|
Фрагмент инструкции
SUB-ZERO WINE STORAGE The importance of the installation of the Sub-Zero Wine Storage unit cannot be overemphasized. Installation should be done by a qualified installer. Before you begin the installation process, it is recommended that you read this entire Installation Instructions book. There are key details that you should take special care to observe during the installation. By reading these instructions carefully, you will make the installation process easier, problem-free and, most importantly, safe. Any questions or problems about the installation should be directed to your Sub-Zero dealer or the Sub-Zero Customer Service Department at 800-222-7820. You can also visit our website at subzero.com. SUB-ZERO® is a registered trademark of Sub-Zero, Inc. As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Sub-Zero equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problem- free installation. MODELS 424 AND 424FS INSTALLATION MODELS 424 AND 424FS SITE PREPARATION The Sub-Zero Model 424FS wine storage unit is designed to be attractive in a stand alone setting. It can also be slid into surrounding cabinetry with clearance dimensions slightly different than the standard built-in Model 424. Make sure that the finished rough opening where the Wine Storage unit is to be installed is properly prepared. Refer to the Installation Specifications illustration for rough opening dimensions, door swing clearance and electrical placement for Models 424 and 424FS. IMPORTANT NOTE: To operate properly, the door must open a minimum of 90 degrees. Use a minimum 3" (76) filler in corner installations to assure a 90-degree door opening. Allow enough clearance in front of the unit for full door swing. IMPORTANT NOTE: Make sure the floor under the unit is level with the surrounding finished floor. Do not load wine into the Wine Storage unit until the installation is complete. INSTALLATION SPECIFICATIONS 24" (610) ROUGH OPENING DEPTH TOP VIEW ROUGH OPENING WIDTH 24"(610) MODEL 424 243/8"(619) MODEL 424FS 151/2" (394) LOCATE ELECTRICAL WITHIN SHADED AREA E 41/2" (114) 21/2" (64) MODEL 424 ANTI-TIP BRACKET MODEL 424FS ANTI-TIP BRACKET FRONT VIEW MODELS 424 | 424FS 341/2" (876) ROUGH OPENING HEIGHT 341/4" (870) MINIMUM HEIGHT REQUIRED 237/8" (606) 44" (1118) DOOR CLEARANCE 26" (660) DOOR CLEARANCE 253/8" (644) 253/8" (645) NOTE: Door swing clearances are based on stainless steel door and handle dimensions. Dimensions in parentheses are in millimeters unless otherwise specified. MODELS 424 AND 424FS INSTALLATION MODELS 424 | 424FS ELECTRICAL REQUIREMENTS A 115 V AC, 60 Hz, 15 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance, is required. The power supply cord has a 3-prong grounding plug, which must be plugged into a mating 3-prong grounding-type wall receptacle. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation Specifications illustration on page 3. IMPORTANT NOTE: For Models 424 and 424FS, the electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Do not use an extension cord or two- prong adapter. Electrical ground is required on this appliance. HOME ALARM SYSTEM If a home alarm system is to be used, refer to Home Alarm Connections on page 8. In addition to operating power, the installer may also be required to supply a home automation system lead to the unit. This is for a low-voltage, low- current signal similar to door and window sensor signals. Common, normally open and normally closed contact configurations are provided. Three 1/4" (6) female spade connectors are located in the compressor compartment and are accessible behind the kickplate on Models 424 and 424FS. A minimum of 36" (914) of lead wire should be provided for each contact, exiting the back wall near the electrical outlet. UNPACKING AND MOVING Uncrate the unit, remove its wood base and discard the shipping bolts that hold the wood base to the bottom of the unit. Remove all packing materials and tape. IMPORTANT NOTE: Do not discard the kickplate, anti-tip bracket and hardware. These items will be needed for the installation. All roller-assembly wine shelves should be removed to reduce weight and prevent them from rolling. To remove, pull the shelf out...
Эта инструкция также подходит к моделям:Диспенсеры - 430/F (575.93 kb)
Диспенсеры - 430/O (575.93 kb)