Инструкция по эксплуатации Follett, модель C/E25HR400A/W

Производитель: Follett
Размер: 1.38 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Dispensers and Satellite-fill icemakers are supplied with a 2m (7ft) power cord. Ambient Air temp 38°C/100°F max. 10°C/50°F min. (best performance below 27.C/80°F) Water temp 32°C/90°F max. 4°C/40°F min. (best performance below 21°C/70°F) Water pressure 4.8 bar/70 P.S.I. max. .69 bar/10 P.S.I. min. Plumbing 25/50C with 25/50H with 25/50C with 25/50H with 25/50FB Satellite-fill Satellite-fill integral integral icemaker icemaker icemaker icemaker icemaker in base Dispenser drain1 3/4" FPT 3/4" ID tubing 3/4" FPT 3/4" ID tubing 3/4" FPT Icemaker drain1 3/4" MPT 3/4 MPT – – 3/4" MPT Dispenser water inlet2 3/8" push-in 3/8" push-in 3/8" push-in 3/8" push-in 3/8" push-in Satellite-fill IM water inlet2 3/8" push-in 3/8" push-in – – – Cond. inlet – w/c only 3/8" FPT 3/8" FPT 3/8" FPT 3/8" FPT 3/8" FPT Cond. drain – w/c only 3/8" FPT 3/8" FPT 3/8" FPT 3/8" FPT 3/8" FPT Note: Water shut-off recommended within 3m (10 feet) of dispenser. Drain to be hard piped and insulated, and maintain slope of at least 20mm per 1m run (1/4" per foot) of slope. All plumbing connections must be made in accordance with local building codes. Ventilation clearances Countertop and wall mount models with Satellite-fill icemaker (C/E25CR400A/W, C/E50CR400A/W, C/E25HR400A/W, C/E50HR400A/W) — none. 305mm (12") at top advised for service. Countertop and wall mount models with integral icemaker (C/E25CT400A/W, C/E50CT400A/W, C/E25HT400A/W, C/E50HT400A/W) — 153mm (6") at top. 153mm (6") each side advised for service. Freestanding models (C/E25FB400A/W, C/E50FB400A/W) — 102mm (4") at rear. 305mm (12") at top advised for service. 1 Includes adapter kit to 3/4" barb fitting and 6' 3/4" ID vinyl tube 2 Includes adapter kit – 6' 3/8" OD tubing and adapter to 1/2" BSP 5 Field Wiring: countertop and wall mount dispensers with Satellite-fill icemakers Model Electrical connection Current C25FB400A/W, C50FB400A/W E25FB400A/W, E50FB400A/W cord provided 220V 60Hz, 6.5 amp 230V 50Hz, 6.5 amp C25CT400A/W, C50CT400A/W E25CT400A/W, E50CT400A/W C25HT400A/W, C50HT400A/W E25HT400A/W, E50HT400A/W cord provided 220V 60Hz, 6.5 amp 230V 50Hz, 6.5 amp 220V 60Hz, 6.5 amp 230V 50Hz, 6.5 amp C25CR400A/W, C50CR400A/W E25CR400A/W, E50CR400A/W C25HR400A/W, C50HR400A/W E25HR400A/W, E50 HR400A/W cord provided 220V 60Hz 230V 50Hz 220V 60Hz 230V 50Hz dispenser: 1.5 amp ice maker: 5.0 amp 6 Installation procedures Before you begin • All dispensers must be installed level in both directions to ensure proper operation • Required ventilation and recommended service clearances: • Countertop and wall mount models with Satellite-fill icemaker (C/E25CR400A/W, C/E25HR400A/W, C/E50CR400A/W, C/E50HR400A/W) — none. 305mm (12") at top recommended for service • Countertop and wall mount models with integral icemaker (C/E25CT400A/W, C/E25HT400A/W, C/E50CT400A/W, C/E50HT400A/W) — 153mm (6") at top. 153mm (6") each side recommended for service • Freestanding models (C/E25FB400A/W, C/E50FB400A/W) — 102mm (4") at rear. 305mm (12") at top recommended for service • All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser. See counter cut-out on page 9 (Fig. 2) for bottom exiting utilities on units with and without drain pans. For installations where utilities will exit through back of dispenser, refer to back view drawings. • Wall mount models are designed for use above sinks or custom drain pans, and are not normally equipped with integral drain pans. Front of sink should be a minimum of 584mm (23") from back wall. Connection of utilities through the back for wall mount units is the same as shown in drawings for countertop models except that the drain pan is absent. • SensorSAFE dispensers are shipped with a plastic, protective film on sensor lenses. For proper operation, plastic film must be removed after installation. Installing freestanding dispensers 1. Carefully tip dispenser back to expose underside and block up in place. ! Do not tilt unit further than 30° off vertical plane. 2. Remove legs from shipping box (taped to drain pan of dispenser) and screw into dispenser bottom, taking care to seat legs securely against underside of dispenser. 3. Position dispenser in desired location and adjust legs to level in both directions. 4. Connect water supply to 10mm (3/8") OD push-in fitting on back of dispenser (Fig. 1A). 5. Remove 19mm (3/4") dispenser drain line plug from back of unit and discard. Connect separate drain lines to 19mm (3/4") FPT dispenser drain fitting (Fig. 1B), and 19mm (3/4") MPT icemaker drain fitting (Fig. 1C) on back of dispenser. 6. Run drain lines to wall or floor drain. Provide an air break between the drain lines and drain. If icemaker drain fitting is below an intended wall drain, a condensate pump must be used. 7. If icemaker is a water-cooled unit, connect water-cooled condenser supply line to 10mm (3/8") FPT condenser inlet fitting on back of dispenser (Fig.1D). Note: Do not run condenser supply water through icemaker wate...

Эта инструкция также подходит к моделям:
Диспенсеры - C/E25CR400A/W (1.38 mb)
Диспенсеры - C/E25HT400A/W (1.38 mb)
Диспенсеры - C/E50CR400A/W (1.38 mb)
Диспенсеры - C/E50HR400A/W (1.38 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории