Войти:
Оценок - 6, средний балл: 4 ( )

Инструкция по эксплуатации Gas-Fired Products, модель LTS 160

Производитель: Gas-Fired Products
Размер: 1.33 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Follow the instruction below for joining these sections. 1. Join the tube flanges of the body sections together with the gaskets in between. Secure the flanges with the У4-20 screws and locknuts provided in the 5’ body package. 2. Pull the reflector onto the 15’ body section over the reflector on the 5’ body section to maintain approximately an one-inch overlap. Secure the reflectors by sliding the speed clips on the reflector edges as show in the diagram. One speed clip is required for each side of the reflector. Tighten the reflector clamps once the reflectors are secured with the speed clips. 3. Assemble the control box, draft inducer, and other components as previously described in the heater assembly instructions. 7) LTS 40-175 SERIES - SPECIFICATIONS Model No. Btu/hr Input Flue Restrictor Plate I.D. & Part # Orifice Size Minimum Mounting Height Natural Gas Propane Gas @Horizontal @45° Angle LTS40 40,000 1” #42741040 #31 (0.120) #49 (0.073) 10 feet 9 feet LTS50 50,000 1-1/8” #42741030 3.3mm (0.130) #46 (0.081) 11 feet 10 feet LTS60 60,000 1-7/32” #42741020 #27 (0.144) #43 (0.089) 12 feet 11 feet LTS75 75,000 1-7/16” #42741010 #20 (0.161) #39 (0.099) 13 feet 12 feet LTS80 80,000 1-1/2” #42741050 #19 (0.166) #38 (0.102) 13 feet 12 feet LTS90 90,000 1-1/2” #42741050 #16 (0.177) #36 (0.106) 13 feet 12 feet LTS100 100,000 1-5/8” #42741060 #14 (0.182) #33 (0.113) 13 feet 12 feet LTS110 110,000 1-3/4” #42741070 #10 (0.194) #31 (0.120) 14 feet 13 feet LTS120 120,000 1-3/4” #42741070 13/64 (0.203) 1/8 (0.125) 14 feet 13 feet LTS125 125,000 1-7/8” #42741080 #5 (0.206) #30 (0.129) 14 feet 13 feet LTS130 130,000 1-7/8” #42741080 #4 (0.209) 3.3mm (0.130) 14 feet 13 feet LTS140 140,000 2-1/32” #42741090 5.5mm (0.216) #29 (0.136) 15 feet 14 feet LTS150 150,000 2-1/32” #42741090 5.7mm (0.224) #28 (0.140) 15 feet 14 feet LTS160 160,000 2-1/4” #42741100 5.8mm (0.228) #2127 (0.144) 15 feet 14 feet LTS175 175,000 2-1/4” #42741100 “C” (0.242) 3.8mm (0.150) 15 feet 14 feet Type Gas-PIpe Tube Flue Fresh Air Electrical Current Gas: Connection: Diameter: Connection: Connection: Supply: Rating: Natural or Propane W’NPT (Female) 4” 6" Round * 6’ Round * 120 Volt, 60Hz, 1 Phase 2.6 Amp Fuse Rating: Ignition System: In-line: 2 Amp 250V (for 24V Circuit) Spark Module: 3 Amp 250V (for 24V Circuit) Direct Spark (with 30-second prepurge period) * 4’ Round for Models LTS40-75 8) A) LTS 40-175 SERIES - PACKING LIST Control/Draft Inducer Package OTY Control Box Assembly 1— Draft Inducer & Junction Box Assembly .JP.a.^?.9.?.iS!i..^fe?.^..a.!..rifttl.t.)...........................1_ Flue Restrictor Plate (attached to blower housing with 3 lockouts).............................1 Plastic Vacuum Air Tube (#03988120)...........................................................................1 4" x 6” Starting Collar (#42892000).................................................................................1 Control Fastener Kit (#429...

Эта инструкция также подходит к моделям:
Электрообогреватели - LTS 100 (1.33 mb)
Электрообогреватели - LTS 110 (1.33 mb)
Электрообогреватели - LTS 120 (1.33 mb)
Электрообогреватели - LTS 125 (1.33 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории