Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации American Power Conversion, модель 3644A

Производитель: American Power Conversion
Размер: 275.5 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The range NEW= of the address is from 0 to 31. 2.3.6.8 Lock the keypad After you locked the keypad, you must enter the correct password to unlock it, then you can use the number keys and the ROTARY knob. This function is for the safety of the using of power supply. When you select the KEY LOCK function, the LCD will display as: Users can enter 4 numbers or letters as the password by pressing the number button or by using ROTARY ENTER PASSWORD knob to and keys to change the number or ASCII number which will be your password, and confirm the password by pressing “Enter” button. 2.3.6.9 Clear saved parameters When you select CLEAR SAVE DATA function, the LCD will display as: “*” refers to the serial number of the saved parameters. CLEAR * 2.3.6.10 Exit Select “Exit” to exit the menu. 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL Chapter 3 System Installation of PowerMS Software 3. 1 System Installation 3.1.1 Put the disk into the CDROM driver. Then select the setup powerMS and the initial diagram as in Fig. 3-1 will be displayed. Fig 3-1 The Installation Initial Interface 3.1.2 Then it will enter the interface as in Fig. 3-2. Press “NEXT” to continue. Fig 3-2 The Installation Interface 2 3.1.3 In Fig. 1-3, there is some explanation to some products’ introduction. Read it and press “YES” to continue, otherwise there will be no way to install. Fig 3-3 The Installation Interface 3 3.1.4 In Fig. 3-4, click “BROWSE” to select installation directory path. The default directory path is “C: \Program Files\Array\PowerMS” Fig 3-4 The installation Interface 4 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 3.1.5 In Fig. 3-5, users may select the installation type. Generally, select “TYPICAL” and click “NEXT” to continue. Fig 3-5 The Installation Interface 5 3.1.6 In Fig. 3-6, enter the file folder’s name and the default name is “POWERMS”. Generally it is not needed to enter and it is just need to click “NEXT”. Fig 3-6 The Installation Interface 6 3.1.7 Click “NEXT” and the installation system will enter the files’ copy state. Please wait patiently for the end of the files’ copy. Then the PowerMS system installation finished. Fig 3-7 The Installation Interface 7 3.2 System Start 3.2.1 In Fig. 3-8, select the file folder of “Start | Program | Array”. And then click the “PowerMS” in the menu. Fig 3-8 The System Start Interface 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL 3.2.2 Enter the initial interface as shown in Fig. 3-9. Fig 3-9 The System Start Diagram 3.2.3 Wait for the end of the system initialization and then it will be the main interface as shown in Fig. 310. Fig 3-10 The PowerMS Main Interface Explanation: 1. Once the PowerMS system is started, it will be automatically in the minimized state. And this time the icon is in the state bar on the desk. Click the right key of the mouse on the icon, the menu as shown in Fig. 3-11 will be displayed. Fig 3-11 “Show”: Show the interface. “Hide”: Hide the interface. “Start Communicate”: Start the communication. “Stop Communicate”: Stop the communication. “About PMS”: Show the help contents. “Exit System”: Close the system. 3.3 System Uninstallation Select “ ”under the program file folder to uninstall it. 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL Chapter 4 The introduction of main functions 4.1 The Definition of the Power Supply Select the function item and then the interface as shown in Fig. 4-1 will be displayed. Fig 4-1 The Power Definition Interface Add: Select “Add” in the function items and input the contents of each item. After the set of the input, select “Save” to save it. Delete: Select the POWER record to be deleted in the table and then select “Delete”. Finally select “Save” and it will be OK. Modify: Select the POWER record to be modified in the table and then select “Modify” to modify it. After the modification, select “Save” and it will be OK. Query: Select “Query” and then wait for the name of the power supply to be queried. Show: Select “Show” and it will show all the records. Print: Select “Print” and it will print all the current records. Parameter Explanation Parametrer Explanation Range Remarks Power Name Name Of the Power Supply Must be Input Current Up The Max Current 0~5A/ 0~3A0~1.5A Must be Input Power Up The Max Power 0~90W/0~108W/0~108W Must be Input Voltage Configure The Max Voltage 0~18V/0~36V/0~72V Must be Input Configure ID The ID Number No Consideration Notes: When selecting the “Add” function item to add POWER, the name and address of the POWER cannot be repeated. After selecting the inputs, click “OK” and the dialogue frame as shown in Fig. 4-2 will be displayed. In Fig.4-3, select “YES” and the system will close and restart. 3600 Series Programmable Power Supply VERSION 2.0 2004.6 3600 SERIES USER MANUAL Fig 4-2 System Prompt the restart 4.2 The COM Port and Lower Machine (Power Supply) Address Set L...

Эта инструкция также подходит к моделям:
Источники питания и БП - 3646A (275.5 kb)
Источники питания и БП - 3644A (275.5 kb)
Источники питания и БП - 3645A (275.5 kb)
Источники питания и БП - 3646A (275.5 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории