In normal use: 1. Turn the AC circuit breaker to the OFF position. 2. Disconnect all electrical loads from panel receptacles. Disconnect DC battery charging cables. 3. Turn the engine switch to the OFF position. 4. Turn the fuel valve to the OFF position. MAINTENENCE Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform the service and inspection at the intervals shown in the Maintenance schedule below. Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. NOTICE Use only genuine factory parts or their equivalent for maintenance or repair. Replacement parts which are not of equivalent quality may damage the generator. 14 Maintenance Schedule Notes 1) Service more frequently when used in dusty areas. 2) These items should be serviced by an authorized generator dealer, unless owner has proper tools and is mechanically proficient. 3) For professional commercial use, log hours of operation to determine proper maintenance intervals. Engine oil change Drain the oil while the engine is warm to assure rapid and complete draining. 1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil. 2. Reinstall the drain plug and sealing washer. Tighten the plug securely. 3. Refill with the recommended oil and check the level. Oil capacity: See specifications. (Page 21) Used motor oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods. Although this is unlikely unless you handle used oil on a daily basis, it is still advisable to thoroughly wash your hands with soap and water as soon as possible after handling used oil. 15 Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in a sealed container to your local service station or recycling center for disposal. Do not throw it in the trash or pour it on the ground. Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Use only soapy water or nonflammable solvent. NOTICE Never run the generator without the air cleaner. Rapid engine wear will result. 1. Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2. Wash the element in a solution of household detergent and warm water, then rinse thoroughly; or wash in nonflammable or high flash point solvent. 3. Allow the element to dry thoroughly. 4. Soak the element in clean engine oil and squeeze out the excess oil. The engine will smoke during initial start-up if too much oil is left in the element. 5. Reinstall the air cleaner element and the cover. 16 Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water, which may be in the fuel tank, from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1. Turn the fuel valve to the OFF position. Remove the sediment cup, O-ring, and filter. 2. Clean the sediment cup, O-ring, and filter in nonflammable or high flash point solvent. 3. Reinstall the filter, O-ring, and sediment cup. 4. Turn the fuel valve ON and check for leaks. Spark Plug Service Recommended spark plugs: MP160; BPR6ES (NGK) MP240, MP340, MP390; BPR5ES (NGK) MP270; BP6ES (NGK) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler. 1. Remove the spark plug cap. 2. Clean any dirt from around the spark plug base. 3. Use the wrench supplied in the tool kit to remove the spark plug. 4. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. 5. Clean the spark plug with a wire brush if it is to be reused. 6. Measure the plug gap with a feeler gauge. The gap should be: 0.70-0.80 mm (0.028-0.031 in) 7. Correct as necessary by carefully bending the side electrode. 8. Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 9. After the spark plug is seated, tighten with a spark plug wrench to compress the washer. • If installing a new spark plug, tighten 1/2 turn after the spark plug seats to compress the washer. • If reinstalling a used spark plug, tighten 1/8-1/4 turns after the spark plug seats to compress the washer. 17 NOTICE The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and could damage the engine. Never use spark plugs which have an improper heat range. Use only the recommended spark plugs or equivalent. TRANSPORTATION/STORAGE When transporting the generator, turn the engine switch and the fuel valve OFF....

Эта инструкция также подходит к моделям:
Электрогенераторы - QB3300 (1.24 mb)
Электрогенераторы - QB1300 (1.24 mb)
Электрогенераторы - QB2800 (1.24 mb)
Электрогенераторы - QB7700 (1.24 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории