Инструкция по эксплуатации American Power Conversion, модель 1000XL

Производитель: American Power Conversion
Размер: 361.16 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


PLACEMENT 0.- 40.C (32.-104.F) 2.5cm (1in) 0-95% Relative Humidity 1 Connecting Equipment and Power to the UPS SMART-UPS REAR PANEL 230V MODELS 120V/100V MODELS 1. Plug in the battery connector . 2. Connect equipment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer draws significantly more power than other types of equipment and may overload the UPS. 3. Add any optional accessories to the Smart-Slot . 4. Using the power cord, plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. • 230V models: A utility connector plug is included for use on servers with permanently attached power cords. • 120V/100V models: The power cord is permanently attached to the rear panel of the UPS. 5. Turn on all connected equipment. To use the UPS as a master ON/OFF switch, be sure all connected equipment is switched ON. The equipment will not be powered until the UPS is turned on. 6. To power up the UPS press the button on the front panel. • The UPS charges its battery when it is connected to utility power. The battery charges to 90% capacity during the first three hours of normal operation. Do not expect full battery run capability during this initial charge period. • 120V Models: Check the site wiring fault LED located on the rear panel. It lights up if the UPS is plugged into an improperly wired utility power outlet. Refer to Troubleshooting in this manual. 7. For additional computer system security, install PowerChutePlus® UPS Power Management and Diagnostic Software. 2 BASIC CONNECTORS Power management software and interface kits can be used Serial Port USB Port with the UPS. Use only interface kits supplied or approved by APC. Use the APC supplied cable to connect to the Serial Port. DO NOT use a standard serial interface cable since it is incompatible with the UPS connector. Both Serial and USB Ports are provided. They cannot be used simultaneously. External Battery XL models: Use the battery pack connector to connect optional external Pack Connector battery pack(s). These units support up to ten external battery packs. See the APC web site, for the correct external battery pack model number for your UPS. The UPS features a transient voltage surge-suppression (TVSS) screw for TVSS Screw connecting the ground lead on surge suppression devices such as telephone and network line protectors. When connecting grounding cable, disconnect the unit from the utility power outlet. 3 2: OPERATION SMART-UPS FRONT PANEL Power On Power Off Load Battery Charge Online The online LED illuminates when the UPS is supplying utility power to the connected equipment. If the LED is not lit, the UPS is either not turned ON, or is supplying battery power. This LED illuminates to indicate the UPS is compensating for a high utility voltage. AVR Trim 4 AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. On Battery When the on battery power LED is lit the UPS is supplying battery power to the connected equipment. When on battery, the UPS sounds an alarm—four beeps every 30 seconds. Overload The LED illuminates and the UPS emits a sustained alarm tone when an overload condition occurs. Replace Battery Failure of a battery self-test causes the UPS to emit short beeps for one minute and the replace battery LED illuminates. Refer to Troubleshooting in this manual. Battery Disconnected The replace battery LED flashes and short beep is emitted every two seconds to indicate the battery is disconnected. Automatic Self-Test The UPS performs a self-test automatically when turned on, and every two weeks thereafter (by default). During the self-test, the UPS briefly operates the connected equipment on battery. If the UPS fails the self-test, the replace battery LED lights and immediately returns to online operation. The connected equipment is not affected by a failed test. Recharge the battery for 24 hours and perform another self-test. If it fails, the battery must be replaced. Manual Self-Test Press and hold the button for a few seconds to initiate the self- test. On Battery Operation The Smart-UPS switches to battery operation automatically if the utility power fails. While running on battery, an alarm beeps four times every 30 seconds. Press the button (front panel) to silence the UPS alarm (for the current alarm only. If the utility power does not return, the UPS continues to supply power to the connected equipment until the battery is exhausted. If PowerChute is not being used you must manually save your files and power down before the UPS turns off. DETERMINING ON BATTERY RUN TIME UPS battery life differs based on usage and environment. It is recommended that the battery/batteries be changed once every three years. See the APC web site, for on battery run times. 5 3: USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE MADE THROUGH SUPPLIED POWERCHUTE SOFTWARE OR OPTIONAL SMART SLOT ACCESSORY CARDS. FUNCTION FACTORY DEFAUL...

Эта инструкция также подходит к моделям:
Источники питания и БП - 230VAC (361.16 kb)
Источники питания и БП - 120VAC (361.16 kb)
Источники питания и БП - 1500VA (361.16 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории