wide BTU Range: 10,000 - 39,900. • Safe Operation - Oxygen Depletion Sensor (ODS). • No Electricity Required. • Fibre Ceramic Logs. • Push-Button Piezo Ignitor. • Clean Operation. • Wide Bay Front. • Compact Design. • Easy Operation. • Heats up to 1,200 square feet. SPECIFICATIONS Natural Gas Manifold Pressure Setting 4" w.c. Gas Inlet Pressure Maximum 10-1/2" w.c. Minimum 5" w.c. Gas Rate Number Model Number Type Max BTU/Hr Min BTU/Hr of Burners 9740N Manual 39,900 10,000 2 Propane / LPG Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c. Manifold Pressure Setting 10" w.c. Gas Inlet Pressure Maximum 13" w.c. Minimum 11" w.c. Gas Rate Number Model Number Type Max BTU/Hr Min BTU/Hr of Burners 9740L Manual 39,900 10,000 2 Controls -Main control has 4 positions: 1. OFF -All gas to the gas logs is shut off at the control 2. IGN -Piezo ignitor allows ignition of the pilot without the use of matches or batteries 3. PILOT -Valve position to light / maintain a standing pilot 4. ON -Gas flow to complete system, front burner ignition Front Burner Control Knob -Infinite control, rotate clockwise to minimum rate and counter clockwise for maximum rate. Rear Burner Control Knob -Has 3 positions: 1. OFF -Gas to rear burner is shutoff at control 2. ON/MAX -Maximum gas flow to rear burner 3. MIN -Minimum gas flow rate to rear burner CONTENTS 9740L and 9740N Unvented Gas Heaters 1. Packet containing Homeowners/Installation instructions. 2. Log box containing four (4) fiber ceramic logs, refer to installation instructions. 3. Unvented gas heater. CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS TO PREVENT SKIN IRRITATION FROM LOOSE FIBERS. LOGS ARE FRAGILE, HANDLE WITH CARE.CAUTION Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found. 5 ITEMS REQUIRED FOR INSTALLATION ITEMS REQUIRED FOR INSTALLATION Ensure that the following items are available before proceeding with installation: • External regulator (for propane/LPG only) • Manual shutoff valve • Piping which complies with local codes • Sediment trap • Pipe sealant approved for use with • Pipe wrench propane/LPG (resistant to sulfur compounds) CODES Adhere to all local codes or in their absence, the latest edition of THE NATIONAL FUEL GAS CODE ANSI Z223.1 or NFPA54 which can be obtained from: American National Standards Institute, Inc. National Fire Protection Association, Inc. 1430 Broadway or Batterymarch Park New York, NY 10018 Quincy, MA 02269 WARNINGDue to high temperatures, do not install the heater: • Where curtains...
Эта инструкция также подходит к моделям:Электрообогреватели - A9740L (413.2 kb)
Электрообогреватели - C9740L (413.2 kb)
Электрообогреватели - C9740N (413.2 kb)
Электрообогреватели - G9740L (413.2 kb)