Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации LG, модель NL-7000 AC

Производитель: LG
Размер: 124.3 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


3035: Open battery box (inside door) and insert new batteries. If the batteries have not been changed in time and the tension does not suffice to cancel the lock‘s blocking feature, a new 9V DURACELL ALKALINE battery can be pressed onto the contacts on the entry, until the code has been entered and the entry is rotated. When Time Delay is programmed, use a battery clip (on general sale). Black upper position, red lower position. When connected to the alarm equipment through the interlock device “SP“ then the power supply is secured from this place. · Change the manager code immediately · Do not use personal data (birth date) as a code · Keep the code from unauthorised use 1 x short signal enter confirmation 2 x short signal valid code entered 3 x short signal wrong code, not accepted 6 x short signal remote disable, blocked by the alarm equipment LED signal each 10sec. 1 flashing blocking time after a wrong tries LED signal each 2sec. Time delay before opening is running Alternate LED and acoustic signals Time window for opening is running A series of triple signals, ca. 3seconds: Low battery Still possible ca. 10 openings. According to the battery capacity there may be also less signals therefore the battery change should be made also in case of double signals Use 9V DURACELL ALKALINE batteries only! LG 39E Combogard EN 2 Revise: 1 Datum: 16-02-05 Kantooradres: Postadres: Vlijtstraat 40 Postbus 127 NL-7005 BN Doetinchem NL-7000 AC LA GARD Locks BV H.R. te Arnhem nr: 09087869 Tel: (+31) 314 376 876 E-mail: info@lagard.nl Internet: BTW nr: NL 8038.72.987.B01 Fax: (+31) 314 376 878 Manual programming LG 39E Multi User Factory Mode The lock maybe mounted in the factory mode. It opens when (Pre-Setup-mode) pressing key “1” and it sends a silent alarm signal. The advantage is that there is only 1 version storage and an easy use during mounting. Exit the Factory-Mode Keep pressed the key “0” until the double signal (4-5 seconds). Now the manager code is 555555. Code length and program selection The code length and program selection are made with the (6-9 digit code length is possible) function “8” in a group of 2 digits. The first digit is the code length and the second one is the program number. Program 0 = Manager mode (operation with parallel code) Program 1 = Manager mode with delay override Program 2 = Operation with two codes Program 3 = Two code operation with delay override Program 4 = Manager mode with alarm Program 5 = Manager with alarm and with delay override Program 6 = Two code operation with alarm Program 7 = Two code operation, alarm and delay override Programming Enter the manager code “555555” and keep pressed the (function 8) last number until the double signal is repeated (LED is on) and enter “8”. Enter the group of 2-digits (code length and program number) double signal and repeat the group for confirmation (double signal). In case of the 7-digit codes the manager code is 7x “5”. Install (Enable) user (function 1) Enter manager-code and keep last digit pushed until LED stays on. Press „1“ (double signal) and enter user-ID Nr. f.i. „1“ (double signal). Enter user code (double signal) and to confirm, enter the code again. Double signal and LED extinguished. In case a new code is not accepted (3-time-signal), this code is too similar to an already existing code. Select new code. NOTE: Users who are not installed in this stage will be blocked after changing the manager code! Program “freeze” After changing the manager code the program is „frozen“ and the program settings can only be changed after a reset to Factory Mode. Reset to Factory Mode In case the manger code is lost or the setting of the lock has to be changed, a reset can be executed by means of the RESET-BOX (PN#6066). Unplug battery from the lock or entry. Push the "0" button for ca. 3 minutes (or leave it for 10minuts powerless) and plug the RESET-BOX in the BAT- connection of the lock. Wait until a longer signal. (0,5 sec) The Reset-Box requires a connected 9V-DURACELL ALKALINE-battery. The lock is in FACTORY MODE. Disconnect Reset-Box and plug battery back again. Lock opens with “1”. Safety notice: Do not assign code to the users of no use for the time being. Remove the codes. (Function 3 and user number) LG 39E Combogard EN 3 Revise: 1 Datum: 16-02-05 ...

Эта инструкция также подходит к моделям:
Двери и окна - NL-7005 BN (124.3 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории