Войти:
Оценок - 5, средний балл: 3.8 ( )

Инструкция по эксплуатации Briggs & Stratton, модель TML-4000

Производитель: Briggs & Stratton
Размер: 846.53 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If more than one operator is expected to use a machine at different times in the same work shift, each operator is expected to follow all safety rules and instructions in the operator's manual. That means every new operator should perform a pre- operation inspection, function tests and a work place inspection before using the machine. Setup Make sure the machine is set up according to the Setup procedure in the Function Tests section. Starting the Engine 1 Make sure the circuit breaker light switches are in the off position. 2 At the control panel, turn the key or turn the switch to the run position. The glow plug light will come on. 3 Wait for the glow plug light to go off. 4 Turn the key or turn the switch to start. Note: If the key or switch is not turned to start within 10 seconds of the glow plug light going off, the engine may fail to start. If this happens, turn the key or switch to the off position and repeat the procedure. Note: If the glow plug light is flashing during the preheat cycle, the battery is low. Operation of Lights 1 Turn on the lights using the circuit breaker switches located on the control panel. Each switch corresponds to one of the lamps. Note: The lights can take up to 20 minutes to reach full intensity. Note: If the lights are turned off and turned back on while they are still warm, they will not light up again for 20-30 minutes. 2 Turn the lights off by turning the circuit breaker switches to the off position. Make sure the lights are turned off before shutting down the engine. Part No. 97600 Genie TML-4000 and TML-4000N Operator's Manual Third Edition • Second Printing OPERATING INSTRUCTIONS To Raise the Mast 1 Unlock the mast hold-down latch. 2 Turn the Raise/Lower winch handle clockwise until the mast reaches the full vertical position and the front spring latch locks the mast firmly in place. To Extend the Mast 1 Turn the Extend/Retract winch handle clockwise to extend the mast sections. 2 Approximately 6 inches / 15 cm below full mast extension, the lamp fixture will begin to tilt. The more the winch handle is turned, the greater the tilt, until the mast is fully extended and the lights are positioned. Note: To adjust the lights after the mast is fully extended, slowly lower the mast by turning the winch handle counterclockwise until the lights are in the desired position. To Rotate the Mast 1 Press and hold the mast rotation lever and rotate the mast to the desired position. 2 Release the lever. To Stow the Mast 1 Press and hold the mast rotation lever and rotate the mast to its original position. Line up the black arrows on the front of the mast. 2 Turn the Extend/Retract winch handle counterclockwise until the mast sections retract. The mast is fully retracted when the blue arrows on the side of the mast are lined up. 3 Pull and hold the mast release latch below the control panel. 4 Turn the Raise/Lower winch handle counterclockwise and lower the mast completely into the transport cradle. Note: If the mast has not been fully retracted, it will not rest completely in the cradle. 5 Turn the mast hold-down latch handle counterclockwise and push into the lock. 6 Turn the latch handle clockwise until the handle points straight down. The latch should turn freely without binding or hesitation. Grounding Rod Attachment A grounding rod attachment is located next to the generator under the cover on the control panel side of the machine. After Each Use 1 Select a safe parking location—firm, level surface, clear of obstructions and traffic. 2 Remove the key OR lock the control panel to secure from unauthorized use. To Store the Lamp Fixtures (Standard models) Note: Do not touch hot lamp fixtures. Make sure the lights are turned off and the lamp fixtures have cooled down before touching. For each lamp fixture: 1 Disconnect the electrical plug and cap the receptacle socket. 2 Remove the safety pins and release the latches. 3 Pull the lamp fixture up and off the mounting bracket. 4 Slide the lamp fixture onto the channels located under the covers. 5 Close and secure the covers before transport. Genie TML-4000 and TML-4000N Part No. 97600 Third Edition • Second Printing Operator's Manual Towing 1 Make sure the mast hold-down latch is securely locked in place. 2 Make sure the covers are closed and secured. 3 Push to release the lock handle on each of the side outriggers and place in the stowed position. Make sure the spring pins lock the outriggers securely in place. 4 Raise the tongue of the machine by turning the tongue outrigger jack handle. 5 Position the transport vehicle under the coupler on the tongue of the machine. 6 Open the latch on the coupler. 7 Turn the tongue outrigger jack handle to lower the tongue and raise the outrigger foot pad off the ground. 8 Close the latch on the coupler. 9 Rotate the tongue outrigger to the stowed position and secure with the lock pin. 10 Attach the safety chains (if required). 11 Connect and test the trailer lights. Towing Information Use the ...

Эта инструкция также подходит к моделям:
Электрогенераторы - TML-4000 (846.53 kb)
Электрогенераторы - TML-4000 (846.53 kb)
Электрогенераторы - TML-4000 (846.53 kb)
Электрогенераторы - TML-4000N (846.53 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории