Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Alto-Shaam, модель 7.14

Производитель: Alto-Shaam
Размер: 2.1 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• CTC sensor is damaged. • 4-point CTC sensor is activated, but 1-point CTC sensor is installed. • Cable connection of CTC sensor is damaged. • Hardware problem on control unit (SM). E23 Steam Gen Probe Fault ES units only: Activated if the steam generator probe (B-4) is interrupted. ESi units only: • Activated if the position of personality jumper on X-3 is incorrect. • Activated if the position of B-4 jumper is incorrect. • Connection issue at B-4 probe. • Faulty B-4 probe. • Jumper on X-3 is imperly positioned. Should be between 2-8 or, if it is a smoker, between 2-9. • Jumper on X-6a is improperly positioned. Should be between 13-14. E24 Bypass Probe Fault Activated if the bypass probe (B-5) is interrupted. • Connection issue at B-5 probe. • Faulty B-5 probe. E25 Condensate Probe Fault Activated if the condensate probe (B-3) is interrupted. • Connection issue at B-3 probe. • Faulty B-3 probe. E26 Steam Gen Safety Probe Fault Activated if the steam generator safety probe (N-8) is interrupted. • Connection issue at N-8 probe. • Faulty N-8 probe. E27 Excess Steam Gen Safety Temp Activated if the steam generator safety probe (N-8) measures a temperature in excess of 266°F. ESi units only: • Activated if the position of N-8 jumper is incorrect. • Problem with water level probe. • Scale build-up inside steam generator. • Steam element contactor is stuck. • Connection issue with N-8 probe. • Faulty N-8 probe. • Jumper on X-6b is improperly positioned. Should be between 1-2. ELECTRIC COMBITHERM — INSTALLATION MANUAL #MN-28677 PG. 27 ® ERROR CODES COMBITHERM ERROR CODES AND REASONS (continued) Error Code Display Shows When does the error occur? Possible reason E29 Probe Short to Frame Activated if one or more of the temperature sensors were connected to GND for 5 seconds. • Connection issue at any of the temperature sensors. • Temperature sensor shorted to ground/faulty. E34 DE (Drain) Pump Failure Activated if water level did not drop below the low level sensor in the generator during a steam generator flush. • Problem with water level probe. • Scale build-up inside steam generator. • Scale plugging drain pump. • Faulty drain pump. E35 Venting Error Activated when vent switch reads open (vent closed) when it should be closed (vent open), or when it reads closed (vent open) when it should be open (vent closed). • Alignment issue between motor cam and micro switch. • Connection issue at micro switch. • Connection issue at control. • Faulty vent switch. • Faulty vent motor. E36 Steam Temp High Activated when oven temperature probe (N-6) measures a temperature in excess of 395°F when running in Steam or Combi mode. • Water supply is shut off while unit is running in Steam or Combi mode. • Plugged or faulty Y-1 solenoid. • Obstruction between Y-01 solenoid and water inlet. E80 ID Error Control is unable to detect whether unit is gas or electric. • Connection issue at X-3 personality jumper. • Faulty control. E81 Program Memory Error Temperature value or time value of a program step is not allowed. • Program was generated in °C and control has been switched to °F. • Program was generated in °F and control has been switched to °C. E82 WP Error Temperature value or time value of current cooking algorithm is out of allowed array. • Delete program and reinstall. E83 Algo Error Cooking algorithm sent by operating module (BM) is unknown to control unit (SM). • Software versions of control unit and operating module are incompatible. • Software error in operating module. E96 Connection Error No or bad communication between control unit (SM) and operating module (BM). • Connection issue at ribbon cable on display or relay board. • Faulty ribbon cable. • Software versions of control unit and operating module are incompatible. ELECTRIC COMBITHERM — INSTALLATION MANUAL #MN-28677 PG. 28 COMBITHERMCOMBITHERM ® ERROR CODES EMERGENCY OPERATION In the event of an error code, the Combitherm may be operated on a limited basis. Error conditions under which continued operation can be conducted are indicated by “Yes” in the chart shown below. When the oven malfunctions, an error code will appear in the display. PRESS THE START KEY TO ACKNOWLEDGE THE ERROR. The keys that begin to flash represent operational modes that are still usable. SELECT AND PRESS ONE OF THE COOKING MODES INDICATED. The oven control will only respond to the mode keys that are flashing. SET THE OVEN CONTROLS AS IF OPERATING UNDER NORMAL CIRCUMSTANCES. Depending on the error code involved, oven function, such as temperature range, may be limited. PRESS THE START KEY TO BEGIN THE COOKING PROCESS. PRESS THE START KEY WHEN THE TIMER EXPIRES. When the oven fault is corrected, the Combitherm will return to normal Operation. CONTINUED OPERATION UNDER ERROR CONDITIONS Error Code Display Shows ES ESi Steam Mode Combination Mode Convection Mode Retherm Mode E01 Low Water Yes No No No To 365°F No E02 Control Temp High Yes Yes Yes To 284°F To 284°F To 284°F E03 Fan Malfunction No ...

Эта инструкция также подходит к моделям:
Электрические печи - 6.10 (2.1 mb)
Электрические печи - 10.10 (2.1 mb)
Электрические печи - 10.18 (2.1 mb)
Электрические печи - 20.20 (2.1 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории