Войти:
Оценок - 4, средний балл: 4.8 ( )

Инструкция по эксплуатации Bryant, модель ASPAS1BBA015

Производитель: Bryant
Размер: 817.58 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The requirement is limited to 15 and 20 ampere, 125 volt circuits. There is no prohibition against providing AFCI protection on other circuits or in locations other than bedrooms. Because circuits are often shared between a bedroom and other areas such as closets and hallways, providing AFCI protection on the complete circuit would comply with 210.12. If during the installation of the Bryant Home Standby system the decision is made to provide back up power to a bedroom branch circuit, then the circuit breaker in the Bryant Transfer Switch should be replaced with an Arc Fault Circuit Interrupter. It is most important that breakers only be switched like for like. For instance, if replacing a 15A breaker, it MUST be replaced with a 15A AFCI breaker. Likewise, a 20A breaker MUST be replaced with a 20A AFCI. These AFCI breakers are available at the nearest electrical wholesaler or hardware store. Siemens Item # Description Q115AF 15A Single Pole AFCI Q120AF 20A Single Pole AFCI 4 Bryant Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Bryant 5 1.4 THE GENERATOR Exhaust Enclosure Oil Dipstick Data Decal Control Panel Fuel Regulator Fuel Inlet GFCI Outlet Oil Filter Battery Compartment Exhaust Enclosure Oil Filter Battery Compartment Fuel Inlet GFCI Outlet Control Panel Data Decal Oil Dipstick Fuel Regulator Composite Base Figure 1.2 – 12 kW and 15 kW, V-twin GT-990 Engine Figure 1.1 – 7 kW, Single Cylinder GH-410 Engine Lifting holes (4 places) Lifting holes (4 places) Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators 1.5 SPECIFICATIONS • 1.5.1 GENERATOR Model ASPAS1BBA007 ASPAS1BBA012 ASPAS1BBA015 Rated Max. Continuous Power Capacity (Watts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP Rated Voltage 120/240 120/240 120/240 Rated Max. Continuous Load Current (Amps) 120 Volts** 50.0 NG/58.3 LP 100.0 NG/100.0 LP 108.3 NG/125.0 LP 240 Volts 25.0 NG/29.2 LP 50.0 NG/50.0 LP 54.2 NG/62.5 LP Main Line Circuit Breaker 30 Amp 50 Amp 65 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60 Hz Power Factor 1 1 1 Recommended Air Filter Bryant Part # 0C8127 Bryant Part # 0C8127 Bryant Part # 0C8127 Battery Requirement Group 26 Group 26 Group 26 (At 0° F -17.8° C) 12 Volts and 12 Volts and 12 Volts and 350 Cold-cranking 525 Cold-cranking 525 Cold-cranking Amperes Minimum Amperes Minimum Amperes Minimum Weight 375 Pounds 470 Pounds 487 Pounds Output Sound Level @ 23 ft (7m) at full load 68 db (A) 70.5 db (A) 71.5 db (A) Normal Operating Range -20°F (-28.8°C) to 104°F (40°C) * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60° F) ambient temperature. ** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each circuit must not exceed the value stated for 240 volts. • 1.5.2 ENGINE ASPAS1BBA007 ASPAS1BBA012 ASPAS1BBA015 Type of Engine GH-410 GT-990 GT-990 Number of Cylinders 1 2 2 Rated Horsepower 14.5 @ 3,600 rpm 30 @ 3,600 rpm 30 @ 3,600 rpm Displacement 410cc 992cc 992cc Cylinder Block Aluminum w/Cast Iron Sleeve Aluminum w/Cast Iron Sleeve Aluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valves Overhead Valves Overhead Valves Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Recommended Spark Plug RC14YC RC12YC RC12YC Spark Plug Gap 0.76 mm (0.030 inch) 0.508 mm (0.020 inch) 0.508 mm (0.020 inch) Compression Ratio 8.6:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc 12Vdc Oil Capacity Including Filter Approx. 1.5 Qts Approx. 1.7 Qts Approx. 1.7 Qts Recommended Oil Filter Bryant Part # 70185D Bryant Part # 70185D Bryant Part # 70185D Recommended Air Filter Bryant Part # 0C8127 Bryant Part # 0C8127 Bryant Part # 0C8127 Operating RPM 3,600 3,600 3,600 1.6 SYSTEM SET LED The “System Set” LED is lit when all of the following conditions are true: 1. The AUTO/OFF/MANUAL switch is set to the AUTO position. 2. The utility voltage being supplied to the unit is being sensed by the PCB. If the utility sense voltage is not connected to the unit or if it is below 168 volts AC, then the system set light will flash rapidly. This indicates that if the AUTO/OFF/ MANUAL switch is placed in the Auto position, the generator will start. 3. The “Not In Auto” dip switch is set to the OFF position on the control board. 6 Bryant 4. No alarms are present, for example, low oil pressure, high temperature, etc. 1.7 FUEL REQUIREMENTS AND RECOMMENDATIONS With LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resources B...

Эта инструкция также подходит к моделям:
Электрогенераторы - ASPAS1BBA007 (817.58 kb)
Электрогенераторы - ASPAS1BBA012 (817.58 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории