Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации FMI, модель FVF18PW

Производитель: FMI
Размер: 409.68 kb
Название файла: a3a8e731-1e71-4574-cd9b-39a7aaaf7138.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Combustible Material Noncombustible Material Hearth Combustible Material5” Min. Underside of Mantel Shelf All minimum distances are in inches Log Set 24"/30" Models 18" Model Top of Fireplace Underside of Mantel Shelf All minimum distances are in inches Log Sets All Models Top of Fireplace Opening Continued 105194 9 FIREPLACE MANUFACTURERS INCORPORATED UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note:When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material. If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode. 1. The fireplace does not meet the clearance to combustibles requirements for vent-free operation. 2. State or local codes do not permit vent- free operation. 3. You prefer vented operation. If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 21). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory. See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times. Area of Various Standard Round Flues Diameter (ins.) Area (sq. ins.) 5" 6" 7" 8" 20 sq. inches 29 sq. inches 39 sq. inches 51 sq. inches Chimney Minimum Permanent Height (ft.) Flue Opening (sq. ins.) 6' to 15' 39 sq. inches 15' to 30' 29 sq. inches Masonry Fireplace Figure 10 - Attaching Damper Clamp INSTALLING HEATER BASE ASSEMBLY Damper Damper Clamp Damper Clamp Damper Damper CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty and safety information. WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak. WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and controls being damaged. Raise fireplacefloor with noncombustible material. Make sure material is secure. CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assembly by grates. Manufactured Fireplace IMPORTANT:Make sure the heater burner is level. If heater is not level, heater will not work properly. Installation Items Needed • hardware package (provided with heater) • approved flexible gas hose (not provided) (if allowed by local codes) • sealant (resistant to propane/LP gas, not provided) • electric drill with 3/16" drill bit (metal or masonry as applicable) • flathead screwdriver 1. Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas control. Connect approved flexible gas hose to gas control fitting in heater (see Figure 11). IMPORTANT: Hold gas fitting with wrench when connecting flexible gas hose. 2. Locate two masonry screws in hardware package. Fitting Flexible Gas Hose (if allowed by local codes) Figure 11 - Attaching Flexible Gas Hose to Heater 10 105194 OWNER’S MANUAL INSTALLATION Continued 3. Place heater base in fireplace. 4. Place logs in their proper position on heater base (see Installing Logs, page 13). 5. Center heater base and logs front-toback and side-to-side in fireplace. 6. Carefully remove logs without moving heater base. 7. Mark screw locations through one hole on each side of the mounting bracket (see Figure 12). If installing in a brick- bottom fireplace, mark screw locations in mortar joint of bricks. 8. Remove heater base from fireplace. If installing optional control accessories, do so at this time. Follow all directions provided with accessory. 9. Drill holes at marked locations using 3/16" drill bit. 10. Attach base assembly to fireplace floor using two masonry screws (in hardware package). Masonry Screw Figure 12 - Attaching Base Assembly to Fireplace Floor Mounting Flange AUTOOFFON OFF PILOT ON HI LO CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. Installation Items Needed Before installing heater, make sure you have the items listed below. • external regulator (supplied by installer, see above) • piping (check local codes) • sealant (resistant to propane/LP gas) • equipment shutoff valve * • test gauge...

Эта инструкция также подходит к моделям:
Газовые нагреватели - FVF24PW (409.68 kb)
Газовые нагреватели - FVF30PW (409.68 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории