|
Фрагмент инструкции
Release gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 4 through 8. • If knob does not pop up when released, STOP and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. Turn gas control knob counterclockwise to “ON”. Close the cabinet door. Set thermostat to desired setting. TO TURN OFF GAS TO APPLIANCE 1. Set the thermostat to it’s lowest setting. 3. Push in gas control knob slightly and turn clockwise 2. Open cabinet door. to “OFF”. Do not force. 4. Close cabinet door. Page 10 LIGHTING INSTRUCTIONS MODEL: W251F, W252F / W351F, W352F / W501F, W502F FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS Outlet (Manifold)Pressure Tap 1. STOP! Read the information on the safety label. 2. Open cabinet door. 3. Turn temperature control knob to “LO”. 4. Depress and turn gas control knob clockwise to “OFF”. Temp. Control Knob NOTE: Knob can not be turned from “PILOT” to “OFF” unless knob is pushed in slightly. Do not force. 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the information on the safety label. If you don’t smell gas, go to the next step. 6. Locate the pilot. (Follow metal pilot tube from gas control). 7. Turn gas control knob counterclockwise to “PILOT”. Gas Control KnobInternal Outlet Pressure Regulator Pilot is located on side of burner 8. Depress gas control knob and hold in. Immediately light the pilot with a match. Continue to hold the gas control knob in for about one (1) minute after the pilot is lit. Release gas control knob and it will pop back up. Pilot should remain lit. If pilot goes out, repeat steps 4 through 8. • If knob does not pop up when released, STOP and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 9. Turn gas control knob counterclockwise to “ON”. 10. Turn temperature control knob to desired setting, usually a setting of 5 or 6 is satisfactory. 11. Close the cabinet door. TO TURN OFF GAS TO APPLIANCE 1. Open the cabinet door. 3. Push in gas control knob slightly and turn clockwise 2. Turn temperature control knob clockwise to “OFF”. Do not force. to “LO”. 4. Close cabinet door. Page 11 PILOT ADJUSTMENT MAINTENANCE INSTRUCTIONS Locate the pilot adjustment screw on the valve. The pilot 1. Installation and repair should be done by a qualified flame should surround at least the top 3/8” of the powerpile service person. The appliance should be inspected before (pilot generator) or thermocouple (see below). The pilot is use and at least annually by a professional service person. unregulated so it will be operating at inlet line pressure (Max. More frequent cleaning may be required due to excessive 7” w.c. for natural gas and 11” w.c. for propane). To decrease lint from carpeting, bedding material, etc. It is the pilot flame, turn the screw clockwise (approximately seven imperative that control compartments, burners, pilot to nine full turns to bottom of pilot light channel) until you burners, circulating air passageways and venting systems produce sufficient flame at the minimum noise level. of the appliance be kept clean. PILOT FLAME ADJUSTMENT 3/8 TO 1/2 INCH PILOT FLAME SHOULD ENVELOP 3/8 TO 1/2 INCH OF THE TIP OF THE GENERATOR. 2. If the appliance has been equipped with the optional WFF81-C fan kit assembly, the bearings of the motor should be oiled every six months with approximately 2 drops of S.A.E. 20 oil. 3. The appliance area must be kept clear an...
Эта инструкция также подходит к моделям:Электрообогреватели - W251F (208.53 kb)
Электрообогреватели - W351F (208.53 kb)
Электрообогреватели - W352F (208.53 kb)
Электрообогреватели - W355F (208.53 kb)