Инструкция по эксплуатации Gas-Fired Products, модель LTS 90

Производитель: Gas-Fired Products
Размер: 1.33 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


See Figures b and c. 4. Heaters subject to vibration must be provided with vibration isolating hangers. 5. Heaters must not be supported by gas or electric supply lines and must be suspended from a permanent structure with adequate load capacity. Space-Ray recommends that the body sections be hung by chains with turnbuckles. This will allow slight adjustments after assembly and heater expansion/contraction during operation. 1/2" diameter hole t? Tube Support/Hanger Bracket (End View) 3/16" xr wide Flat Bar \ 5/16" Screw U Nut & Washer TYPICAL SUSPENSION METHODS Form #43155010 Feb-04 18) INCLINED MOUNTING INSTRUCTIONS (LTS ONLY) These inclined mounting instruction relate to LTS series heaters (straight tubes) that do not utilize the elbow accessory. These heaters have been tested and design certified by the CSA for 2”/12" pitch (10°) inclined mounting of the heater from the control box to the draft inducer assembly as shown in the following diagram. Draft Inducer Body Sections Control Box DETAIL A Draft Inducer Assembly See Detail The purpose of this type mounting is to allow the heater to be mounted in the plane of the roof (particularly in modern “Butler” type buildings frequently used today). This will typically put the heater out of the way while still providing the warmth and comfort. The heater can be inclined upwards from the control box to the draft inducer at a distance of 2 inches up for every linear foot of the heater length. The total rise for each draft inducer is tabulated in the table below: Speed Clips Inclined Mounting Reflector These parts are included In the inclined mounting kit. TOTAL DRAFT INDUCER HEIGHT ABOVE HORIZONTAL FOR 2”/12” PITCH INSTALLATIONS Tube Length Models 15 Ft. 20 Ft. 25 Ft. 30 Ft. 35 Ft. 40 Ft. 45 Ft. 50 Ft LTS 40-LTS 75 30” 40” 50’ 60” LTS 80-LTS120 60” 70” LTS125-LTS130 60” 70" 80” 90” 100” LTS140-LTS175 t o 00 90” 100” The heater is subject to all other requirements presented in these Installations Instructions, particularly the Clearances to Combustibles. If you plan to use this type of installation, order the Space Ray Inclined Mounting Kit, Part #43238000. 19) MINIMUM CLEARANCES TO COMBUSTIBLES Minimum clearances to combustibles shall be measured from the outer surfaces as shown in the following diagram: I ' ■ l->End Side <- Ceiling I Below Horizontal Front ^ Side MINIMUM CLEARANCES TO COMBUSTIBLES Mounted Horizontally Angle Mounted at 45° Model No. Sides Celling* Below Ends 45° Front 45* Rear LTS/LTU 40, 50 27” 6” 40” E o CO 48” 12” LTS/LTU 60, 75 27” 6” 60” 30” 48” 12” LTS/LTU 80, 90 52” 6’ 84” 30’ 52’ 12” LTS/LTU 100 66” 6” 88” 40” 66" 20” LTS/LTU 110,120,125,130 66” 6" 101” 41” 66” 20” LTS/LTU 140,150,160,175 84" 6” 106” 48” 84" 24” * When used indirect vented, the clearance must be: 12” for LTS40-75 and 18’ for LTS/LTU80-175. If optional corner reflectors are not used, the clearance must be 18” NOTE...

Эта инструкция также подходит к моделям:
Электрообогреватели - LTS 100 (1.33 mb)
Электрообогреватели - LTS 110 (1.33 mb)
Электрообогреватели - LTS 120 (1.33 mb)
Электрообогреватели - LTS 125 (1.33 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории