Please refer to Table 4-1 for fault codes: The Codes are listed in order of hierarchy. For example: If during cooking the oven experiences an F1 and F2 fault, the oven will only report a F1 fault since the software will halt all actions upon discovering the F1 fault. In addition if a fault is detected the fault counter will increment. If the fault is cleared the fault counter will not de-increment. View Fault Codes To view the Fault Log, press the “4” and “6” keys simultaneously in the Off State. The oven will display all logged faults. See Figure 4-1. Each Fault Register will log up 255 instances before rolling back to zero. The Cook Count will log up to 65,535 Cook Cycles. Note: In order for the Control to log a Cook Cycle, the oven must complete the 1st Event of any given recipe. If a Recipe only has 1 Event, the oven must complete the entire Cook Cycle in order to count the Cook Cycle. F1BLOWERF2LOWTEMPF3MAGCURRF4MONITORTESTC3AD_VCC XX°F HX XX°F COOK FAULTS 0000 Figure 4-1: Fault Fault Code Introduction: Note: To reset Fault Counter, Press the “0” key. LOW MAG CURR (HV BREAKDOWN) or F3 MAG CURR – the magnetron transformer is drawing less than 7 amps. The normal current draw is approximately 9 amps. The current draw is being monitored by the control board which has a current transformer mounted on it. See section 6 LOW COOK TEMP or F2 LOW TEMP– the temperature set for the C3 SERIES is not being maintained within 84oF (46oC) differential of the Cook Chamber Setpoint. It is referenced by the cook chamber type K thermocouple. Note: It may also be controlled by the heat exchanger thermocouple. See section 5 MAG OVER TMP or F5 MAG TEMP– the snap disk on the magnetron has overheated and has tripped. Reference Chpt. 9 BLOWER STATUS or F1 BLOWER – The control board is not receiving the proper output from the convection (blower) motor speed control. Reference Chpt. 8 ELEC OVR TMP (EC TMP HIGH) or F6 EC TEMP – The electronics compartment thermocouple connected to the control board has detected a temperature above 140.F (60.C). Reference Chpt. 6 OVEN DOOR OPEN – (during cook cycle) the cooking door has been opened during a cook cycle and has not been closed properly. DOOR MONITOR or F4 MONITOR: --The control board senses that the Cook Door Monitor Switch is out-of-sequence with the Primary and/or Secondary Door Switches. Reference Chpt. 7 HX RISE LOW -HX (Heater) Temperature has failed to rise 14.F (~8.C) F in 30 seconds. Reference Chpt. 8 NOTE: Some error codes may be different or no longer available or current. The following list details all error codes created since C3/AB, C3/C, C3CMulti and C3/AB-Multi no exceptions. 4-2 Theory of Operation Fault Code Messages Matrix Old Error Code New Error Code Warm- Up While Cooking Self- Test Reference Chapter BLOWER STATUS F3 BLOWER X X X 8 LOW COOK TMP F2 LOW TEMP X 8 LOW MAG CURR F3 MAG CURR X X 9 DOOR MONITOR F4 MONITOR X 7 MAG OVER TMP F5 MAG TEMP X X X 9 ELEC OVR TMP F6 EC TEMP X X X 6 HX RISE LOW Same X X 8 THERMO OPEN Same X X X 8 OVEN DOOR AJAR Same X X X 7 EC TEMP HIGH F6 EC TEMP X X X 6 CLOSE OVEN DOOR same X X X 7 TABLE 4-1 Notes: 1. All Fault Codes listed in BOLD will terminate a Cook Cycle upon discovery. 2. Any fault occurrence during Cook mode will be logged in the Fault Counter. 3. ELEC OVR TMP/EC TEMP HIGH/F6 fault code will not terminate a cook cycle, however it will alert the user of a possible air circulation problem (Page 6-10) 4-3 CHAPTER 5 TEST TurboChef Technologies, Inc. C Series Test Mode TO ENTER TEST FUNCTION MODE 1. From the standby mode, press and hold both BACK and ENTER keys simultaneously. 2. The display reads: ENTER ACCESS CODE 3. Use the NUMERIC keypad to enter the following access code: 9-4-2-8 (Older Ovens 8-3 -1 -7) 4. Press the ENTER key. TEST FUNCTION OPTIONS The test screen displays the CC (cook cavity) and HX (heat exchange) temperature at the top of the screen. The control displays page one of the test function options. Press the DOWN ARROW key to display page two of the test functions options. To access a test function, press the corresponding soft key repeatedly. Blower Speed The BLOWER key increments the blower speed in 10% steps. When the blower speed is 100%, the next press sets the speed to 0%. Electronic Compartment Temperature The .ELEC key displays the temperature inside the electronic enclosure. Self Test Function The STEST key initiates a self–test function to test all major components of the oven. Press the L4 key once to run the Self Test. Press the BACK key to return to the standby mode. Heater Test The HEATER key turns the heater on or off. If the heaters are on, pressing the key turns the heaters off. If the heaters are off and the maximum (HX) temperature (900.F) is not exceeded, pressing the HEATER key turns the heaters on. If the blower speed is 0, the blower speed is set to the Idle Airflow. Magnetron The MGTRON key is a press and hold key to test the magnetron. If the magnetron filaments are off when the MGTRO...

Эта инструкция также подходит к моделям:
Электрические печи - C3/AB (3.24 mb)
Электрические печи - C3/CMulti (3.24 mb)
Электрические печи - C3Multi (3.24 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории