Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Briggs & Stratton, модель 01971

Производитель: Briggs & Stratton
Размер: 1.35 mb
Название файла:
Язык инструкции:enesca
Перейти к скачиванию



Фрагмент инструкции


Check tool or appliance for actual wattage. 9 Portable Generator GENERAL MAINTENANCE RECOMMENDATIONS The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a damaged or defective generator. Engine Maintenance See engine owner’s manual for instructions. CAUTION Avoid prolonged or repeated skin contact with used motor oil. • • Used motor oil has been shown to cause skin cancer in certain laboratory animals. Thoroughly wash exposed areas with soap and water. KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS. Generator Maintenance Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material. NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings. WARNING Unintentional sparking can result in fire or electric shock. WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. Generator Cleaning • Use a damp cloth to wipe exterior surfaces clean. CAUTION Improper treatment of generator can damage it and shorten its life. • • DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors. DO NOT insert any objects through cooling slots. • Use a soft bristle brush to loosen caked on dirt or oil. • Use a vacuum cleaner to pick up loose dirt and debris. • Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed. 10 Portable Generator STORAGE The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined in “Generator Cleaning”. • Check that cooling air slots and openings on generator are open and unobstructed. WARNING Storage covers can be flammable. • DO NOT place a storage cover over a hot generator. • Let equipment cool for a sufficient time before placing the cover on the equipment. Engine Storage See engine owner’s manual for instructions. Other Storage Tips • To prevent gum from forming in fuel system or on essential carburetor parts, empty all three supplied fuel stabilizer containers into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor.The unit and fuel can then be stored for up to 24 months.Additional fuel stabilizer can be purchased locally. • DO NOT store fuel from one season to another unless it has been treated as described above. • Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it's used with this unit. • Store unit in a clean and dry area. 11 Portable Generator TROUBLESHOOTING Problem Cause Correction No AC output is available, but generator is running. 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cord set. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact Authorized service facility. 3. Check and repair. 4. Connect another device that is in good condition. Generator runs good at no-load but "bogs" down" when loads are connected. 1. Short circuit in a connected load. 2. Generator is overloaded. 3. Shorted generator circuit. 1. Disconnect shorted electrical load. 2. See "Don't Overload Generator". 3. Contact Authorized service facility. Generator will not start; or starts and runs rough. Low oil level. Fill crankcase to proper level or place generator on level surface. Generator shuts down during operation. 1. Out of fuel. 2. Low oil level. 1. Fill fuel tank. 2. Fill crankcase to proper level or place generator on level surface. Generator lacks power. Load is too high. See "Don't Overload Generator". 12 Portable Generator NOTES 13 Portable Generator NOTES 14 BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s), of the equipment that is defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under thi...

Эта инструкция также подходит к моделям:
Электрогенераторы - 01970 (1.35 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории