These starting aids will reduce the efficient working life of the engine. 5. MECHANICAL 6. CHEMICAL Fuels, oils coolants, lubricants and battery electrolyte used in this generating set are typical of the industry. However they can be hazardous to personnel if not treated properly. • Do not swallow or have skin contact with fuel, oil, coolant, lubricants and battery electrolyte. If swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact, wash with soap and water. • Do not wear clothe that has been contaminated by fuel or lube oil. • Wear an acid resistant apron and face shield or goggles when servicing the battery. If electrolyte is spilled on skin or clotting, flush immediately with large quantities of water. • Always keep good ventilation when the equipment is working. Carbon Monoxide inhalation cause death. Always maintain inspection routine of the exhaust system. AR-EXP-CUMMINS-07-00 OWNERS MANUAL Page 8 7. NOISE Generating sets that are not equipped with sound attenuating enclosures can produce noise levels in excess of 105 dBA. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. • Ear protection must be worn when operating or working around an operating set. 8. ELECTRICAL Safe and efficient operation of electrical equipment can be achieved only if the equipment is correctly installed, operated and maintained. • The generating set must be connected to the load only by trained and qualified electricians who are authorized to do so, and in compliance with relevant electric codes, standards and other regulations. • Ensure the generating set, is effectively grounded/earthed in accordance with all relevant regulations prior operation. • The generating sets should be shutdown with the battery negative (-) terminal disconnected prior to attempting to connect or disconnect load connections. • Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground. • Do not touch electrical energized parts of the generating set and/or interconnecting cables or conductors with any part of the body or with any non insulated conductive object. • Place the control panel cover as soon as connection or disconnection of the load cables is complete. Do not operate the generating set without the cover securely on place. • Connect the generating set only to loads and/or electrical systems that are compatible with it’s electrical characteristics and that are within it’s rated capacity. • Be sure all power is disconnected from the electrical equipment being serviced. • Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut, abraded or otherwise degraded. Replace terminals that are worm, discolored or corrode. Keep terminals clean and tight. • Insulate all connections and disconnected wires. • Use only class BC or Class ABC extinguishers on electrical fires. AR-EXP-CUMMINS-07-00 OWNERS MANUAL Page 9 9. FIRST AID FOR ELECTRIC SHOCK Identification / look out for: • Unconsciousness and Burns • Establish site of entry and exit of electric shock What to do: • Switch off the main switch. • Break the contact between electrical source and patient using dry non-conductive object like wooden stick. • Call for help. • If breathing and heartbeat has stopped begin CPR 1. CALL Check the victim for unresponsiveness. If there is no response, Call 911 and return to the victim. In most locations the emergency dispatcher can assist you with CPR instructions. 2. BLOW Tilt the head back and listen for breathing. If not breathing normally, pinch nose and cover the mouth with yours and blow until you see the chest rise. Give 2 breaths. Each breath should take 1 seconds. 3. PUMP If the victim is still not breathing normally, coughing or moving, begin chest compressions. Push down on the chest 11/2 to 2 inches 30 times right between the nipples. Pump at the rate of 100/minute, faster than once per second. CONTINUE WITH 2 BREATHS AND 30 PUMPS UNTIL HELP ARRIVES. In unconscious patient with intact breathing and pulse recovery position ensures the prevention of tongue falling back and blocking the airway. What to do: • Place the patient on their back. • Lift the chin to ensure the air way is open. • Patient's arm on your side should be positioned so as to make a right angle with his body, with elbow bent and palm facing out. • Patient's other arm on opposite side should be placed across the chest, with back of their hand against the cheek on your side of the patient. • Pull up the patient's knee joint (side away from you) as it bends with the foot flat on the ground. • Roll over the patient in this position towards your side. • By tilting the patient's head back ensure that the airway is open. AR-EXP-CUMMINS-07-00 OWNERS MANUAL Page 10 10. SPECIAL CONSIDERATIONS FOR BATTERY CAUTION – The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corr...

Эта инструкция также подходит к моделям:
Электрогенераторы - ACUM210 (2.11 mb)
Электрогенераторы - ACUM140 (2.11 mb)
Электрогенераторы - ACUM185 (2.11 mb)
Электрогенераторы - ACUM65 (2.11 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории