Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Alto-Shaam, модель 10.10

Производитель: Alto-Shaam
Размер: 2.1 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Depending on the error code involved, oven function, such as temperature range, may be limited. PRESS THE START KEY TO BEGIN THE COOKING PROCESS. PRESS THE START KEY WHEN THE TIMER EXPIRES. When the oven fault is corrected, the Combitherm will return to normal Operation. CONTINUED OPERATION UNDER ERROR CONDITIONS Error Code Display Shows ES ESi Steam Mode Combination Mode Convection Mode Retherm Mode E01 Low Water Yes No No No To 365°F No E02 Control Temp High Yes Yes Yes To 284°F To 284°F To 284°F E03 Fan Malfunction No No — — — — E04 Aux Fan Fault Yes Yes Yes To 284°F To 284°F To 284°F E11 Excess Oven Temp Yes Yes No No No No E13 Excess Steam Gen Temp Yes No No No No No E15 Excess Condensate Temp Yes Yes No No To 356°F No E21 Oven Probe Fault Yes Yes 212°F only No No No E22 Core Temp Probe Fault Yes Yes Yes Yes Yes Yes E23 Steam Gen Probe Fault Yes No Yes Yes Yes Yes E24 Bypass Probe Fault Yes Yes To 210°F No Yes No E25 Condensate Probe Fault Yes Yes Yes To 356°F To 356°F To 320°F E26 Steam Gen Safety Probe Fault Yes No Yes Yes Yes Yes E27 Excess Steam Gen Safety Temp Yes No No No No No E29 Probe Short to Frame Yes Yes No No No No E34 DE (Drain) Pump Failure Yes No Yes Yes Yes Yes E35 Venting Error Yes Yes Yes Yes Yes Yes E36 Steam Temp High No Yes No No Yes No E80 ID Error Yes Yes Yes Yes Yes Yes E81 Program Memory Error Yes Yes Yes Yes Yes Yes E82 WP Error Yes Yes Yes Yes Yes Yes E83 Algo Error Yes Yes Yes Yes Yes Yes E96 Connection Error Yes Yes No No No No ELECTRIC COMBITHERM — INSTALLATION MANUAL #MN-28677 PG. 29 ® VENTLESS HOOD OPTION COMBITHERM The Ventless Hood option is factory installed directly on the top of the Alto-Shaam Combitherm oven. The hood is designed to vent clean air back into the kitchen, filtering vapors and grease. A high-power fan draws steam and fumes into the hood intake and out the top surface exhaust vent. Fumes and vapors are circulated through filters draining the condensation through a drain at the rear of the hood. An activated charcoal filter cleans the air before venting it out the top of the hood. CONDENSATE DRAIN A ventless hood condensate drain line to the floor drain must be installed. The 3/4" NPT thread connection is found at the back of the hood. The drain line must always be a positive gradient away from the Combitherm. OPENING MECHANISM Using a coin or screwdriver, turn to open; reverse procedure to close and latch. Hood and oven will not operate unless this is closed properly. ELECTRIC COMBITHERM — INSTALLATION MANUAL #MN-28677 PG. 30 COMBITHERMCOMBITHERM ® VENTLESS HOOD OPTION OPERATION . Turn the ventless hood power knob "ON". . Wait five seconds, then press the "COMBI RESET" button. . Turn the Combitherm oven power "ON". There are a number of safety features incorporated into the operation of the hood which are directly related to the interaction of hood function and the operation of the combi oven/steamer. INDICATOR LIGHTS If the indicator lights do not illuminate, the filters may be missing or not properly aligned. Check them for proper positioning. Ventless hood and oven will not operate unless the hood is closed properly. INTERLOCK SWITCHES CHARCOAL FILTER SWITCH, GREASE FILTER SWITCH: Prevents hood and oven operation if any filter is not in place or is improperly installed. FAN PRESSURE SWITCH: Prevents Combi oven operation if hood fan is not operating or if the filters are more than 25% blocked. TIMED LATCHING MECHANISM In order to evacuate steam and grease-laden air from the oven interior, this mechanism prevents the operator from fully opening the oven door for 25 seconds to one minute. The mechanism automatically disengages at the end of a pre-set time allowing full door extension. RESET SWITCH The reset has to be used if the Combitherm oven is turned on before the hood or if the hood was opened. It resets the pressure switch circuit and provides power to the Combitherm control circuit. This switch must also be used to reset hood controls after any problem with the filters, or the improper latching of the ventless hood door. ELECTRIC COMBITHERM — INSTALLATION MANUAL #MN-28677 PG. 31 ® VENTLESS HOOD OPTION COMBITHERM CHARCOAL FILTER FI-24114 (VHES-5) FI-24102 (VHES-10) CLEANING AND MAINTENANCE To ensure optimum performance from the ventless hood, it is important to establish and maintain a regular cleaning and maintenance schedule. To help maintain the protective film coating on polished stainless steel, clean the exterior of the cabinet with a cleaner recommended for stainless steel surfaces. Spray the cleaning agent on a clean cloth and wipe with the grain of the stainless steel. CHARCOAL FILTER The charcoal filter should be inspected for contaminant's on a regular basis. Replacement must be made at a minimum of three month intervals — more often if heavy contaminant's are visible or if the filter no longer controls odors. To remove the filter, pull and slide out while holding the bottom housing. When replacing the filter, make certain the air flo...

Эта инструкция также подходит к моделям:
Электрические печи - 6.10 (2.1 mb)
Электрические печи - 10.18 (2.1 mb)
Электрические печи - 20.20 (2.1 mb)
Электрические печи - 7.14 (2.1 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории